Plan Review Details - Permit 05061767
Plan Review Stops For Permit 05061767
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2005-07-11 Cont ID  
Sent By jhiggins Date 2005-07-11 Time 14:02 Rev Time 0.00
Received By jhiggins Date 2005-07-11 Time 14:02 Sent To  
Notes
2005-06-29 00:00:00NEED EXTENSION PERMIT APPL READS 324 N
 OLIVE

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-07-22 Cont ID  
Sent By rmcdouga Date 2005-07-22 Time 14:15 Rev Time 0.00
Received By rmcdouga Date 2005-07-22 Time 14:15 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-11 Cont ID  
Sent By rmcdouga Date 2005-07-11 Time 13:26 Rev Time 0.00
Received By rmcdouga Date 2005-07-11 Time 13:26 Sent To  
Notes
2005-07-11 00:00:00DENIED
 1)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) EXISTING WALLS APPEAR TO BE PART OF
 EGRESS ACCESS CORRIDORS, WHICH ARE
 REQUIRED TO HAVE A ONE HOUR FIRE RATING.
 SPECIFY FIRE RATING OF WALLS ON THE
 PLAN. SEE FBC 704.2.4.
  
 3) IF THE WALL ON THE FIRST FLOOR IS
 REQUIRED TO HAVE A ONE HOUR FIRE RATING
 SPECIFY THAT THE NEW DOOR HAS A FIRE
 PROTECTION RATING OF 20 MIN. AS REQUIRED
 BY FBC 705.1.3.2.2.
  
 4) THE WALLS ON THE THIRD FLOOR ARE
 REQUIRED TO EXTEND TO THE ROOF DECK OR
 FLOOR ABOVE, UNLESS THE CEILING IS PART
 OF AN ASSEMBLY WITH A FIRE RATING AT
 LEAST EQUAL TO THE WALL. SEE FBC
 704.2.1.3.
  
 IF YOU HAVE QUESTIONS CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-25 Cont ID  
Sent By dpalmer Date 2005-07-25 Time 10:37 Rev Time 0.20
Received By dpalmer Date 2005-07-25 Time 10:37 Sent To  
Notes
2005-07-25 00:00:00NEW ELECTRICLA SHEETS,
 RE-STAMPED FOR MINOR CHANGES.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-06-30 Cont ID  
Sent By dpalmer Date 2005-06-30 Time 19:43 Rev Time 0.25
Received By dpalmer Date 2005-06-30 Time 19:43 Sent To  
Notes
2005-06-30 00:00:00PASSED PENDING ADDRESSING CORRECTION.
 PLEASE SEE APPLICATION HAS 324 N OLIVE
 ANS OUR SYSTEM FOR THIS PCN HAS 310 N.
 OLIVE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-07-26 Cont ID  
Sent By mwennerg Date 2005-07-26 Time 09:58 Rev Time 0.00
Received By mwennerg Date 2005-07-26 Time 09:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-07-05 Cont ID  
Sent By mwennerg Date 2005-07-05 Time 09:17 Rev Time 0.00
Received By mwennerg Date 2005-07-05 Time 09:17 Sent To  
Notes
2005-07-05 00:00:00******PASSED******
  
 1) DRAWINGS RED LINED REGARDING CODE
 EDITIONS.
  
 2) APPROVED PENDING CORRECT ADDRESSING
 CLARIFICATION.
  
  
 MIKE WENNERGREN, A/CAPTAIN
 WPBFR(561) 805-6722 OR 835-2951

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-07-26 Cont ID  
Sent By mwennerg Date 2005-07-26 Time 09:53 Rev Time 0.00
Received By mwennerg Date 2005-07-26 Time 09:53 Sent To  
Notes
2005-06-29 00:00:00OK PER GRACE JOYCE 6-29-05

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-18 Cont ID  
Sent By adarroug Date 2005-07-18 Time 14:52 Rev Time 0.00
Received By adarroug Date 2005-07-18 Time 14:52 Sent To  
Notes
2005-07-18 00:00:00TO "BOB" #5

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-11 Cont ID  
Sent By rmcdouga Date 2005-07-11 Time 14:31 Rev Time 0.00
Received By rmcdouga Date 2005-06-30 Time 15:04 Sent To  
Notes
2005-06-30 00:00:00TO "INT REMOD" BD#3

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2005-07-25 Cont ID  
Sent By pkrauss Date 2005-07-25 Time 10:44 Rev Time 0.35
Received By pkrauss Date 2005-07-25 Time 10:44 Sent To  
Notes
2005-07-25 00:00:00NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED WITH PERMIT APPLICATION,
 PLEASE NOTE THE FOLLOWING:
  
 1.PLAN SHEET A-2 DETAIL OF THE 3RD
 FLOOR OVERALL PLAN INDICATES CORRIDOR TO
 HAVE A 1 HR RATING.FIRE DAMPERS WILL
 BE REQUIRED IN THE DIFFUSERS PER 2001
 FBC(M)607.2.
  
 2.PLAN SHEET A-2 DETAIL OF THE
 EXISTING CLASSROOM INDICATES EXTENDING
 THE EXISTING DUCTWORK AND PROVIDING NEW
 GRILLE.PLEASE NOTE, SHOULD DUCTWORK
 PENETRATE THE 1 HR PARTITION A FIRE
 DAMPER WILL BE REQUIRED OR OR DUCT
 INSTALLATION SHALL COMPLY WITH 2001
 FBC(M)607.1.3 #3 ITEMS 1 THROUGH 4.
  
 3.PLEASE PROVIDE PLANS WITH MECHANICAL
 PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-11 Cont ID  
Sent By rmcdouga Date 2005-07-11 Time 13:54 Rev Time 0.00
Received By rmcdouga Date 2005-07-11 Time 13:54 Sent To  
Notes
2005-07-11 00:00:00OK PER P. KRAUSS