| Plan Review Stops For Permit 05061880 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-05-30 |
Time |
12:47 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-05-30 |
Time |
12:47 |
Sent To |
PC |
|
| Notes |
| 2006-05-30 00:00:00 | NEW PRODUCT APPROVALS: | | | FL 3230 BESAM AUTO EXTERIOR DOOR | | | ARCH 03-121108 STOREFRONT | | | ARCH 01-0329.02 FIXED STOREFRONT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-24 |
Time |
16:16 |
Rev Time |
1.66 |
| Received By |
jwitmer |
Date |
2006-02-24 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
| 2006-02-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05061880 | | | ADD: 5400 S DIXIE HWY | | | CONT: CONSILIUM ATLANTIC | | | TEL: (954816-3351 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION | | | ACTION: DENIED | | | | | | | | | ****NOTE*** | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 1) ARCH THE MIAMI-DADE NOA SUBMITTED | | | UNDER ARCH / STOREFRONTS DOES NOT HAVE | | | FLORIDA APPROVAL/ LOCALPRODUCT APPROVAL | | | WOULD BE REQUIRED. | | | | | | 2) ARCH SHOP DRAWINGS INDICATE THE | | | DESIGN TO BE UNDER THE 2004 FBC, CORRECT | | | TO 2001 FBC. | | | | | | 3) SHOP DRAWINGS INDICATE USE OF | | | STRUCTURAL MULLIONS BUT NO APPROVAL: | | | 1707.4.5.1 MULLIONS OCCURRING BETWEEN | | | INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | | | | 4)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | | | | 5) SHOP DRAWINGS INDICATE MULLIONS BY | | | BESAM, THERE IS NO PRODUCT APPROVALS | | | UNDER THIS NAME FOR MULLIONS. | | | SEE RULE 9B72(29)(B) REQUIRING PRODUCT | | | APPROVALS FOR MULLIONS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-01-25 |
Time |
15:54 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2006-01-25 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2006-01-25 00:00:00 | REVISION # 2 11-01-05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-10-03 |
Time |
09:19 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2005-10-03 |
Time |
08:24 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-07 |
Time |
14:03 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-08-07 |
Time |
14:01 |
Sent To |
PC |
|
| Notes |
| 2005-08-07 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05061880 | | | ADD: 5400 S DIXIE HWY | | | CONT: CONSILIUM ATLANTIC | | | TEL: (954)788-3884 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3) PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | THERE ARE PAGES MISSING THE RAISED SEAL, | | | AND PAGES MISSING BOTH THE SEAL & | | | SIGNATURE. | | | | | | 4) ACCESSIBLE DRESSING ROOM ISMISSING | | | BENCH:11-4.35.4 BENCH. EVERY ACCESSIBLE | | | DRESSING ROOM SHALL HAVE A 24 IN. BY | | | 48 IN.(610 MM BY 1220 MM) BENCH FIXED | | | TO THE WALL ALONG THE LONGER | | | DIMENSION.THE BENCH SHALL BE MOUNTED | | | 17 IN. TO 19 IN.(430 MM TO 485 MM) | | | ABOVE THE FINISH FLOOR.CLEAR FLOOR | | | SPACE SHALL BE PROVIDED ALONGSIDE THE | | | BENCH TO ALLOW A PERSON USING A | | | WHEELCHAIR TO MAKE A PARALLEL TRANSFER | | | ONTO THE BENCH.THE STRUCTURAL STRENGTH | | | OF THE BENCH AND ATTACHMENTS SHALL | | | COMPLY WITH ?11-4.26.3.WHERE INSTALLED | | | IN CONJUNCTION WITH SHOWERS, SWIMMING | | | POOLS, OR OTHER WET LOCATIONS, WATER | | | SHALL NOT ACCUMULATE UPON THE SURFACE OF | | | THE BENCH AND THE BENCH SHALL HAVE A | | | SLIP-RESISTANT SURFACE. | | | | | | 5) PLANS INDICATE THE USE OF POWER | | | ACTIVATED AUTOMATIC SLIDING GLASS DOORS, | | | PROVIDE COMPLIANCE WITH : | | | 1012.4 HORIZONTAL SLIDING DOORS. | | | APPROVED AND LISTED HORIZONTAL SLIDING | | | DOORS COMPLYING WITH THE FOLLOWING | | | CONDITIONS MAY BE USED IN A MEANS OF | | | EGRESS WHEN SPECIFICALLY PERMITTED BY | | | 1012.1.2, EXCEPTION 3. | | | FOR A BIPARTING SLIDING DOOR IN THE | | | EMERGENCY BREAK-OUT MODE, A DOOR LEAF | | | LOCATED WITHIN A MULTIPLE-LEAF OPENING | | | SHALL BE EXEMPT FROM THE MINIMUM 32 IN. | | | (81-CM) SINGLE-LEAF REQUIREMENT OF IF A | | | MINIMUM OF 32 IN.(81 CM) CLEAR OPENING | | | IS PROVIDED BY ALL LEAFS BROKEN OUT. | | | | | | 6) RESTROOMS: 1204.2 SURROUNDING | | | MATERIALS. THE WALLS AND FLOORS OF ALL | | | PUBLIC REST ROOMS SHALL BE LINED WITH | | | NONABSORBENT MATERIAL TO A HEIGHT OF 4 | | | FT (1219 MM) ABOVE THE FLOOR. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-09 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-09 |
Time |
18:24 |
Sent To |
PC |
|
| Notes |
| 2006-02-09 00:00:00 | REDLINED PLANS : | | | | | | PLEASE SEE MDP IS SHOWN AS MLO, AND A | | | MAIN CIRCUIT BREAKER WILL BE REQUIRED | | | FOR THE MDP AS THIS SHOWS MORE THAN 6 | | | MAINS AND SPACES. | | | 230.70,230.71 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-20 |
Time |
20:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-20 |
Time |
20:22 |
Sent To |
|
|
| Notes |
| 2005-12-20 00:00:00 | ****** UNSAT ***** | | | | | | PLEASE SEE MINOR CHANGES NOTED ON | | | REVISION COVER SHEET, HOWEVER THERE AHVE | | | BEEN SOME MAJOR CHNAGES NOT ON ORIGINAL | | | PLANS. | | | | | | | | | 1)NOTE: PLEASE SEE MANY WINDOWS ADDED | | | NOT ON PREVIOUS ELECTRICAL PLANS. | | | PLEASE SEE 210.62, 220.12A FOR MIN "SHOW | | | WINDOWS" NOW REQUIRED ABOVE ALL WINDOWS. | | | PLEASE ALSO ADJUST ALL CIRCUITING FOR | | | THESE AS THEY ARE REQUIRED TO BE ON | | | SEPARATE CIRCUITS. | | | | | | 2)NOTE: PLEASE SEE A PANEL "E" IS SHOWN | | | ON ON MDP , HOWEVER NO PANEL "E" | | | SCHEDULE WAS SUBMITTED. IS THIS "EM" ON | | | PLANS? | | | PLEASE CORRELATE. | | | | | | 3)NOTE: PLEASE SEE MDP IS NOW SHOWN AS | | | MLO ON SCHEDULE AND MCB ON RISER. PLEASE | | | SEE 230.70,230.71 ETC, A MAIN CIRCUIT | | | BREAKER WILL BE REQUIRED. | | | PLEASE MAKE NESS CHANGES. | | | PLEASE ALSO SEE MDP SEEMS TO INDICATE A | | | "SPARE" 800A 3-P IN SPACE #7?? PLEASE | | | VERIFY. | | | | | | 4)NOTE: PLEASE KNOW, DUE TO THE SCOPE OF | | | WORK BEING DONE AND THE REQUIREMENTS OF | | | CHAPTER 34 OF THE FBC, ALL EXISTING AND | | | NEW ELECTRICAL SHALL MEET CURRENT 2002 | | | NEC. | | | PLEASE SEE ALL OCP SHOWN AS EXISITNG FOR | | | EQUIPMENT, A/C 'S ETC. THESE SHOULD BE | | | VERIFIED IN FEILD AND ADJUSTED IF OCP | | | DOES NOT MEET MIN OR IS SIZED TOO HIGH | | | FOR UNIT. | | | | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWERS WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-30 |
Time |
16:48 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-09-27 |
Time |
21:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-07 |
Time |
12:26 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-07-07 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2005-07-07 00:00:00 | ********** UNSAT ****** | | | | | | 1)NOTE: PLEASE SEE MISSING TITLE | | | BLOCK/TITLE BLOCK INFORMATION AS | | | REQUIRED UNDER FAC 61G1-16.004, | | | 61G15-23.002, FS 471.025 | | | PLEASE ALSO SEE SOME ARCH SHEETS ARE NOT | | | SEALED BY ARCH. FS 481.221 | | | | | | | | | 2)NOTE: PLEASE CORRLETATE PLANS WITH | | | SCOPE OF WORK ON APPLICATION ETC. | | | PLEASE SEE PLANS CALL FOR GENERATOR | | | ROOM? IS THERE GOING TO BE A GEN | | | INSTALLED IN THIS SCOPE OF WORK? IF SO, | | | PLEASE INCLUDE ALL INFORMATION AS | | | REQUIRED. | | | | | | 3)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | WITH PANEL SCHEDULES SUBMITTED. | | | PANEL A/C-2? | | | 215.5 | | | | | | 4)NOTE: PLEASE SEE OCP FOR CU'S, PLEASE | | | VERIFY SIZING. SEEMS EXCEED 150% OF FLA. | | | ? | | | 215.5 | | | | | | 5)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | AND PLEASE SHOW ALL CONTINUOUS LOADS AT | | | 125%. 220.10,220.11,220.13 , | | | 215.3,230.42 ETC. | | | | | | 6)NOTE: PLEASE SEE 2002 NEC 210.8B3 | | | WHICH REQUIRES ALL 15- AND 20-AMPERE, | | | 125-VOLT RECEPTACLES IN NONDWELLING-TYPE | | | KITCHENS TO BE GFCI PROTECTED. THIS | | | REQUIREMENT APPLIES TO EACH AND EVERY | | | 15- AND 20-AMPERE, 125-VOLT KITCHEN | | | RECEPTACLE, WHETHER OR NOT THE | | | RECEPTACLE SERVES COUNTERTOP APPLIANCES. | | | | | | 7)NOTE: PLEASE INCLUDE ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH SUBMITTED PANEL | | | SCHEDULES. | | | PLEASE SEE 700.12E FOR CIRCUITING OF EM/ | | | EXT LTS.THE BRANCH CIRCUIT FEEDING THE | | | UNIT EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | 8)NOTE: PLEASE CORRELATE PLANS WITH | | | PANELS AND RISER DIAGRAM. PLEASE SHOW | | | ALL PANELS ON PLANS. | | | PLEASE SEE 110.26,408.7 ETC | | | | | | PLEASE SEE OTHER POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE BE SURE TO REMOVE ALL OLD/VOIDED | | | SHEETS SND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW AND | | | STMAPING. ONE SET OF OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANYQUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2005-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-07 |
Time |
14:01 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-26 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-26 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2006-01-26 00:00:00 | REVISION DATED 11/1/05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-29 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-29 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2005-09-29 00:00:00 | LIFE SAFETY SHEETS STAMPED | | | | | | PASSED ON 7/11/05 BY MEC. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-07-11 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-07-11 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-31 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-31 |
Time |
11:24 |
Sent To |
P |
|
| Notes |
| 2006-03-31 00:00:00 | TO "PSCHMITZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-16 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-16 |
Time |
11:48 |
Sent To |
P |
|
| Notes |
| 2006-03-16 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-13 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-13 |
Time |
14:17 |
Sent To |
B |
|
| Notes |
| 2006-02-13 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-31 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-31 |
Time |
15:34 |
Sent To |
E |
|
| Notes |
| 2006-01-31 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
11:14 |
Sent To |
B |
|
| Notes |
| 2006-01-22 00:00:00 | TO "JWITMER' DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-01 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-01 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2005-12-20 00:00:00 | TO "COMM" BD#3 | | 2005-12-01 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-21 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-21 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | TO "COMM" BD#21 | | 2005-09-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-07 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-07-01 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | TO "COMM" BD#23 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-25 |
Time |
13:42 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2005-07-25 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | NO MECHANICAL CONTRACTOR OR WORK | | | INDICATED WITH PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-03-31 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-31 |
Time |
13:06 |
Sent To |
PC |
|
| Notes |
| 2006-03-31 00:00:00 | SHTA.01 REVISION TO REST ROONS #114,115 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-03-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-03-25 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-25 |
Time |
06:34 |
Sent To |
PC |
|
| Notes |
| 2006-03-25 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODE PLAN | | | REVIEW | | | DENIED | | | 1)SHT. A5.01 REVISION DATED 03-01-06 | | | | | | ?11-4.17 TOILET STALLS. | | | EXCEPTION: NEW CONSTRUCTION | | | (1) THE STANDARD ACCESSIBLE | | | RESTROOM STALL SHALL CONTAIN AN | | | ACCESSIBLE LAVATORY WITHIN IT, THE | | | SIZE OF SUCH LAVATORY TO BE NOT | | | LESS THAN 19 INCHES WIDE BY 17 | | | INCHES DEEP, NOMINAL SIZE, AND WALL | | | MOUNTED.THE LAVATORY SHALL BE | | | MOUNTED SO AS NOT TO OVERLAP THE | | | CLEAR FLOOR SPACE AREAS REQUIRED | | | BY ?11-4.17 (SEE FIGURE 11-30(A) | | | AND FIGURE 11-30(E)) AND TO COMPLY | | | WITH ?11-4.19 OF THE CODE.SUCH | | | LAVATORIES SHALL BE COUNTED AS | | | PART OF THE REQUIRED FIXTURE COUNT FOR | | | THE BUILDING. | | | (2) THE ACCESSIBLE WATER CLOSET | | | SHALL BE LOCATED IN THE CORNER, | | | DIAGONAL TO THE DOOR. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-02-25 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-02-25 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2006-02-25 00:00:00 | INFORMATION ON SITE PLAN #05110890 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-08-05 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-08-05 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | PLUMBING PLAN REVIEW FBC2001 | | | EXISTING REST RM'S PER SCOTT | | | 954-899-6081 | | | END OF COMMENTS,PES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-07 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
lshapiro |
Date |
2006-02-01 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2006-02-01 00:00:00 | APPROVAL OF THIS PERMIT IS SUBJECT TO | | | REVISIONS TO PERMIT 05110890 (LANDSCAPE, | | | SITE PLAN, ELEVATIONS) |
|
|