Plan Review Details - Permit 05070142
| Plan Review Stops For Permit 05070142 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-21 |
Time |
14:29 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-09-21 |
Time |
14:29 |
Sent To |
PC |
|
| Notes |
| 2005-09-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05070142 | | | ADD: 8004 CRANES POINTE WAY | | | CONT: SOUTHERN POOLS INC | | | TEL: (954)444-7023 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | POOL REVIEW | | | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST | | | STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-05 |
Time |
07:25 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-05 |
Time |
07:24 |
Sent To |
PC |
|
| Notes |
| 2005-08-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05070142 | | | ADD: 8004 CRAINES POINTE WAY | | | CONT: SOUTHERN POOLS | | | TEL: (954)444-7023 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) POOL HEATER DETAIL BY SINCLAIR | | | ENGINEERING, 2 ENGINEERS CAN NOT BE ON | | | SAME PROJECT, POOL PLANS SEALED BY JOHN | | | BROWN. | | | | | | 2) PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-18 |
Time |
09:04 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-07-18 |
Time |
08:59 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-09-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-02 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-02 |
Time |
09:02 |
Sent To |
P |
|
| Notes |
| 2005-09-02 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-15 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-15 |
Time |
11:12 |
Sent To |
E |
|
| Notes |
| 2005-07-15 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
14:49 |
Sent To |
I |
|
| Notes |
| 2005-07-06 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-20 |
Time |
14:38 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-09-20 |
Time |
14:38 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-25 |
Time |
14:21 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-07-25 |
Time |
14:04 |
Sent To |
B |
|
| Notes |
| 2005-07-25 00:00:00 | DENIED; | | | 1.PUMPS AND EQUIPMENT SHALL BE MOUNTED | | | ON A SUBSTANTIAL BASE. SLAB SHALL BE A | | | NOMINAL 4" THICK. SEC 424.2.7.2. | | | (DETAIL) | | | 2.VALVES SHALL BE MADE OF MATERIALS THAT | | | ARE APPROVED IN FBC PLUMBING. THEY WILL | | | BE READILY ACCESSIBLE FOR MAINT.AND | | | REMOVAL. SEC. 424.2.8.2 ALSO 424.2.8.3 | | | AND 424.2.8.4 ADD TO NOTES.PURPLE PRIMER | | | REQUIRED ON PVC PIPING SEC 605.21. (ADD | | | TO NOTES) | | | 3.ALL WATER HEATER EQUIPMENT SHALL BE | | | INSTALLED WITH FLANGES OR UNION | | | CONNECTIONS ADJACENT TO HEATER. | | | 424.2.14.4. (ADD TO NOTES) | | | 4.GAS PIPING SHALL COMPLY WITH FBC 2001 | | | FUEL GAS. SEPARATE PLANS AND PERMIT | | | REQUIRED. SEC.424.2.15. (ADD TO NOTES. | | | PLUMBING PLAN REVIW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-14 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-14 |
Time |
16:03 |
Sent To |
B |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |