Review Stop AD ADDRESSING
Rev No 1 Status N Date 2006-02-08 Cont ID  
Sent By alange Date 2006-02-08 Time 16:27 Rev Time 0.00
Received By alange Date 2006-02-08 Time 16:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-02-08 Cont ID  
Sent By alange Date 2006-02-08 Time 16:27 Rev Time 2.00
Received By alange Date 2006-02-08 Time 14:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-01-05 Cont ID  
Sent By alange Date 2006-01-05 Time 09:21 Rev Time 0.50
Received By alange Date 2006-01-05 Time 09:10 Sent To  
Notes
2006-01-05 00:00:00DENIED
  
 1.PRODUCT APPROVALS MISSING.
 SUBMIT TWO COPIES OF PRODUCT APPROVALS
 FOR ROOFING, EXTERIOR DOORS, WINDOWS,
 IMPACT PROTECTION, LINTELS AND STRAPS
 AND TIE-DOWNS.
 ALL PRODUCT APPROVALS SUBMITTED SHALL
 HAVE THE FOLLOWING STATE PRODUCT
 APPROVALS ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-01-05 Cont ID  
Sent By alange Date 2005-09-22 Time 09:06 Rev Time 0.75
Received By alange Date 2005-09-22 Time 09:06 Sent To  
Notes
2006-01-05 00:00:00DENIED
  
 1. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-04 Cont ID  
Sent By alange Date 2005-08-04 Time 14:37 Rev Time 2.50
Received By alange Date 2005-08-04 Time 14:37 Sent To B
Notes
2005-08-04 00:00:00DENIED
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.PLEASE SIGN OWNER/AGENT ON ENERGY
 CALCS.
  
 3. A OF A/7 WALLSECTION DOES NOT SHOW
 PARTY WALL SECTION UP TO BOTTOM OF ROOF
 AS SHOWN IN B OF A/8.PLEASE CLEARIFY.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE SET OF
 OLD PAGES FOR COMPARISON.A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUM- BER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICA TION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
2005-07-23 00:00:00NO MECHANICAL PLANS SUBMITTED WITH
 APPLICATION.ENERGY CALCULATIONS AND
 MANUAL J WERE SUBMITTED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-09-12 Cont ID  
Sent By btrobaug Date 2005-09-12 Time 13:16 Rev Time 0.50
Received By btrobaug Date 2005-09-12 Time 12:35 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-07-21 Cont ID  
Sent By btrobaug Date 2005-07-21 Time 13:24 Rev Time 1.00
Received By btrobaug Date 2005-07-21 Time 13:04 Sent To M
Notes
2005-07-21 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE INDICATE THE CONDUCTOR AND
 CONDUIT SIZE FROM THE DISCONNECT TO THE
 PANEL, ON THE RISER. ALSO NOTE AN
 EQUIPMENT GROUND PER 250.122 IS REQUIRED
 PAST THE FIRST MEANS OF DISCONNECT.
  
 2} THE SMALL APPLIANCE CIRCUITS MUST BE
 CALCULATED AT 1500VA PER 210.11(C)(1).
  
 3} THE GEC MUST BE RAN TO FOOTER STEEL
 PER 2580.50.
  
 4} SMOKE DETECTORS ARE REQUIRED ON THE
 FIRST FLOOR IN CLOSE PROXIMETY TO THE
 STAIRWELL PER 905.2.2 FBC.
  
 5} THE MASTER BEDROOM AND BEDROOM #3
 NEED RECEPTACLES ADDED TO COMPLY WITH
 210.52((A)(1&2) SPACING REQUIREMENTS.
  
 6} THE MASTER BATHROOM NEEDS A
 RECEPTACLE ADDED TO COMPLY WITH
 210.52(D).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-07-24 Cont ID  
Sent By adarroug Date 2008-07-24 Time 14:03 Rev Time 0.00
Received By adarroug Date 2008-07-24 Time 14:03 Sent To Z
Notes
2008-07-24 14:04:23TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-13 Cont ID  
Sent By adarroug Date 2007-08-13 Time 14:28 Rev Time 0.00
Received By adarroug Date 2007-08-13 Time 14:28 Sent To M
Notes
2007-08-13 14:29:15TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-12-30 Cont ID  
Sent By adarroug Date 2005-12-30 Time 08:59 Rev Time 0.00
Received By adarroug Date 2005-12-30 Time 08:59 Sent To B
Notes
2005-12-30 00:00:00TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-09 Cont ID  
Sent By adarroug Date 2005-09-09 Time 16:02 Rev Time 0.00
Received By adarroug Date 2005-09-09 Time 16:02 Sent To E
Notes
2005-09-09 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-14 Cont ID  
Sent By adarroug Date 2005-07-14 Time 08:17 Rev Time 0.00
Received By adarroug Date 2005-07-14 Time 08:17 Sent To E
Notes
2005-07-14 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-04 Cont ID  
Sent By alange Date 2005-08-04 Time 14:37 Rev Time 0.00
Received By alange Date 2005-07-01 Time 16:31 Sent To  
Notes
2005-07-01 00:00:00TO "Z" BOX

Review Stop L LANDSCAPING
Rev No 1 Status P Date 2008-07-29 Cont ID  
Sent By rkussner Date 2008-07-29 Time 13:27 Rev Time 0.00
Received By rkussner Date 2008-07-29 Time 13:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-09-12 Cont ID  
Sent By tgordon Date 2007-09-12 Time 12:08 Rev Time 0.00
Received By tgordon Date 2007-09-12 Time 12:08 Sent To  
Notes
2007-09-12 12:09:34MECHANICAL PLANS SUBMITTED AND FILED WITH MECH. PERMIT
 #07080345.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-08-14 Cont ID  
Sent By tgordon Date 2007-08-14 Time 09:01 Rev Time 0.30
Received By tgordon Date 2007-08-14 Time 09:01 Sent To  
Notes
2007-08-14 09:32:49PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER
 1 CITY OF WEST PALM BEACH AMENDMENTS.
  
 *** DENIED ***
 1) PLANS ON FILE ARE SEALED BY AN ARCHITECT (ALBERT A.
 GARGIULO) SO ONLY HE CAN MAKE REVISION TO HIS PLANS.
  
 2) SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC
 13-101.2.1.
  
 3) SUBMIT COOLING LOAD CALCULATIONS, SEE 2004 FBC
 13-607.1.ABC.1.
  
 4) STATE WHAT H/S RXBH24A10J STANDS FOR.
  
 5) SHOW SEER OF A/C SYSTEM ON PLAN, SEE 2004 FBC
 13-607.1.ABC.3.2.1.
  
 6) SHOW HEATER SIZE ON PLAN.
  
 7) ELECTRICAL PLAN ON FILE SHOWS EXHAUST FANS IN ALL
 BATHROOMS, IF SO SHOW ON MECHANICAL PLAN IF NOT REVISE
 ELECTRICAL PLAN, SEE 2004 FBC/R R303.3 EXCEPT.
  
 8) SHOW CFM'S AT ALL BATHROOM EXHAUST FANS, SEE 2004
 FBC?R R303.3 EXCEPT.
  
 9) MECHANICAL PLAN SUBMITTED SHOWS A/C IN UNIT AR ONLY,
 THIS WILL REQUIRE A REVISION AND MORE FEES IF A/C IS TO
 BE INSTALLED IN UNIT A ALSO.
  
 10) PLEASE ADJUST THE VALUE ON THE BUILDING PERMIT TO
 INCLUDE THE A/C AND PAY THE ADDITIONAL FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL: [email protected].

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-09-12 Cont ID  
Sent By jleech Date 2005-09-12 Time 13:25 Rev Time 0.25
Received By jleech Date 2005-09-12 Time 13:25 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-07-23 Cont ID  
Sent By jleech Date 2005-07-23 Time 09:46 Rev Time 0.33
Received By jleech Date 2005-07-23 Time 09:46 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-07-13 Cont ID  
Sent By mmclean Date 2005-07-13 Time 11:10 Rev Time 0.00
Received By mmclean Date 2005-07-13 Time 11:10 Sent To I
Notes
***NONE***