Plan Review Details - Permit 05061669
| Plan Review Stops For Permit 05061669 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-17 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-11 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2007-07-17 10:09:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)BASED ON APPLICATION DATE OF JUNE 27, 2005, | | | GOVERNING CODE SHOULD BE FBC2001.EITHER SUBMIT A NEW | | | APPLICATION OR REVISE TO FBC2001.CODE RQUIREMENTS ARE | | | THE SAME FOR BUILDING REVIEW, BUT CODE REFERENCES MAY | | | DIFFER. | | | | | | 2.)THE HANDRAIL EXTENSION AT THE BOTTOM OF THE STAIR | | | IS TO COMPLY WITH FBC1009.11.5, EXTEND HORIZONTALLY FOR | | | AT LEAST 12INCHES BEYOND THE BOTTOM RISER. | | | | | | 3.)PROVIDE A GUARD DETAIL FOR THE LOFT, FBC1012. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-23 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-22 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2007-03-23 11:46:33 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | NOTE - NEW PLANS FROM A NEW DESIGN | | | PROFESSIONAL, 2ND -4TH REVIEW FOR NEW DOR | | | | | | NOTE - FIRST PLAN REVIEWS WERE DONE ON FBC2001 AS A | | | PLAN CHECK.GOVERNING CODE FOR THE PROJECT WILL BE | | | FBC2004; CODE REFERENCES HAVE BEEN REVISED. | | | | | | WHEN RESUBMITTING,PLEASE INCLUDE A RESPONSE LETTER | | | INDICATING HOW THE ITEMS WERE ADDRESSED.ALSO INCLUDE | | | A SET OF OLD SHEETS. | | | | | | FROM PREVIOUS LISTS: | | | | | | 1.) ADDRESSED. | | | | | | 2.) IMPACT FEES MAY BE DUE (CHANGE OF | | | USE).THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 4TH REVIEW - THE RECEIPT AND THE STAMPED PLAN ARE | | | REQUIRED.A RECEIPT FOR $14,880 WAS PROVIDED BUT IT IS | | | FOR WASHINGTON MUTUAL BANK, DOES NOT APPEAR TO BE THE | | | RECEIPT FOR THIS PROJECT. | | | | | | 3. - 12.)ADDRESSED. | | | | | | 13.)SHOW COMPLIANCE WITH FBC1007, ALL | | | DETAILS - STAIR WIDTH, TREAD AND RISER | | | DIMENSIONS FBC1007, ALL REQUIREMENTS OF | | | FBC1006.2, HANDRAIL AND GUARDRAIL | | | DIMENSIONS FBC1007 AND FBC1015, HANDRAIL | | | AND GUARDRAIL DESIGN CRITERIA (FBC1608). | | | | | | THE RESPONSE LETTER STATES THAT THE STAIR RAIL WILL BE | | | AT 42", 34-38" REQUIRED.THE PLAN HAS A NOTE WHICH | | | STATES "34"MIN 38" MAX" BUT DOES NOT STATE WHAT THIS IS | | | FOR.THERE IS A NOTE, THE NEW HANDRAIL SHALL EXTEND 8" | | | AT BOTTOM AND 12" HORIZONTALLY AT TOP.THE DETIAL MUST | | | COMPLY WITH THE REQUIREMENTS OF FBC1009.11.5.THE | | | GUARD IS SHOWN AT 48". | | | | | | 14. - 17.)ADDRESSED. | | | | | | 18.)PREVIOUS LISTS QUESTIONED COMPLIANCE WITH | | | MEZZANINE REQUIREMENTS.NOTE THAT YOU NOW CALL THIS AN | | | ATTIC, BUT AN ATTIC IS UNCONDITIONED AREA BETWEEN FLOOR | | | SPACE AND THE ROOF ABOVE; THIS IS CLEARLY NOT AN ATTIC. | | | PLEASE PROPERLY DEFINE THIS AREA. | | | | | | 19.)SHOW FIRE RATING REQUIREMENT FOR | | | THE DOORS WITHIN 10FT OF THE STAIRS, | | | FBC705.1.2.PROVIDE FIRE RATING | | | INFORMATION FOR THE SPECIFIC DOOR YOU | | | ARE INSTALLING. | | | | | | THE ELEVATION STATES THIS IS A 1 HOUR DOOR, THE | | | SCHEDULE SPECIFIES A 1 1/2 HOUR DOOR.FIRE RESISTANCE | | | REQUIREMENTS FOR OTHER OPENINGS ARE NOT NOTED ON THE | | | PLAN (WINDOWS, DOOR ON THE SECOND FLOOR). | | | | | | 20.)SHOW ALL DETAILS AND DESIGN LOAD REQUIREMENTS FOR | | | THE MEZZANINE.WAS THE | | | ORIGINAL MEZZANINE PERMITTED LIKE THIS? | | | | | | THE AREA IS NOW CALLED AN "ATTIC", PLEASE SEE ITEM 29. | | | DESIGN LOADS NOT PROVIDED. SHOW DESIGN LOADS FOR THIS | | | AREA, REGARDLESS OF WHAT IT IS LABELED; FBC TABLE | | | 1604.1. | | | | | | 4TH REQUEST, PROVIDE DESIGN LOADS (DEAD LOAD AND LIVE | | | LOAD) FOR THE MECHANICAL MEZZANINE AREA. | | | | | | 21.)PROVIDE AREA CALCULATIONS FOR THE | | | SPACE.IT IS NOT CLEAR IF THE MEZZANINE | | | WAS INCLUDED WHEN IMPACT FEES WERE