| Plan Review Stops For Permit 05070030 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-23 |
Time |
07:48 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2005-08-22 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-01 |
Time |
06:57 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2005-08-01 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2005-08-01 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2. SINCE BBQ OPTION WILL NOT BE USED. | | | REMOVE ALL REFERENCE ON PLANS REGARDING | | | BBQ. | | | | | | 3.SIGN OWNER/AGENT ON ENERGY CALCS. | | | | | | 4.BASED ON SBCCI BUILDING VALUATION | | | DATA THE PERMIT VALUATION HAS BEEN | | | CHANGED TO $284,256.ADDITIONAL PERMIT | | | FEES ARE DUE. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-10 |
Time |
06:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-10 |
Time |
06:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-09 |
Time |
20:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-09 |
Time |
20:26 |
Sent To |
PC |
|
| Notes |
| 2006-02-09 00:00:00 | *** PLANS REDLINED** | | | | | | RISER IS A 400A SERVICE, MIN GEC SHALL | | | BE SIZED PER 250.66, 1/0 MIN. | | | | | | REQUIRES A MIN OF 2 GRND RODS/ FOOTER | | | STEEL. | | | 250.50,250.56. | | | FOOTER STEEL WAS REMOVED FROM RISER, | | | HOWEVER THIS IS REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-14 |
Time |
20:46 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-07-14 |
Time |
20:33 |
Sent To |
M |
|
| Notes |
| 2005-07-14 00:00:00 | ELEC FOR REVIEW. | | | REDLINED THE FOLLOWING. | | | | | | PLEASE SEE MISSING EQUIPMENT GROUNDING | | | CONDUCTOR FROM MAIN TO POOL SUB PANEL. | | | 250.110,250.122 ETC | | | | | | POOL PUMP, 125% FOR CONTINUOUS LOAD.(3 | | | OR MORE HOURS). | | | | | | THERE IS NO NEED FOR CORRECTIONS, | | | HOWEVER OF PLANS ARE REVISED FOR JOBSITE | | | CHANGES, PLEASE MAKE THE ABOVE | | | CORRECTIONS/ADJUSTMENTS AT THAT TIME. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
15:42 |
Sent To |
E |
|
| Notes |
| 2006-03-09 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-07 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-07 |
Time |
15:21 |
Sent To |
E |
|
| Notes |
| 2006-02-07 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
16:31 |
Sent To |
B |
|
| Notes |
| 2005-08-18 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-14 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-14 |
Time |
10:39 |
Sent To |
E |
|
| Notes |
| 2005-07-14 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-01 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-07-01 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-07-20 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-07-20 |
Time |
16:24 |
Sent To |
P |
|
| Notes |
| 2005-07-20 00:00:00 | NO PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-23 |
Time |
10:29 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-07-23 |
Time |
10:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-13 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-13 |
Time |
17:12 |
Sent To |
I |
|
| Notes |
|
|