| Plan Review Stops For Permit 05070224 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-01-25 |
Time |
17:27 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-01-25 |
Time |
17:14 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-14 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-11-14 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05070224 | | | ADD: 250 S AUSTRALIAN AV# 600 | | | CONT: SHAKMAN | | | TEL: (561)750-8288 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)COMMENT# 3FROM THE PREVIOUS REVIEW: | | | EVEN THOUGH THIS AREA IS NOT NEW WORK | | | SEE 20% DISPROPORTIONATE COST. | | | 11-4.1.6(2) DUTY TO PROVIDE AN | | | ACCESSIBLE PATH OF TRAVEL TO ALTERED | | | AREAS SHALL BE DEEMED DISPROPORTIONATE | | | TO THE OVERALL ALTERATION WHEN THE COST | | | EXCEEDS 20 % OF THE COST OF THE ALTERA- | | | TION TO THE PRIMARY FUNCTION AREA. | | | (A)(I) AN ACCESSIBLE ENTRANCE | | | (II) AN ACCESSIBLE ROUTE | | | (III) AT LEAST ONE ACCESSIBLE REST- | | | ROOM FOR EACH SEX OR A SINGLE | | | UNISEX RESTROOM | | | (IIII) ACCESSIBLE TELEPHONE | | | (IV) ELEMENTS SUCH AS PARKING, STOR- | | | AGE OR ALARMS. | | | OFFICE 604 & 605 MISSING THE 18" | | | REQUIRED ON THE PULL SIDE,11-4.13.6 | | | MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 2) NEW WORK OFFICE# 623 IS STILL MISSING | | | THE REQUIRED CLEAR SPACE AT THE LATCH | | | SIDE OF DOOR WHEN THE DOOR IS PULLED | | | TOWARD YOU. SEE 11-4.13.6 | | | | | | 3) COMMENT# 5 FROM THE PEVIOUS REVIEW | | | DEALS WITH WOOD BACKING IN WALLS.SHEET | | | A-9 INDICATES WOOD BACKING IN | | | WALLS AND SUB-BUCKS.609.2.1 TYPE I AND | | | TYPE II CONSTRUCTION. PARTITIONS SHALL | | | BE CONSTRUCTED OF NONCOMBUSTIBLE | | | MATERIALS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-07 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-08-07 |
Time |
17:14 |
Sent To |
P |
|
| Notes |
| 2005-08-07 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05070224 | | | ADD: 250 S AUSTRALIAN AV# 600 | | | CONT: SHAKMAN | | | TEL: (561)750-8288 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | MISSING THE CERTIFICATE OF AUTHERIZATION | | | NUMBER ON PLAN, FAC 61G1-16,004 FL SS | | | 481.219. | | | | | | 3) OFFICE 604 & 605 MISSING THE 18" | | | REQUIRED ON THE PULL SIDE,11-4.13.6 | | | MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 4) SHEET A-3 MISSING EXIT LIGHTS AND | | | DIRECTIONALS.1016.1.1 ILLUMINATION OF | | | MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THIS SECTION FOR EVERY | | | BUILDING AND STRUCTURE.FOR THE | | | PURPOSES OF THIS REQUIREMENT, EXIT | | | ACCESS SHALL INCLUDE ONLY DESIGNATED | | | STAIRS, AISLES, CORRIDORS, RAMPS, | | | ESCALATORS AND PASSAGEWAYS LEADING TO | | | AN EXIT.FOR THE PURPOSES OF THIS | | | REQUIREMENT, EXIT DISCHARGE SHALL | | | INCLUDE ONLY DESIGNATED STAIRS, | | | AISLES, CORRIDORS, RAMPS, ESCALATORS, | | | WALKWAYS AND EXIT PASSAGEWAYS LEADING | | | TO A PUBLIC WAY. | | | | | | 5) SHEET A-9 INDICATES WOOD BACKING IN | | | WALS AND SUB-BUCKS.609.2.1 TYPE I AND | | | TYPE II CONSTRUCTION. PARTITIONS SHALL | | | BE CONSTRUCTED OF NONCOMBUSTIBLE | | | MATERIALS. | | | | | | 6) SHEET A-3 INDICATES THE USE OF | | | SIDELIGHTS FOR VARIOUS OFFICES BUT NO | | | MENTION OF SIDELIGHT.2405.2 HAZARDOUS | | | LOCATIONS.GLAZING IN AN INDIVIDUAL FIXED | | | OR OPERABLE PANEL ADJACENT TO A DOOR | | | WHERE THE NEAREST VERTICAL EDGE IS | | | WITHIN A 24-INCH (610 MM) RADIUS OF THE | | | DOOR IN A CLOSED POSITION AND WHOSE | | | BOTTOM EDGE IS LESS THAN 60 INCHES (1524 | | | MM) ABOVE THE FLOOR OR WALKING SURFACE. | | | | | | 7) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-03 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-03 |
Time |
07:43 |
Sent To |
FIRE |