PAID. | | | | | | 3RD REVIEW - AREA CALCS PROVIDED CALLING THIS AREA AS A | | | MECH ATTIC.IMPACT FEE ASSESSMENT BY THE COUNTY NOT | | | DONE, SEE ITEM 2 ABOVE. | | | | | | 22.)PROVIDE WIND DESIGN CRITERIA | | | REQUIRED BY FBC1606.1.7. | | | | | | 3RD REVEIW - WRONG CODE SPECIFIED BASED ON APPLLICATION | | | DATE. | | | | | | 4TH REVIEW - WRONG CODE SPECIFIED BASED ON APPLICATION | | | DATE.THIS PROJECT MUST BE DESIGNED TO FBC2004; IT HAS | | | AN APPLICATION DATE OF JANUARY 2007. | | | | | | 23-26.)ADDRESSED. | | | | | | 27.)SHOW REQUIRED TENANT/OCCUPANCY | | | SEPARATION BETWEEN THE LAUNDROMAT AND | | | THE RESTAURANT.DECLARE AN OCCUPANCY | | | FOR THE RESTAURANT. | | | | | | NOT ADDRESSED.THE SEPARATION BETWEEN THE RESTAURANT | | | AND THE 2ND FLOOR STATES 5/8 TYPE X DRYWALL, DOES NOT | | | STATE HOW MANY LAYERS.YOU SPECIFY A 1 HOUR, BUT 5/8 | | | TYPE X IS 40 MINUTES. | | | | | | 4TH REVIEW - THE PLAN STATES THIS IS 2 HOURS, 2 LAYERS, | | | BUT 2 LAYERS IS 80 MINUTES.SEE FBC 302.3.1, FBC | | | 708.1(5), FBC708.3, FBC708.4.DESIGN INTENT SHOULD BE | | | CLEAR ON THE PLAN. | | | | | | 28.)SEE ATTACHED FS553.80(2)(B). | | | | | | 29.)THE MECHANICAL ROOM IS NOT AN ATTIC, SEE | | | DEFINITIONS FBC13-202.IS THIS A MEZZANINE?TO BE | | | TREATED AS ANOTHER FLOOR?CODE COMPLIANCE CANNOT BE | | | DETERMINED UNTIL DOR DETERMINES HOW TO CLASSIFY THE | | | SPACE.NOTE THAT A NEW AREA IS BEING CREATED AND A | | | CODE COMPLIANT MEANS OF EGRESS MUST SERVE THAT AREA. | | | SHEET 5 STILL CALLS IT A MEZZANINE. | | | | | | 30-31.)ADDRESSED. | | | | | | 32.)PRODUCT APPROVALSWERE SUBMITTED FOR SHUTTERS. | | | USE OF REMOVABLE SHUTTERS MUST BE APPROVED BY THE | | | BUILDING OFFICIAL, SEE ATTACHED POLICY, ITEM 13.WHAT | | | ARE THE SHUTTERS FOR?THE DOORS ARE IMPACT.THE PLAN | | | DOES NOT SHOW WINDOW REPLACEMENT.NO SHUTTER | | | INSTALLATION PLAN WAS SUBMITTED. | | | | | | NEW COMMENT: | | | | | | 33.)STORAGE IS SHOWN UNDER THE STAIRS; THIS MUST | | | COMPLY WITH FBC1019.1.5.NOTE THAT THIS COMMENT WAS | | | MADE ON THE FIRST REVIEW AND THE EQUIPMENT/STORAGE | | | REMOVED FROM THE PLAN.PROVIDE INFORMATION IN REGARDS | | | TO WHAT WILL BE STORED UNDER THE STAIRS AND SHOW | | | COMPLIANCE WITH FBC1019.1.5. | | | | | | 34.)A HARD NONABSORBENT FINISH REQUIRED FOR THE | | | BATHROOM AS REQUIRED BY FBC1210.2. | | | | | | 35.)DECLARE OCCUPANT LOAD FOR THE RESTAURANT AREA AND | | | FOR THE MEZZANINE, FBC1004.1.IF THE METHOD USED TO | | | ESTABLISH OCCUPANT LOAD IS NOT CLEAR, PROVIDE | | | CALCULATIONS FOR EACH AREA. | | | | | | 36.)THERE IS A NOTE ON THE PLAN STATING THAT THE | | | ARCHITECT IS TO INSPECT ROTTED FLOOR JOISTS.THIS WILL | | | BE ISSUED WITH A PROVISO THAT AN INSPECTION IS REQUIRED | | | PRIOR TO CONCEALING THIS AREA. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-18 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-18 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2006-10-18 14:25:07 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | NOTE - NEW PLANS FROM A NEW DESIGN | | | PROFESSIONAL, 2ND REVIEW FOR THIS DOR | | | | | | WHEN RESUBMITTING,PLEASE INCLUDE A RESPONSE LETTER | | | INDICATING HOW THE ITEMS WERE ADDRESSED.SOME | | | QUESTIONS WERE NOT ANSWERED. | | | | | | FROM PREVIOUS LIST: | | | | | | 1.) ADDRESSED. | | | | | | 2.) IMPACT FEES MAY BE DUE (CHANGE OF | | | USE).THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 2ND REVIEW - THE RECEIPT WAS IN THE PACKAGE BUT THE | | | PLANS WERE NOT STAMPED.WHEN | | | RESUBMITTING, PLEASE BE SURE THAT BOTH | | | ITEMS ARE INCLUDED. | | | | | | 3RD REVIEW - THE RECEIPT AND THE STAMPED PLAN ARE | | | REQUIRED, NEITHER ARE IN THE PACKAGE. | | | | | | 3. - 7.)ADDRESSED. | | | | | | 8.-12.)ADDRESSED. | | | | | | 13.)SHOW COMPLIANCE WITH FBC1007, ALL | | | DETAILS - STAIR WIDTH, TREAD AND RISER | | | DIMENSIONS FBC1007, ALL REQUIREMENTS OF | | | FBC1006.2, HANDRAIL AND GUARDRAIL | | | DIMENSIONS FBC1007 AND FBC1015, HANDRAIL | | | AND GUARDRAIL DESIGN CRITERIA (FBC1608). | | | | | | THIS WAS ADDRESSED BUT THE STAIRRAIL IS NOT COMPLIANT. | | | STAIR RISER APPEARS NON COMPLIANT.AS AREA HAS NOT | | | BEEN PROPERLY CLASSIFIED, CODE COMPLIANCE CANNOT BE | | | DETERMINED. | | | | | | 14. - 15.)ADDRESSED. | | | | | | 16-17.)ADDRESSED. | | | | | | 18.)N/A, NO LONGER CALLED A MEZZANINE. | | | | | | 19.)SHOW FIRE RATING REQUIREMENT FOR | | | THE DOORS WITHIN 10FT OF THE STAIRS, | | | FBC705.1.2.PROVIDE FIRE RATING | | | INFORMATION FOR THE SPECIFIC DOOR YOU | | | ARE INSTALLING. | | | | | | 20.)SHOW ALL DETAILS AND DESIGN LOAD REQUIREMENTS FOR | | | THE MEZZANINE.WAS THE | | | ORIGINAL MEZZANINE PERMITTED LIKE THIS? | | | | | | THE AREA IS NOW CALLED AN "ATTIC", PLEASE SEE ITEM 29. | | | DESIGN LOADS NOT PROVIDED. SHOW DESIGN LOADS FOR THIS | | | AREA, REGARDLESS OF WHAT IT IS LABELED; FBC TABLE | | | 1604.1. | | | | | | 21.)PROVIDE AREA CALCULATIONS FOR THE | | | SPACE.IT IS NOT CLEAR IF THE MEZZANINE | | | WAS INCLUDED WHEN IMPACT FEES WERE PAID. | | | | | | 3RD REVIEW - AREA NOW CALLED ATTIC, PROVIDE AREA. | | | | | | 22.)PROVIDE WIND DESIGN CRITERIA | | | REQUIRED BY FBC1606.1.7. | | | | | | 3RD REVEIW - WRONG CODE SPECIFIED BASED ON APPLLICATION | | | DATE. | | | | | | DECLARE A GOVERNING CODE ON THE PLAN.IF YOU WISH AT | | | THIS TIME TO SWITCH TO FBC2004, RESUBMIT WITH NEW | | | APPLICATOIN. | | | | | | PLAN STATES C&C DESIGN PRESSURES, "SEE PLAN", CANNOT | | | LOCATE ON THIS PLAN. | | | | | | 23-24.)ADDRESSED. | | | | | | 25.)PREVIOUS PLANS MADE REFERENCE TO | | | ACCESSING THE MEZZANINE FROM THE OTHER | | | TENANT SPACE.WHAT HAPPENED TO THIS | | | OPENING, NO LONGER SHOWN ON THE PLAN? | | | | | | 26.)OLD PLANS SHOWNO LANDING ON THE | | | STAIRS, THIS PLAN SHOWS A LANDING. | | | ADDRESS. | | | | | | 27.)SHOW REQUIRED TENANT/OCCUPANCY | | | SEPARATION BETWEEN THE LAUNDROMAT AND | | | THE RESTAURANT.DECLARE AN OCCUPANCY | | | FOR THE RESTAURANT. | | | | | | NOT ADDRESSED.THE SEPARATION BETWEEN THE RESTAURANT | | | AND THE 2ND FLOOR STATES 5/8 TYPE X DRYWALL, DOES NOT | | | STATE HOW MANY LAYERS.YOU SPECIFY A 1 HOUR, BUT 5/8 | | | TYPE X IS 40 MINUTES. | | | | | | 28.)SEE ATTACHED FS553.80(2)(B). | | | | | | NEW COMMENT: | | | | | | 29.)THE MECHANICAL ROOM IS NOT AN ATTIC, SEE | | | DEFINITIONS FBC13-202.IS THIS A MEZZANINE?TO BE | | | TREATED AS ANOTHER FLOOR?CODE COMPLIANCE CANNOT BE | | | DETERMINED UNTIL DOR DETERMINES HOW TO CLASSIFY THE | | | SPACE.NOTE THAT A NEW AREA IS BEING CREATED AND A | | | CODE COMPLIANT MEANS OF EGRESS MUST SERVE THAT AREA. | | | SHEET 5 STILL CALLS IT A MEZZANINE. | | | | | | 30.)SHOW HEIGHT OF THE DOOR AT THE LANDING. | | | | | | 31.)THE PLAN SHOWS A MECHANICAL PLATFORM OUTSIDE OF | | | THE BUILDING, "8' ANDER THE BUILDING".PROVIDE A | | | COMPLETE DETAIL INCLUDING DESIGN LOAD CRITERIA.PLAN | | | STATES "SEE DETAIL 1", CANNOT LOCATED. ZONING REVIEW | | | REQUIRED. | | | | | | 32.)PRODUCT APPROVALS SUBMITTED ARE FOR NON IMPACT | | | WITH SHUTTERS.USE OF REMOVABLE SHUTTERS MUST BE | | | APPROVED BY THE BUILDING OFFICIAL, SEE ATTACHED POLICY, | | | ITEM 13. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-13 |
Time |
10:32 |
Rev Time |
2.50 |
| Received By |
shill |
Date |
2006-03-10 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | NOTE - NEW PLANS FROM A NEW DESIGN | | | PROFESSIONAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | THE NOC IS EXPIRED, OVER 90 DAYS WITHOUT | | | COMMENCING WORK, FS713.13(2). | | | | | | 2.) IMPACT FEES MAY BE DUE (CHANGE OF | | | USE).THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | THE RECEIPT WAS IN THE PACKAGE BUT THE | | | PLANS WERE NOT STAMPED.WHEN | | | RESUBMITTING, PLEASE BE SURE THAT BOTH | | | ITEMS ARE INCLUDED. | | | | | | 3.)THE KITCHEN IS TO BE CONSTRUCTED SO | | | THAT INDIVIDUALS WITH DISABILITIES CAN | | | APPROACH, ENTER, AND EXIT THE AREA | | | FBC11-4.1.1(3).DOOR IS TO COMPLY WITH | | | FBC11-4.13. | | | | | | THIS WAS APPARENTLY ADDRESSED.THE | | | ARCHITECT SENT A RESPONSE LETTER STATING | | | "THE DEPARTMENT OF BUSINESS | | | ADMINISTRATION INSISTED THAT THE KITCHEN | | | IS CLOSED OFF BY A DOOR."WHAT DOES | | | THIS MEAN? | | | | | | 4. - 7.)ADDRESSED. | | | | | | 8.)PROVIDE ELEVATIONS TO SHOW | | | ACCESSIBLE ROUTE; APPEARS TO HAVE A STEP | | | UP INTO THE BUILDING. | | | | | | ELEVATIONS NOT PROVIDED.SLOPES NOT | | | PROVIDED. | | | | | | 9. - 12.)ADDRESSED. | | | | | | 13.)HOW WILL THE A/C BE ACCESSED?THE | | | NOTE ON THE PLAN IS CONFUSING; STATES TO | | | ACCESS THROUGH THE LAUNDRY ON 2ND FLOOR, | | | BUT ISN'T THE LAUNDRY ON THE FIRST | | | FLOOR? | | | | | | SHOW COMPLIANCE WITH FBC1007, ALL | | | DETAILS - STAIR WIDTH, TREAD AND RISER | | | DIMENSIONS FBC1007, ALL REQUIREMENTS OF | | | FBC1006.2, HANDRAIL AND GUARDRAIL | | | DIMENSIONS FBC1007 AND FBC1015, HANDRAIL | | | AND GUARDRAIL DESIGN CRITERIA (FBC1608). | | | | | | THE DOOR IS AN 80IN DOOR, BUT THE | | | DIMENSION FROM THE LANDING TO THE SECOND | | | FLOOR SCALED IS APPROXIMATELY 72IN | | | TOTAL, INCLUDING THE FLOOR/CEILING | | | ASSEMBLY.ADDRESS. | | | | | | 14. - 15.)ADDRESSED. | | | | | | 16.)TWO MEANS OF EGRESS REQUIRED; | | | TRAVEL DISTANCE EXCEEDS 50' FBC1025.1. | | | | | | THE TWO EXIT DOORS ARE LESS THAN HALF | | | THE DIAGONAL DISTANCE APART, | | | FBC1004.1.4.WHAT ARE THE TWO MEANS OF | | | EGRESS FOR THE PERSON IN THE KITCHEN | | | AREA TO THE REAR (SINKS)? | | | | | | 17.)THE HC RR DOOR BLOCKS THE EGRESS, | | | FBC1012.1.4. | | | | | | IF THIS IS USED AS SECOND MEANS OF | | | EGRESS FOR THE PERSON IN THE REAR | | | KITCHEN AREA, THE COMMENT STILL APPLIES. | | | | | | NEW COMMENTS: | | | | | | 18.)SEE FBC1003.2.5 AND SHOW | | | COMPLIANCE FOR THE MEZZANINE CEILING | | | HEIGHT. | | | | | | 19.)SHOW FIRE RATING REQUIREMENT FOR | | | THE DOORS WITHIN 10FT OF THE STAIRS, | | | FBC705.1.2.PROVIDE FIRE RATING | | | INFORMATION FOR THE SPECIFIC DOOR YOU | | | ARE INSTALLING. | | | | | | 20.)SHOW ALL DETAILS AND DESIGN LOAD | | | REQUIREMENTS FOR THE MEZZANINE.WAS THE | | | ORIGINAL MEZZANINE PERMITTED LIKE THIS? | | | | | | 21.)PROVIDE AREA CALCULATIONS FOR THE | | | SPACE.IT IS NOT CLEAR IF THE MEZZANINE | | | WAS INCLUDED WHEN IMPACT FEES WERE PAID. | | | | | | 22.)PROVIDE WIND DESIGN CRITERIA | | | REQUIRED BY FBC1606.1.7. | | | | | | 23.)THERE IS A BATHROOM SHOWN IN THE | | | ADJACENT TENANT SPACE, PROP.EX.RR. | | | PROPOSED EXISTING REST ROOM?WHAT DOES | | | THIS MEAN? | | | | | | 24.)MECHANICAL EQUIPMENT IS SHOWN | | | UNDER THE STAIRS, THE ONLY MEANS OF | | | EGRESS FOR THE RESIDENTIAL OCCUPANTS ON | | | THE SECOND FLOOR.THIS CREATES A FIRE | | | HAZARD, SEE FBC1007 AND FBC1001.1.4. | | | | | | 25.)PREVIOUS PLANS MADE REFERENCE TO | | | ACCESSING THE MEZZANINE FROM THE OTHER | | | TENANT SPACE.WHAT HAPPENED TO THIS | | | OPENING, NO LONGER SHOWN ON THE PLAN? | | | | | | 26.)OLD PLANS SHOWNO LANDING ON THE | | | STAIRS, THIS PLAN SHOWS A LANDING. | | | ADDRESS. | | | | | | 27.)SHOW REQUIRED TENANT/OCCUPANCY | | | SEPARATION BETWEEN THE LAUNDROMAT AND | | | THE RESTAURANT.DECLARE AN OCCUPANCY | | | FOR THE RESTAURANT. | | | | | | 28.)SEE ATTACHED FS553.80(2)(B). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-05 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
|
Date |
2005-08-05 |
Time |
08:16 |
Sent To |
Z |
|
| Notes |
| 2005-08-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.) IMPACT FEES MAY BE DUE (CHANGE OF | | | USE).THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 3.)THE KITCHEN IS TO BE CONSTRUCTED SO | | | THAT INDIVIDUALS WITH DISABILITIES CAN | | | APPROACH, ENTER, AND EXIT THE AREA | | | FBC11-4.1.1(3).DOOR IS TO COMPLY WITH | | | FBC11-4.13. | | | | | | 4.) THE SINK HOT WATER PIPES (HC RR) | | | SHALL BE INSULATED OR OTHERWISE | | | CONFIGURED SO AS TO PROTECT AGAINST | | | CONTACT, FBC11-4.24.6. | | | | | | 5.)FIXED SEATING IS TO COMPLY WITH | | | FBC11-5.1, FBC11-4.32.SHOW COMPLIANCE | | | ON THE PLAN. | | | | | | 6.)SHOW FRONT AND SIDE CLEAR FLOOR | | | SPACE FOR THE WATER CLOSET, | | | FBC11-4.16.2, FBC11 FIGURE 28. | | | | | | 7.)DOOR HARDWARE TO COMPLY WITH | | | 11-4.13.9. | | | | | | 8.)PROVIDE ELEVATIONS TO SHOW | | | ACCESSIBLE ROUTE; APPEARS TO HAVE A STEP | | | UP INTO THE BUILDING. | | | | | | 9.)SHOW DOOR DIMENSIONS AND CLEARANCE. | | | | | | 10.)NOTE THE DOOR CONSTRUCTION TYPE. | | | IF IT IS WOOD, RODENT PROOFING REQUIRED | | | FBC1205.1.1. | | | | | | 11.)WHERE WILL THE EXHAUST DISCHARGE? | | | WILL THEY GO THROUGH ANOTHER TENANT | | | SPACE? | | | | | | 12.)DECLARE AN OCCUPANCY FOR THE 2ND | | | FLOOR. | | | | | | 13.)HOW WILL THE A/C BE ACCESSED?THE | | | NOTE ON THE PLAN IS CONFUSING; STATES TO | | | ACCESS THROUGH THE LAUNDRY ON 2ND FLOOR, | | | BUT ISN'T THE LAUNDRY ON THE FIRST | | | FLOOR? | | | | | | 14.)THE SEAL IS TO BE DATED | | | FAC61G15-23.002. | | | | | | 15.)DECLARE AN OCCUPANT LOAD. | | | | | | 16.)TWO MEANS OF EGRESS REQUIRED; | | | TRAVEL DISTANCE EXCEEDS 50' FBC1025.1. | | | | | | 17.)THE HC RR DOOR BLOCKS THE EGRESS, | | | FBC1012.1.4. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-24 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-24 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2007-06-24 10:00:02 | | | | *** UNSAT 5TH REVIEW*** | | | | | | ** PLEASE SEE THERE ARE STILL MANY ITEMS FROM PREVIOUS | | | REVIEWS WHICH STILL NEED TO BE ADDRESSED. | | | PLEASE ALSO SEE SOME NEW NOTES AS SOME INFORMATION HAS | | | BEEN ADDED TO PLANS AND SOME INFORMATION ON PREVIOUS | | | PLANS AHS NOW BEEN REMOVED. | | | | | | | | | 1) NOTE: PLEASE BE SURE PLANS CONTAIN ALL THE RELEVANT | | | CODES AND YEARS IN WHICH THE PLANS ARE DESIGNED UNDER. | | | THIS WAS NOT DONE IN FACT THE PLANS STILL STATE THE | | | 2004 FBC WHICH THIS PROJECT IS NOT PERMITTED UNDER. | | | PLEASE SEE THE MISPRINTS FOR THE NFPA AND NEC. | | | PLEASE SEE COMMENT FOR LOAD CALCULATIONS AS CODE(S) | | | STATED ARE NOT FROM THE 2002 NEC WHICH IS WHAT THIS | | | PROJECT IS PERMITTED UNDER. | | | | | | THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY ANY | | | OTHER TRADE. | | | ** THIS IS UNDER THE 2001 FBC \ | | | THE FOLLOWING MINIMUM CODES SHALL BE SHOWN ON PLANS | | | WHICH ARE RELEVANT TO THE DESIGN OF PROJECT. | | | 2001 FBC, 2002 NFPA-70(NEC), 2003 NFPA-101, 2002 | | | NFPA-72 (WHERE APPLICABLE). | | | | | | 2) NOTE: THIS IS THE SAME COMMENT AS PREVIOUS REVIEW. | | | PLEASE SEE PLANS STILL ARE MISSING MANY ITEMS NOT | | | CIRCUITED. PLEASE SEE SEVERAL LIGHTS WHICH ARE SHOWN ON | | | E-2 BUT NOT ON LIGHTING PLANS ON FIRST FLOOR AND NO | | | CIRCUITING FOR ANY OF THESE. PLEASE SEE COMMENT FOR | | | EMERGENCY LIGHTS ETC. | | | | | | **PREVIOUS REVIEW NOTE** | | | PLEASE SHOW AND COMPLETE ALL CIRCUITING ON PLANS AND | | | CORRELATE WITH THE SUBMITTED PANEL SCHEDULE. THIS WAS | | | STILL NOT DONE; THERE ARE SEVERAL ITEMS ON PLANS WHICH | | | DO NOT CONTAIN CIRCUITS. PLEASE ALSO SEE CIRCUIT(S) ON | | | PLANS WHICH DO NOT GO TO ANYTHING? PLEASE SEE THAT THE | | | PANEL SCHEDULE SHALL BE SPECIFIC TO ALL CIRCUITS AND | | | AREAS WHICH THEY FEED. PLEASE BE SURE THE CIRCUITS ON | | | SCHEDULE CORRELATES TO THE PLANS FOR ANY ROOM AND AREA | | | DESIGNATIONS. THIS REQUIRES THAT THE IDENTIFICATION FOR | | | EVERY CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD | | | BE LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION. | | | FBC104.3.1.1 