| Plan Review Stops For Permit 05061767 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-07-11 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jhiggins |
Date |
2005-07-11 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2005-06-29 00:00:00 | NEED EXTENSION PERMIT APPL READS 324 N | | | OLIVE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-22 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-07-22 |
Time |
14:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-11 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-07-11 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2005-07-11 00:00:00 | DENIED | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) EXISTING WALLS APPEAR TO BE PART OF | | | EGRESS ACCESS CORRIDORS, WHICH ARE | | | REQUIRED TO HAVE A ONE HOUR FIRE RATING. | | | SPECIFY FIRE RATING OF WALLS ON THE | | | PLAN. SEE FBC 704.2.4. | | | | | | 3) IF THE WALL ON THE FIRST FLOOR IS | | | REQUIRED TO HAVE A ONE HOUR FIRE RATING | | | SPECIFY THAT THE NEW DOOR HAS A FIRE | | | PROTECTION RATING OF 20 MIN. AS REQUIRED | | | BY FBC 705.1.3.2.2. | | | | | | 4) THE WALLS ON THE THIRD FLOOR ARE | | | REQUIRED TO EXTEND TO THE ROOF DECK OR | | | FLOOR ABOVE, UNLESS THE CEILING IS PART | | | OF AN ASSEMBLY WITH A FIRE RATING AT | | | LEAST EQUAL TO THE WALL. SEE FBC | | | 704.2.1.3. | | | | | | IF YOU HAVE QUESTIONS CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-25 |
Time |
10:37 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-07-25 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | NEW ELECTRICLA SHEETS, | | | RE-STAMPED FOR MINOR CHANGES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-30 |
Time |
19:43 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-06-30 |
Time |
19:43 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | PASSED PENDING ADDRESSING CORRECTION. | | | PLEASE SEE APPLICATION HAS 324 N OLIVE | | | ANS OUR SYSTEM FOR THIS PCN HAS 310 N. | | | OLIVE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-26 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-26 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-05 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-05 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2005-07-05 00:00:00 | ******PASSED****** | | | | | | 1) DRAWINGS RED LINED REGARDING CODE | | | EDITIONS. | | | | | | 2) APPROVED PENDING CORRECT ADDRESSING | | | CLARIFICATION. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 805-6722 OR 835-2951 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-26 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-26 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2005-06-29 00:00:00 | OK PER GRACE JOYCE 6-29-05 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-18 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-18 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | TO "BOB" #5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-11 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-06-30 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | TO "INT REMOD" BD#3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-25 |
Time |
10:44 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-07-25 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH PERMIT APPLICATION, | | | PLEASE NOTE THE FOLLOWING: | | | | | | 1.PLAN SHEET A-2 DETAIL OF THE 3RD | | | FLOOR OVERALL PLAN INDICATES CORRIDOR TO | | | HAVE A 1 HR RATING.FIRE DAMPERS WILL | | | BE REQUIRED IN THE DIFFUSERS PER 2001 | | | FBC(M)607.2. | | | | | | 2.PLAN SHEET A-2 DETAIL OF THE | | | EXISTING CLASSROOM INDICATES EXTENDING | | | THE EXISTING DUCTWORK AND PROVIDING NEW | | | GRILLE.PLEASE NOTE, SHOULD DUCTWORK | | | PENETRATE THE 1 HR PARTITION A FIRE | | | DAMPER WILL BE REQUIRED OR OR DUCT | | | INSTALLATION SHALL COMPLY WITH 2001 | | | FBC(M)607.1.3 #3 ITEMS 1 THROUGH 4. | | | | | | 3.PLEASE PROVIDE PLANS WITH MECHANICAL | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-11 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-07-11 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2005-07-11 00:00:00 | OK PER P. KRAUSS |
|
|