| Plan Review Stops For Permit 05070342 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-28 |
Time |
06:52 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-28 |
Time |
06:38 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-13 |
Time |
08:11 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2005-08-13 |
Time |
08:11 |
Sent To |
PC |
|
| Notes |
| 2005-08-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05070342 | | | ADD: 228 ELWA PL | | | CONT:O/B ANTIC, MIROSLAW | | | TEL: (561)582-3522 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SITE PLAN:ALL INFORMATION, | | | DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME | | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. | | | CITY AMENDMENTS 104.2.1* | | | | | | 2) GENERATOR SLAB & ANCHOR REQUIREMENT | | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | | PLUS PROVIDE PLANS WITH THE INFORMATION | | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | | THE DEVICE REQUIRES WITHOUT LOAD | | | REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BEUSED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: | | | 104.2.1* ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-01 |
Time |
11:02 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2005-08-01 |
Time |
11:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-25 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-25 |
Time |
10:49 |
Sent To |
B |
|
| Notes |
| 2005-08-25 00:00:00 | TO "JWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
14:16 |
Sent To |
Z |
|
| Notes |
| 2005-08-18 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-20 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-20 |
Time |
15:18 |
Sent To |
E |
|
| Notes |
| 2005-07-20 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-11 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-11 |
Time |
15:49 |
Sent To |
Z |
|
| Notes |
| 2005-07-11 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-08-01 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-08-01 |
Time |
16:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-02 |
Time |
14:59 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-02 |
Time |
14:59 |
Sent To |
B |
|
| Notes |
| 2005-08-02 00:00:00 | GAS APPIED FOR NUMBER 05070983 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-24 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-24 |
Time |
17:40 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-20 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-20 |
Time |
12:49 |
Sent To |
I |
|
| Notes |
| 2005-07-20 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE DIMENISON OF | | | GENERATOR WITH SETBACK OF GENERATOR FROM | | | STRUCTURE AND PROPERTY LINE. | | | NOTE: GENERATOR CAN ONLY ENROACH 4FT | | | INTO SETBACK. | | | | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|