ADMIN SECT 2001. | | | NEC 408.4, 240.4, 310.16 | | | | | | 3) NOTE:THIS NOTE REMAINS AS CIRCUITING HAS NOT BEEN | | | COMPLETED ON PLANS AND REVIEW FOR COMPLIANCE CAN NOT BE | | | DONE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 700.12F AS THE EM AND EXT LTS SHALL BE | | | CIRCUITED TO THE BRANCH CIRCUIT LIGHTING IN ANY ONE | | | AREA WHERE THESE FIXTURES ARE LOCATED. | | | PLEASE ALSO SEE COMMENT WITH RESPECT TO FIXTURES AND | | | TYPES. | | | THIS COMMENT WAS MADE ON PREVIOUS REVIEW FOR | | | CIRCUITING. | | | | | | 4) NOTE:PLEASE SEE THE LOAD CALCULATIONS AS SUBMITTED | | | ARE NOT CORRECT. PLEASE SEE THE 2002 NEC AND SHOW LOAD | | | CALCULATIONS PER NEC. THE LOAD CALCULATIONS AS SHOWN DO | | | NOT COORDINATE WITH THE NEC. PLEASE SEE THE NEC HAS | | | SEVERAL EXAMPLES WHICH CAN BE USED. | | | PLEASE SEE THE SHOW WINDOW LOADS DO NOT SEEM TO | | | CORRELATE. | | | PLEASE SEE THE INCORRECT CODE IS BEING QUOTED. (SHOULD | | | BE 2002 NEC). | | | PLEASE SEE NOT ALL CONTINUOUS LOADS ARE SHOWN AT 125%. | | | | | | *PREVIOUS REVIEW NOTE ** | | | PLEASE SHOW LOAD CALCULATIONS, WHICH ARE IN COMPLIANCE | | | WITH THE 2002 NEC SECTION. 220. | | | THIS WAS NOT DONE; THE CALCULATIONS SUBMITTED ARE NOT | | | CODE COMPLIANT IN ANY FASHION. | | | PLEASE INDICATE HOW LOADS WERE DERIVED ON A LOAD | | | SUMMARY BASED FROM THE NEC. 220. | | | 220.3,220.10,220.11,220.12 220.13, ALL CONTINUOUS LOADS | | | 125% PER 215.3, 230.42 AND LARGEST MOTOR LOAD. PLEASE | | | INCLUDE ALL EXISTING LOADS WITH NEW LOADS BEING ADDED. | | | WHERE IS THE REST OF THE SERVICE FOR BUILDING WHICH | | | THIS TENANT IS BEING ADDED TO EXISTING??? | | | | | | 5) NOTE: THIS NOTE IS THE SAME. THE RESPONSE MENTIONS | | | THERE IS SITE/PUBLIC LIGHTING WHICH PROVIDES THE | | | LIGHTING, HOWEVER IT IS NOT PERMITTED TO RELY ON THE | | | PUBLIC LIGHTING AND QUOTING THE CODE ON PLANS FOR THE | | | CONTRACTOR TO PROVIDE THIS IN LIEU OF SHOWING THE | | | REQUIRED MINIMUM LEVELS IS NOT PERMITTED. | | | PLEASE SEE EMERGENCY LIGHTING ON PLANS WHICH DO NOT | | | INDICATE CIRCUITS, FIXTURES WHICH ON FIXTURE LEGEND | | | ONLY INDICATES BEING AN EXIT LIGHT AND NOT A | | | COMBINATION UNIT. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CLARIFY MEANS OF EGRESS LIGHTING REQUIRED FOR | | | REAR OF BLDG TO THE PUBLIC RIGHT OF WAY. THIS INCLUDES | | | A BACK UP FIXTURE OF SOME TYPE. A NOTE ON PLANS WHICH | | | MENTIONS LIGHTING TO BE INSTALLED DOES NOT COMPLY WITH | | | SHOWING THE MINIMUM AS REQUIRED IN DESIGN. LS 101 2003, | | | 7.8.1.3, 7.9.2.2. PLEASE KNOW, A MIN OF 10FT CANDLES IS | | | REQUIRED UNDER NORMAL AND 1FT CANDLE UNDER EM | | | CONDITIONS. PLEASE SHOW. | | | | | | 6) NOTE: PLEASE SEE THE PREVIOUS PLANS SUBMITTED THE | | | ELECTRICAL RISER AS NEEDED HOWEVER THERE WERE SEVERAL | | | ITEMS WHICH WERE NOT NEC COMPLIANT. PLEASE SEE THE | | | PLANS ARE NOW MISSING THE RISER ALL TOGETHER?? PLEASE | | | SUBMIT A COMPLETED ELECTRICAL RISER DIAGRAM NEW OR | | | EXISTING WHICH IS CODE COMPLIANT. | | | | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE NEW RISER SUBMITTED WHICH IS NOT CODE | | | COMPLIANT. | | | PLEASE SEE THE SERVICE ENTRANCE CONDUCTOR SIZES ALONG | | | WITH FEEDERS ARE NOT OF SUFFICIENT SIZE TO CONFORM TO | | | NEC 310.16. | | | PLEASE SEE SOME OF THE CONDUCTOR SIZES AS SHOWN ARE NOT | | | A STANDARD CONDUCTOR SIZE FROM THE STANDARDS OF AWG | | | (AMERICAN WIRE GAUGE) OR NEC 310.16. | | | PLEASE SEE SOME OF THE CONDUCTORS ARE ONLY RATED FOR | | | 200AMPS. | | | PLEASE SEE NOTE WHICH MENTIONS *TO PANEL POLE* ? WHAT | | | IS THIS? | | | PLEASE COMPLETE CONDUCTORS IN GUTTER AND THE REST OF | | | THE SERVICE. PLEASE SHOW ON PLANS. | | | PLEASE INDICATE SIZE OF METER CAN/SERVICE BEING | | | PROVIDED. PLEASE SEE NOTE #4 ABOVE. | | | | | | ? PLEASE SEE 240.4, 230.2, 110.26, 240.24, 408.7, | | | 215.5, 230.70, 240.6, ETC. | | | ? THERE ARE TOO MANY SECTIONS TO LIST. | | | | | | | | | 7) NOTE:AS NOT RISER WAS SUBMITTED REVIEW FOR THIS | | | PREVIOUS NOTE CAN NOT BE DONE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING EQUIPMENT GROUNDING CONDUCTOR AFTER | | | THE FIRST MEANS OF DISCONNECT. AS THE SERVICE SHOWN IS | | | NOT CLEAR FOR THE REST OF THE SERVICE, IT IS UNCLEAR | | | WHAT AND WHERE EQUIPMENT GROUNDS ARE FOR THE SERVICE | | | AND HOW THEY ARE TO BE INSTALLED AS NOT OTHER EQUIPMENT | | | IS BEING SHOWN FOR THE SERVICE. PLEASE SEE 250.66, | | | 250.6, 250.24B, 250.110, 250.50, 250.104 | | | AS THE GROUNDING ELECTRODE SYSTEM IS NOT COMPLETE AT | | | THIS TIME. | | | | | | 8) NOTE:PLEASE SEE THAT THE LIGHTING FIXTURES ON | | | PLANS DO NOT CORRELATE WITH THE FIXTURE LEGEND | | | PROVIDED. PLEASE SEE THE FIXTURE LEGEND DOES NOT | | | PROVIDE ANY FIXTURE INFORMATION. PLEASE SEE THE PLANS | | | DO NOT LABEL LIGHTS FOR TYPE OR EVEN AN ALPHA/NUMERIC | | | DESIGNATION WHICH CORRELATES TO THE FIXTURE LEGEND?? | | | MANY ITEMS FOR REVIEW OF CODE COMPLIANCE NEED TO BE | | | DONE. | | | **PREVIOUS REVIEW NOTE** | | | PLEASE PROVIDE AND A SYMBOL/FIXTURE LEGEND. UNABLE TO | | | REVIEW FIXTURES FOR EM / EXT, ARE THESE COMBO UNITS?? | | | | | | 9) NOTE: THIS WAS NOT DONE. RESPONSE MENTIONS TO SEE | | | PICTURES, HOWEVER NOT PICTURES WERE LOCATED AND PLANS | | | STILL ARE REQUIRED TO SHOW THIS. | | | 110.26, 408.7, 240.24 ETC. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SHOW LOCATION OF THE EXISTING SERVICE. PLEASE | | | ALSO SHOW AND INDICATE THE LOAD ON THE EXISTING SERVICE | | | WITH NEW LOAD ADDED. AS NOTED ABOVE IN NOTE #4 AND NOTE | | | #6. | | | 220 NEC | | | FBC ADMIN SECT 104.3.1.1 | | | | | | 10) NOTE: PLEASE SEE THE PLANS NOW INDICATE THE CU AND | | | DISCONNECT FOR THE UNIT ON THE SIDE OF BUILDING. THE | | | PLANS ALSO STATE ON THE ROOF WHICH BY REVIEW OF PLANS | | | PLACES THIS UNIT ON THE ROOF WHICH IS NOT PART OF THIS | | | BUILDING. THIS UNIT MAY NOT BE LOCATED ON ADJACENT | | | PROPERTY/BUILDING ROOF. AS THE UNIT HAS STILL NOT BEEN | | | SHOWN ON PLANS FOR LOCATION AND IT SEEMS THE UNIT COULD | | | BE LOCATED ON A SEPARATE PROPERTY FURTHER INFORMATION | | | IS NEEDED. | | | 440.11, 110.26, ETC. | | | | | | 11) NOTE:PLEASE SEE NOT ENERGY CALCULATIONS WERE | | | SUBMITTED AND THE RESPONSE WAS THAT THESE ARE NOT | | | NEEDED. PLEASE SEE THAT ANY CHANGE IN OCCUPANCY | | | REQUIRES COMPLIANCE NOT ONLY WITH CHAPTER 13 OF THE FBC | | | BUT ALL ELECTRICAL TECHNICAL CODES. | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE THAT THIS BEING A CHANGE IN OCCUPANCY; | | | PLEASE SUBMIT COMPLETE ENERGY CALCULATIONS WHICH COMPLY | | | WITH THE 2001 FBC CHAPTER 13. | | | THIS WAS NOT SUBMITTED AS REQUIRED PER 415.ABCD AND | | | 415.2 ETC. | | | | | | 12) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | | PLEASE SEE AS SEVERAL COMMENTS STILL REMAIN A 4X FEE | | | FOR THE PLAN REVIEW PORTION OF THE BASE PERMIT FEE HAS | | | BEEN ASSESSED. THE AMOUNT OF $1080.00 WILL BE DUE UPON | | | RE-SUBMITTAL OF THE PLANS. THIS FEE IS THE | | | RESPONSIBILITY OF THE DESIGNER OF RECORD AND NOT THE | | | CONTRACTOR OR OWNER AS STATED IN THE FLORIDA STATUTES. | | | ** PLEASE KNOW THAT ONE SET OF PLANS ARE BEING RETAINED | | | AND WILL BE PLACED WITH PREVIOUSLY RETAINED PLANS. | | | | | | 13) NOTE: PLEASE SEE THE APPLIED VALUE FOR THE COMPLETE | | | SCOPE OF WORK INCLUDING ALL LABOR, MATERIALS, | | | PERMANENTLY INSTALLED EQUIPMENT; DESIGN COST FOR PLANS | | | IS LOW. THIS IS REQUIRED WHETHER OR NOT ANY OF THESE | | | ITEMS ARE OWNER SUPPLIED. | | | PLEASE SEE 104.6.5 UNDER THE 2001 FBCADMIN SECTION AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-11 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-11 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2007-02-11 