|
| Notes |
| 2006-05-03 00:00:00 | REVISED | | | 1.1,1.2,2.0 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-27 |
Time |
20:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-27 |
Time |
19:58 |
Sent To |
|
|
| Notes |
| 2005-12-27 00:00:00 | PLEASE KNOWTHE NOC WHICH WAS SUBMITTED | | | BACK WITH PLANS IS VOID AS IT HAS | | | EXPIRED SINCE THE RECORDING OF 7/22/05 | | | PER FS 713.13(2). DVPALMER. | | | PLEASE KNOW THIS NOC JUST NEEDS TO BE | | | RE-RECORDED BEFORE PICKING UP PERMIT. | | | PER FS713.13(2), IF WORK HAS NOT | | | COMMENCED WITHIN 90 DAYS OF SUCH | | | RECORDING OF NOC, THEN THE NOC BECOMES | | | VOID. | | | | | | | | | ELECTRICAL PLANS STAMPED FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-10 |
Time |
23:05 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-09-10 |
Time |
22:58 |
Sent To |
|
|
| Notes |
| 2005-09-10 00:00:00 | *********UNSAT *********** | | | | | | | | | 1)NOTE: PLEASE SEE PERMIT APPLICATION | | | WAS NOT SUBMITTED BACK WITH PLANS, AND | | | MUST BE TURNED IN ASAP. | | | | | | 2)NOTE: PLEASE SUBMIT TWO COMPLETE SETS | | | WITH ALL SHEETS SIGNED DATED AND | | | SEALED BY THE ENGINEER OF RECORD. | | | PLEASE SEE ONE SET FOR ELECTRICAL SHEETS | | | ARE OK, HOWEVER 2ND SET IS NOT COMPLETED | | | FOR THIS. PLEASE ALSO SEE MISSING SIGNED | | | AND SEALED MECHANICAL SHEETS. FS | | | 471.025, FAC 61G15-23.002 | | | | | | 3)NOTE: PLEASE ALSO SEE IT WAS REQUESTED | | | ON THE PREVIOUS REVIEW TO "REMOVE" ALL" | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. | | | PLEASE SEE ONE SET STILL CONTAINS ALL | | | THE OLD/VOIDED SHEETS WHICH SHOULD BE | | | REMOVED. | | | PLEASE SEE THE OLD/VOIDED SHEETS SHOULD | | | BE PLACED BY THEMSELVES IN ONE SET AND | | | SUBMITTED WITH THE OTHER TWO FULL SETS | | | FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-15 |
Time |
18:01 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-07-15 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2005-07-15 00:00:00 | ********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE ONY ONE SET OF PLANS | | | FOR MP'S WERE SIGNED, DATED AND | | | SEALED. | | | PLEASE SEE FS 471.025 | | | THIS IS REQUIRED OF ALL TRADES AND FOR | | | ALL SHEETS WHEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWERS. | | | | | | 2)NOTE: PLEASE SEE BLDG REVIEW NOTES FOR | | | ARCHITECT'S TITLE BLOCK MISSING | | | INFORMATION AS REQUIRED UNDER FAC | | | 61G1-16.004, FS 481.219 | | | REQUIRED WHEATHER OR NOT COMMENT IS MADE | | | BY BLDG REVIEW. | | | | | | 3)NOTE: PLEASE SEE 2002 NEC FOR BRANCH | | | CIRCUITS IN KITCHENS WHICH REQUIRES ALL | | | 15- AND 20-AMPERE, 125-VOLT RECEPTACLES | | | IN NONDWELLING-TYPE KITCHENS TO BE GFCI | | | PROTECTED. THIS REQUIREMENT APPLIES TO | | | EACH AND EVERY 15- AND 20-AMPERE, | | | 125-VOLT KITCHEN RECEPTACLE, WHETHER OR | | | NOT THE RECEPTACLE SERVES COUNTERTOP | | | APPLIANCES. | | | | | | 4)NOTE: PLEASE SEE EM/EXT LIGHTING | | | CIRCUITS ARE NOTED AS BEING WIRED INTO | | | AN EM PANEL?? PLEASE CLARIFY THIS AS IT | | | SEEM EM BACK-UP GEN IS HAS BEEN REMOVED. | | | PLEASE ALSO SEE CIRCUITING SEEMS TO | | | NOTED TO A PANEL "?". PLEASE SEE DUE TO | | | CIRCUITING NOT BEING SHOWN, IT IS | | | UNCLEAR IF PANELS SUBMITTED CONTAIN | | | CIRCUITS? | | | PLEASE CLARIFY FIXTURE TYPE "B" FOR | | | BATTERY BACK UP? | | | IT APPEARS EXT LTS ARE BATTERY BACK-UP. | | | PLEASE CLARIFY IF THESE FIXTURES WILL | | | NOW BECOME BATTERY BACK. PLEASE ALSO SEE | | | LS 101 7-9 FOR CIRCUITING. | | | 700.12E,700.16 ETC. | | | THE BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | PLEASE SEE CONTROL WIRING FOR ATS SHALL | | | ALSO BE REMOVED. PLEASE NOTE THIS ON | | | PLANS. | | | *************************************** | | | PLEASE