| 2005-07-22 00:00:00 | DENIED |
| | |
| | 1) THE WRONG PRESSURES ARE CIRCLED ON |
| | THE COMPONENT AND CLADDING SHEETS. THE |
| | FIRST TABLE SHOULD BE USED. THE |
| | EFFECTIVE WIND AREA SHALL NOT BE GREATER |
| | THAN THE AREA THAT IS TRIBUTARY TO AN |
| | INDIVIDUAL FASTENER. SEE ASCE 7-98. |
| | |
| | 2) PRODUCT APPROVALS SUBMITTED |
| | WITH PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE |
| | AT WWW.FLORIDABUILDING.ORG. PRODUCTS |
| | WITH STATEWIDE APPROVAL ARE REQUIRED TO |
| | BE SUBMITTED WITH A COVER SHEET THAT |
| | LISTS THE PRODUCT IDENTITY NUMBER (FL#) |
| | FROM THE STATE. IF THE PRODUCT DOES NOT |
| | HAVE STATEWIDE APPROVAL, SUBMIT AN |
| | APPLICA- TION FOR LOCAL PRODUCT APPROVAL |
| | OR SITE SPECIFIC FORM PER RULE 9B-72. |
| | |
| | 3) THERE IS A PRODUCT CODE GT THAT IS |
| | NOT LISTED IN THE SHUTTER PRODUCT KEY. |
| | |
| | 4) MULTIPLE FASTENERS, SPACINGS AND |
| | SEPARATIONS FROM GLASS ARE CIRCLED ON |
| | THE DRAWINGS. SUBMIT AN INSTALLATION |
| | SCHEDULE WITH THE REQUIRED INFORMATION |
| | AND IN THE FORM OF THE SAMPLE THAT IS |
| | ATTACHED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |