| Plan Review Stops For Permit 05070203 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-08-10 |
Time |
11:44 |
Rev Time |
1.50 |
| Received By |
mjacobs |
Date |
2005-08-10 |
Time |
11:27 |
Sent To |
PC |
|
| Notes |
| 2005-08-10 00:00:00 | ****CORRECTIONS**** | | | | | | MYRON JACOBS, BUILDING PLANS EXAMINER | | | 561-805-6726 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC*CITY OF WESTPALM BEACH | | | AMENDMENTS. TO THE FBC2001 | | | | | | BLDG: PROVISO. | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED. | | | | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-15 |
Time |
11:33 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-09-15 |
Time |
11:05 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-29 |
Time |
12:11 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-29 |
Time |
11:16 |
Sent To |
M |
|
| Notes |
| 2005-07-29 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE VERIFY THE TRANSFER SWITCH | | | RATING OF 600 AMPS FOR A 136 AMP LOAD. | | | | | | 2} THE TRANSFER SWITCH MUST BE SERVICE | | | RATED PER 225.36. PLEASE INDICATE SAME. | | | | | | 3} THE RISER DOES NOT SHOW HOW THE | | | CIRCUITS WILL BE LIMITED TO THE | | | CALCULATIONS INDICATED.THE ATS APPEARS | | | TO FEED ALL 4 HOUSE PANELS. | | | | | | 4} A DEMAND FACTOR MAY BE TAKEN ON THE | | | LIGHTING CIRCUITS ONLY. THE REST OF THE | | | INTENDED LOAD MUST BE AT 100%. SEE | | | 702.5. | | | | | | 5} THE DESIGNER OF RECORD MUST SIGN AND | | | SEAL THE PLAN. SEE 61G15-23.002 FAC.,471 | | | .025 FS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-12 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-12 |
Time |
14:15 |
Sent To |
E |
|
| Notes |
| 2005-09-12 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-18 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-18 |
Time |
09:32 |
Sent To |
E |
|
| Notes |
| 2005-07-18 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-07 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2005-07-07 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-01 |
Time |
09:56 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-08-01 |
Time |
09:56 |
Sent To |
P |
|
| Notes |
| 2005-08-01 00:00:00 | MECH. PLAN REVIEW: | | | | | | MECH. PROVISO: | | | | | | IF ELECT. GENERATOR IS 10 FEET FROM | | | BUILDING AND EXHAUST IS DIRICTED AWAY | | | FROM BUILDING, THIS MEET INTENT OF MECH. | | | CODE. | | | 2001 FBC/M 804.3.3 TERMINATION. | | | | | | 2001 FBC/M SECTION 915 | | | REQUIREMENT OF NFPA 37 8.2.3.2 | | | EXHAUST SYSTEM TERMINATION. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-01 |
Time |
15:15 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-01 |
Time |
15:15 |
Sent To |
B |
|
| Notes |
| 2005-08-01 00:00:00 | GAS PERMIT REQUIRED BEFORE FINAL RES-GEN | | | INSPECTION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-15 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-15 |
Time |
13:55 |
Sent To |
I |
|
| Notes |
|
|