| Plan Review Stops For Permit 05070015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-17 |
Time |
18:48 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-17 |
Time |
18:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-03 |
Time |
12:25 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-03 |
Time |
12:25 |
Sent To |
PC |
|
| Notes |
| 2005-08-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05070015 | | | ADD: 200 GREGORY RD | | | CONT: CARPENTER ELEC | | | TEL: (561)848-7881 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE INFORMATION ON SLAB AND | | | ANCHORING OF UNIT. | | | 1606.1.3 ANCHORAGE AGAINST OVERTURNING, | | | UPLIFT AND SLIDING. STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS | | | AND CLADDING IN A BUILDING OR | | | STRUCTURE SHALL BE ANCHORED TO RESIST | | | WIND-INDUCED OVERTURNING, UPLIFT | | | AND SLIDING AND TO PROVIDE CONTINUOUS | | | LOAD PATHS FOR THESE FORCES TO THE | | | FOUNDATION.WHERE A PORTION OF THE | | | RESISTANCE TO THESE FORCES IS PROVIDED | | | BY DEAD LOAD, THE MINIMUM DEAD LOAD | | | LIKELY TO BE IN PLACE DURING A DESIGN | | | WIND EVENT SHALL BE USED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-01 |
Time |
07:02 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-03 |
Time |
12:10 |
Sent To |
PC |
|
| Notes |
| 2005-07-28 00:00:00 | MECH. PLAN REVIEW: | | | | | | ELECT. GENERATOR MUST BE 10 FEET FROM | | | BUILDING AND GENERATOR EXHAUST DIRECTED | | | AWAY FROM BUILDING. | | | | | | 2001 FBC/M 804.3.3 TERMINATION. | | | | | | 2001 FBC/M SECTION 915 NFPA 37 | | | 8.2.3.2 EXHAUST SYSTEM TERMINATION. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-16 |
Time |
07:10 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-08-16 |
Time |
07:10 |
Sent To |
M |
|
| Notes |
| 2005-08-16 00:00:00 | ***** NOTES***** | | | | | | 1)NOTE: PLEASE SEE THE ONLY PERMITTED | | | DE-RATING FOR GENERATOR LOADS ARE THE | | | GENERAL LIGHTING AND RECEPT LOADS. | | | | | | ALL OTHER LOADS, APPLIANCES, ETC MUST BE | | | 100%. | | | | | | ALL CONNECTED LOADS ASINDICATED ON | | | PANEL, DO NOT EXCEED RATING OF GEN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-26 |
Time |
16:28 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-07-26 |
Time |
15:40 |
Sent To |
M |
|
| Notes |
| 2005-07-26 00:00:00 | ************ UNSAT ************* | | | | | | 1)NOTE: PLEASE SUBMIT SPECS /CUT SHEETS | | | FOR ATS. | | | | | | 2)NOTE: PLEASE INDICATE EQUIPMENT ON THE | | | LOAD SIDE OF ATS. PLEASE INDICATE | | | WHEATHER OR NOT A MAIN OR MAIN CIR BRKR | | | PANEL? | | | 225.31, 110.27 | | | | | | 3)NOTE: PLEASE KNOW, ONLY GEN LT/AND | | | RECEPT LOADS MAY TAKE DERATINGS AS | | | PERMITTED UNDER NEC. 220.31 | | | ALL CONNECTED APPLIANCE LOADS, MOTOR | | | LOADS,ETC SHALL BE FIGURED AT 100%. | | | PLEASE SEE ANY CONTINUOUS LOADS SHALL BE | | | 125%. | | | PLEASE SEE THAT A/C LOAD MUST BE FIGURED | | | FOR HEAT STRIP LOAD, UNLESS MEANS OF | | | AUTOMATIC LOAD SHEDDING IS PROVIDED. | | | LOAD SHEDDING MAY ALSO BE PROVIDED FOR | | | OTHER CONNECTED LOADS. | | | GENERATOR MUST BE SIZED FOR ALL LOADS IF | | | ATS IS PROVIDED. | | | 702.5 | | | | | | 4)NOTE: PLEASE SEE FBC 104.2.1 WHICH | | | REQUIRES THE PRINTED NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR | | | PLANS/DESIGN. | | | | | | 5)NOTE: PLEASE SEE MANUFACTURE CUT SHEET | | | FOR GENERATOR. PLEASE CLEARLY INDICATE | | | ON BOTH SETS WHICH UNIT IS TO BE | | | INSTALLED. | | | | | | 6)NOTE: PLEASE SUBMIT A DETAIL FOR SLAB | | | AND ATTACHMENT FOR UNIT. | | | | | | 7)NOTE: PLEASE BE SURE THE SURVEY SHOWS | | | THE MIN BASED FLOOD ELEVATION(BFE). | | | PLEASE SEE THAT SLAB IS 6" ABOVE BFE. | | | | | | PLEASE SEE MECHANICAL REVIEW COMMENTS | | | AND/OR NOTES PERTAINGING TO MIN | | | CLEARNECE FROM OPEINS INTO DWELLING | | | UNIT. | | | | | | PLEAS KNOW, A 4X MAY BE ACCESSED IF | | | GENERATOR IS INSTALLED, WIRED ETC BEFORE | | | ELECTRICLA PERMIT IS ISSUED AND POSTED | | | ON THE JOBSITE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-15 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-15 |
Time |
16:51 |
Sent To |
E |
|
| Notes |
| 2005-08-15 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-14 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-14 |
Time |
10:00 |
Sent To |
E |
|
| Notes |
| 2005-07-14 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-07-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-08-16 |
Time |
10:59 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-08-16 |
Time |
10:59 |
Sent To |
B |
|
| Notes |
| 2005-08-16 00:00:00 | PREVIOUS QUESTIONS HAVE BEEN ADRESSED IN | | | ELECT. REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-07-27 |
Time |
10:58 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-07-27 |
Time |
10:57 |
Sent To |
P |
|
| Notes |
| 2005-07-27 00:00:00 | MECH. PLAN REVIEW: | | | | | | IF ELECT. GENERATOR IS 10 FEET FROM | | | BUILDING AND EXHAUST IS DIRECTED AWAY | | | FROM BUILDING THIS MEET INTENT OF MECH. | | | CODE. | | | 2001 FBC/M 804.3.3 TERMINATION. | | | | | | 2001 FBC/M SECTION 915 | | | REQUIREMENT OF NFPA 37 | | | 8.2.3.2 EXHAUST SYSTEM | | | TERMINATION. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-01 |
Time |
07:00 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-01 |
Time |
07:00 |
Sent To |
B |
|
| Notes |
| 2005-08-01 00:00:00 | GAS APPLICATION 05070847 IS ON FILE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-13 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-13 |
Time |
16:51 |
Sent To |
I |
|
| Notes |
|
|