Plan Review Details - Permit 05070083
Plan Review Stops For Permit 05070083
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-10-04 Cont ID  
Sent By jwitmer Date 2005-10-04 Time 11:05 Rev Time 1.55
Received By jwitmer Date 2005-10-04 Time 11:04 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-31 Cont ID  
Sent By jwitmer Date 2005-07-31 Time 07:35 Rev Time 0.55
Received By jwitmer Date 2005-07-31 Time 07:33 Sent To PC
Notes
2005-07-31 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05070083
 ADD: 6118 WILDCAT RUN
 CONT:O/B FAKHARI, MOHAMMAD
 TEL: (561)310-7460
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 THE PERMIT APPLICATION DOESN'T INDICATE
 WHAT MATERIALS THE EXISTING FIREPLACE
 NOR CHIMNEY IS MADE OF. IF THE FIREPLACE
 AND OR CHIMNEY IS FACTORY BUILT, IT HAS
 TO CONFORM TO THOUGHS SPECIFICATIONS
 UNDER WHICH IT WAS BUILT AND TESTED.
  
 2806.1.1 FACTORY-BUILT FIREPLACES SHALL
 BE LISTED AND SHALL BE INSTALLED
 IN ACCORDANCE WITH THE CONDITIONS OF
 THE LISTING.
  
 2806.1.2 FACTORY-BUILT FIREPLACES
 SHALL BE TESTED IN ACCORDANCE WITH
 AND MEET THE REQUIREMENTS OF UL 127.
  
 2804.4.1 FACTORY-BUILT CHIMNEYS SHALL BE
 LISTED AND SHALL BE INSTALLED
 IN ACCORDANCE WITH THE CONDITIONS OF
 THE LISTING, AND THE MANUFACTURER'S
 INSTRUCTIONS.NOTHING CONTAINED IN
 THIS CODE SHALL BE CONSTRUED AS
 PROHIBITING THE USE OF INSULATED
 SUSPENDED FACTORY-BUILT CHIMNEYS
 PROVIDED SUCH ASSEMBLIES HAVE BEEN
 TESTED AND APPROVED BY A RECOGNIZED
 LABORATORY FOR THE USE INTENDED AND
 ARE INSTALLED IN ACCORDANCE WITH
 THEIR APPROVAL.
  
  
 ALTERING THE END CAPS AND THE DISPERSION
 OF SMOKE AND HEAT WITH THE DRAWINGS
 BY P.E. GORDON BUCK IS NOT RECOGNIZED
 NOR TESTED BY UL 127.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2005-07-31 Cont ID  
Sent By jwitmer Date 2005-07-31 Time 07:36 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-27 Cont ID  
Sent By adarroug Date 2005-09-27 Time 09:53 Rev Time 0.00
Received By adarroug Date 2005-09-27 Time 09:53 Sent To B
Notes
2005-09-27 00:00:00TO "JWITMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-31 Cont ID  
Sent By jwitmer Date 2005-07-31 Time 07:37 Rev Time 0.00
Received By jwitmer Date 2005-07-06 Time 09:15 Sent To  
Notes
2005-07-06 00:00:00TO "MISC" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-07-31 Cont ID  
Sent By jwitmer Date 2005-07-31 Time 07:36 Rev Time 0.00
Received By jwitmer Date 2005-10-04 Time 11:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-07-31 Cont ID  
Sent By jwitmer Date 2005-07-31 Time 07:36 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***