KNOW A GENERATOR WILL NOT BE | | | PERMITTED ON ROOF, EVEN IF THERE WAS ONE | | | THERE PREVIOUSLY. THIS IS ONLY A NOTE: | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHERREVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | ************************************** | | | PLEASE BE SURE TO REMOVE ANY OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW AND | | | POSSIBLE STAMPING. ONE COPY OF | | | OLD/VOIDED SHEETS SHALL BE SUBMITTED FOR | | | REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-05-22 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-05-22 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2006-05-22 00:00:00 | REVISION DATED 04-20-06 | | | E1.1, E1.2, & E2.0 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-22 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-22 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | ******OK****** | | | | | | IN ACCORDANCE WITH LOCAL REQUIREMENTS, | | | NEW DUCT SMOKE DETECTORS WHERE PROVIDED, | | | SHALL BE WIRED TO CAUSE A GENERAL FIRE | | | ALARM CONDITION IF COMPATABLE WITH | | | EXISTING FIRE ALARM SYSTEM. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-05 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-05 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR CEILINGS AND WALLS. | | | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHER | | | SHALL BE MOUNTED TO SATISFY THE 75' | | | TRAVEL DISTANCE. | | | | | | 3) CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FIR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. | | | | | | | | | MIKE WENNERGREN, CAPTAIN | | | WPBFR(561) 804-4756 | | | PLAN REVIEW(561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-06 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-06 |
Time |
14:16 |
Sent To |
M |
|
| Notes |
| 2006-05-06 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-01 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-01 |
Time |
12:46 |
Sent To |
E |
|
| Notes |
| 2006-05-01 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-29 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-29 |
Time |
15:49 |
Sent To |
M |
|
| Notes |
| 2006-04-29 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-26 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-26 |
Time |
12:43 |
Sent To |
FIRE |
|
| Notes |
| 2006-04-26 00:00:00 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-27 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-27 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2006-02-27 00:00:00 | WAITING FOR "COMM" BD-NEW SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-01 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-01 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2005-12-27 00:00:00 | TO "COMM" BD#32 | | 2005-12-01 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-09 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-09 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2005-09-09 00:00:00 | TO "COMM" BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-08 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-07-07 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-07-15 00:00:00 | IN COMM SPACE #42 | | 2005-07-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-12 |
Time |
16:52 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-05-12 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2006-05-12 00:00:00 | MECH. REV. PAGE M1.1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-12 |
Time |
13:59 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-12 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2006-05-12 00:00:00 | *** MECH. REVISION DENIED *** | | | 1) MECHANICAL REVISION HAS CHANGES MADE | | | IN PEN ON A PHOTO-COPIED PLAN WITH AN | | | ENGINEER'S SEAL ON THEM, CHANGES MAY NOT | | | BE DONE IN PEN AS THE PLANS MAY BE | | | ALTERED AT ANY TIME. | | | | | | 2) THE ENGINEER DID NOT PUT THE DATE ON | | | HIS SEAL, PER FAC 61G15-23.002 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-08 |
Time |
10:27 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-08 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | REVISION TO MECH. PLANS PAGE M 1.1 . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-05-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-02 |
Time |
11:15 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-02 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2006-05-02 00:00:00 | REVISION TO MECH. PLANS PAGE M1.0 & | | | M1.1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-23 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-23 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-10-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-10-15 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-10-15 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2005-10-15 00:00:00 | PLAN DENIED | | | IN REGARDS TO MECHANICAL NOTES | | | #11.PLEASE REFER TO SECTION 602.2.1 | | | MATERIALS EXPOSED WITHIN PLENUMS.2001 | | | FBD(M).IF YOU HAVE COMBUSTIBLE MATERIALS | | | IN THE PLENUM PLEASE REFER TO SECTION | | | 103.7 ALTERNATE MATERIALS AND | | | METHODS.2001 FBC(M). | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-27 |
Time |
09:42 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-07-27 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2005-07-27 00:00:00 | DENIED: | | | 1.PLANS ARE TO BE SIGNED, SEALED AND | | | DATED BY THE ENGINEER PER FS 471.025. | | | | | | 2.PLAN SHEET M0.1 MECHANICAL NOTE #10 | | | STATES "CONDENSATE SHALL BE SCHEDULE 40 | | | PVC OR COPPER IF LOCATED IN A RETURN AIR | | | PLENUM".PLAN SHEET M 1.1, INDICATES | | | RETURN AIR PLENUM THEREFORE PVC WILL NOT | | | BE ALLOWED. | | | | | | 3.PLEASE INDICATE IF THE OUTSIDE AIR | | | WILL BE REQUIRED TO BE CHANGED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-03-09 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-03-09 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2006-03-09 00:00:00 | PASSED/PROVISO | | | | | | SINK TRAP SHALL NOT EXCEED 8' FROM | | | EXISING VENT. - NO DEAD ENDS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-01-21 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-01-21 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-01-21 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2006-01-21 00:00:00 | PAUL SCHMITZ | | | FBC 2001 PLUMBING CODE PLAN REVIEW | | | FBC 2001 CH 11, FL ACESSIBILITY CODE | | | DENIED 3RD TIME | | | | | | 1)SHT A-1 DEMOLITION PLAN NOTES. | | | ?P704.5 DEAD ENDS. IN THE INSTALLATION | | | OR REMOVAL OF ANY PART OF A | | | DRAINAGE SYSTEM, DEAD ENDS SHALL BE | | | PROHIBITED. | | | 2. SHT A-1A SHOWS A KITCHEN SINK. | | | THE SINK SHALL BE ACCESSIBLE. | | | PLEASE SUBMIT A DETAIL, SHOWING | | | COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS, TO THIS COMMENT. | | | FORWARD APPROACH REQUIRED WITH NO | | | CABINET DOORS ALLOWDED. | | | ?11-4.24.1 GENERAL. SINKS REQUIRED TO | | | BE ACCESSIBLE BY ?11-4.1 SHALL | | | COMPLY WITH ?11-4.24. | | | ?11-4.24.2 HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER OR RIM NO | | | HIGHER THAN 34 IN. (865 MM) ABOVE THE | | | FINISH FLOOR. | | | ?11-4.24.3 KNEE CLEARANCE. KNEE | | | CLEARANCE THAT IS AT LEAST 27 IN. (685 | | | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 | | | IN (485 MM) DEEP SHALL BEPROVIDED | | | UNDERNEATH SINKS. | | | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A | | | MAXIMUM OF 6-1/2 IN (165 MM)DEEP. | | | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE AT LEAST 30 IN. BY 48 | | | IN. (760 MM BY 1220 MM) COMPLYING WITH | | | 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH.THE CLEAR FLOOR SPACE SHALL | | | BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 IN. (485 MM) | | | UNDERNEATH THE SINK (SEE FIGURE | | | 11-32). | | | ?11-4.24.6 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES EXPOSED | | | UNDER SINKS SHALL BE INSULATED OR | | | OTHERWISE CONFIGURED SO AS TO PROTECT | | | AGAINST CONTACT.THERE SHALL BE NO | | | SHARP OR ABRASIVE SURFACES UNDER | | | SINKS.( NO GARBAGE DISPOSAL) | | | ?11-4.24.7 FAUCETS. FAUCETS SHALL | | | COMPLY WITH ?11-4.27.4.LEVER- | | | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR | | | ELECTRONICALLY CONTROLLED MECHANISMS | | | ARE ACCEPTABLE DESIGNS. | | | 11-4.22.2 DOORS SHALL NOT SWING INTO THE | | | CLEAR FLOOR SPACE REQUIRED FOR A FIXTURE | | | 3. SUBMIT A SANT. AND A WATER RISER | | | DIAGRAM IN ISOMETRIC FORM. SHOW ALL PIPE | | | SIZES, TRAP, VENT/SANT CONNECTIONS FOR | | | THE SANT. AND SHOW ALL PIPE SIZES, | | | VALVES, WATER HAMMER ARRESTORS, (IF | | | REQUIRED BY SECTION 604.9), AND POINT OF | | | CONNECTION. SECTION 104.3.1.1. - NO | | | RESPONSE TO COMMENT. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-11-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-11-12 |
Time |
12:25 |
Rev Time |
0.45 |
| Received By |
kstevens |
Date |
2005-11-12 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2005-11-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | 1. BOTH SETS OF MECHINCAL AND ELECTRICAL | | | SHEETS SHALL BE SIGNED, SEALED, AND | | | DATED PER FAC 61G15-23.002(1) & FS | | | 471.2055. - STILL SHEET NOT SIGNED, | | | SEALED, DATED | | | 2. SHT A-1 SHOWS A KITCHEN SINK, AND | | | SINCE THERE IS NO DEMO SHEET, EXISTING | | | FLOOR PLAN, OR NOT INDICATED AS AN | | | EXISTING SINK, THE SINK SHALL BE | | | ACCESSIBLE. PLEASE SUBMIT A DETAIL | | | SHOWING COMPLIANCE WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. - NO RESPONSE NOTED | | | TO THIS COMMENT. - FORWARD APPROACH | | | REQUIRED WITH NO CABINET DOORS ALLOWDED. | | | ALSO DOOR CAN NOT SWING INTO CLEAR FLOOR | | | SPACE OF ANY FIXTURE. | | | 3. SUBMIT A SANT. AND A WATER RISER | | | DIAGRAM IN ISOMETRIC FORM. SHOW ALL PIPE | | | SIZES, TRAP, VENT/SANT CONNECTIONS FOR | | | THE SANT. AND SHOW ALL PIPE SIZES, | | | VALVES, WATER HAMMER ARRESTORS, (IF | | | REQUIRED BY SECTION 604.9), AND POINT OF | | | CONNECTION. SECTION 104.3.1.1. - NO | | | RESPONSE TO COMMENT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-08 |
Time |
08:25 |
Rev Time |
0.62 |
| Received By |
kstevens |
Date |
2005-08-06 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2005-08-08 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL ARCHITECTURAL SHEETS: PER FAC | | | 61G1-16.004(2) & FS 481.219 THE FIRM | | | LICENSE NUMBER, (CERTIFICATE OF | | | AUTHORIZATION), IS REQUIRED IN THE TITLE | | | BLOCK OF EACH SHEET. | | | 2. BOTH SETS OF MECHINCAL AND ELECTRICAL | | | SHEETS SHALL BE SIGNED, SEALED, AND | | | DATED PER FAC 61G15-23.002(1) & FS | | | 471.2055. | | | 3. SHT A-1 SHOWS A KITCHEN SINK, AND | | | SINCE THERE IS NO DEMO SHEET, EXISTING | | | FLOOR PLAN, OR NOT INDICATED AS AN | | | EXISTING SINK, THE SINK SHALL BE | | | ACCESSIBLE. PLEASE SUBMIT A DETAIL | | | SHOWING COMPLIANCE WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. | | | 4. SUBMIT A SANT. AND A WATER RISER | | | DIAGRAM IN ISOMETRIC FORM. SHOW ALL PIPE | | | SIZES, TRAP, VENT/SANT CONNECTIONS FOR | | | THE SANT. AND SHOW ALL PIPE SIZES, | | | VALVES, WATER HAMMER ARRESTORS, (IF | | | REQUIRED BY SECTION 604.9), AND POINT OF | | | CONNECTION. SECTION 104.3.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|