14:48:09 | *** UNSAT 4TH REVIEW*** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEWS WHICH STILL | | | NEED TO BE ADDRESSED ALONG WITH NEW NOTES AS STATED | | | BELOW. | | | | | | | | | 1) NOTE: PLEASE BE SURE PLANS CONTAIN ALL THE RELEVANT | | | CODES AND YEARS IN WHICH THE PLANS ARE DESIGNED UNDER. | | | | | | THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY ANY | | | OTHER TRADE. | | | ** THIS IS UNDER THE 2001 FBC \ | | | THE FOLLOWING MINIMUM CODES SHALL BE SHOWN ON PLANS | | | WHICH ARE RELEVANT TO THE DESIGN OF PROJECT. | | | 2001 FBC, 2002 NFPA-70(NEC), 2003 NFPA-101, 2002 | | | NFPA-72 (WHERE APPLICABLE). | | | | | | 2 ) NOTE: PLEASE SHOW AND COMPLETE ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED PANEL SCHEDULE. | | | THIS WAS STILL NOT DONE; THERE ARE SEVERAL ITEMS ON | | | PLANS WHICH DO NOT CONTAIN CIRCUITS. PLEASE ALSO SEE | | | CIRCUIT(S) ON PLANS WHICH DO NOT GO TO ANYTHING? PLEASE | | | SEE THAT THE PANEL SCHEDULE SHALL BE SPECIFIC TO ALL | | | CIRCUITS AND AREAS WHICH THEY FEED. PLEASE BE SURE THE | | | CIRCUITS ON SCHEDULE CORRELATES TO THE PLANS FOR ANY | | | ROOM AND AREA DESIGNATIONS. THIS REQUIRES THAT THE | | | IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | | PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | | SECTION. | | | FBC104.3.1.1 ADMIN SECT 2001. | | | NEC 408.4, 240.4, 310.16 | | | | | | 3) NOTE: PLEASE SEE 700.12E AS THE EM AND EXT LTS SHALL | | | BE CIRCUITED TO THE BRANCH CIRCUIT LIGHTING IN ANY ONE | | | AREA WHERE THESE FIXTURES ARE LOCATED. | | | PLEASE ALSO SEE COMMENT WITH RESPECT TO FIXTURES AND | | | TYPES. | | | THIS COMMENT WAS MADE ON PREVIOUS REVIEW FOR | | | CIRCUITING. | | | | | | 4) NOTE: PLEASE SHOW LOAD CALCULATIONS, WHICH ARE IN | | | COMPLIANCE WITH THE 2002 NEC SECTION. 220. | | | THIS WAS NOT DONE; THE CALCULATIONS SUBMITTED ARE NOT | | | CODE COMPLIANT IN ANY FASHION. | | | PLEASE INDICATE HOW LOADS WERE DERIVED ON A LOAD | | | SUMMARY BASED FROM THE NEC. 220. | | | 220.3,220.10,220.11,220.12 220.13, ALL CONTINUOUS LOADS | | | 125% PER 215.3, 230.42 AND LARGEST MOTOR LOAD. PLEASE | | | INCLUDE ALL EXISTING LOADS WITH NEW LOADS BEING ADDED. | | | WHERE IS THE REST OF THE SERVICE FOR BUILDING WHICH | | | THIS TENANT IS BEING ADDED TO EXISTING??? | | | | | | 5) NOTE: PLEASE CLARIFY MEANS OF EGRESS LIGHTING | | | REQUIRED FOR REAR OF BLDG TO THE PUBLIC RIGHT OF WAY. | | | THIS INCLUDES A BACK UP FIXTURE OF SOME TYPE. A NOTE ON | | | PLANS WHICH MENTIONS LIGHTING TO BE INSTALLED DOES NOT | | | COMPLY WITH SHOWING THE MINIMUM AS REQUIRED IN DESIGN. | | | LS 101 2003, 7.8.1.3, 7.9.2.2. PLEASE KNOW, A MIN OF | | | 10FT CANDLES IS REQUIRED UNDER NORMAL AND 1FT CANDLE | | | UNDER EM CONDITIONS. PLEASE SHOW. | | | | | | 6) NOTE: PLEASE SEE NEW RISER SUBMITTED WHICH IS NOT | | | CODE COMPLIANT. | | | PLEASE SEE THE SERVICE ENTRANCE CONDUCTOR SIZES ALONG | | | WITH FEEDERS ARE NOT OF SUFFICIENT SIZE TO CONFORM TO | | | NEC 310.16. | | | PLEASE SEE SOME OF THE CONDUCTOR SIZES AS SHOWN ARE NOT | | | A STANDARD CONDUCTOR SIZE FROM THE STANDARDS OF AWG | | | (AMERICAN WIRE GAUGE) OR NEC 310.16. | | | PLEASE SEE SOME OF THE CONDUCTORS ARE ONLY RATED FOR | | | 200AMPS. | | | PLEASE SEE NOTE WHICH MENTIONS *TO PANEL POLE* ? WHAT | | | IS THIS? | | | PLEASE COMPLETE CONDUCTORS IN GUTTER AND THE REST OF | | | THE SERVICE. PLEASE SHOW ON PLANS. | | | PLEASE INDICATE SIZE OF METER CAN/SERVICE BEING | | | PROVIDED. PLEASE SEE NOTE #4 ABOVE. | | | | | | ? PLEASE SEE 240.4, 230.2, 110.26, 240.24, 408.7, | | | 215.5, 230.70, 240.6, ETC. | | | ? THERE ARE TOO MANY SECTIONS TO LIST. | | | | | | | | | 7) NOTE: PLEASE SEE MISSING EQUIPMENT GROUNDING | | | CONDUCTOR AFTER THE FIRST MEANS OF DISCONNECT. AS THE | | | SERVICE SHOWN IS NOT CLEAR FOR THE REST OF THE SERVICE, | | | IT IS UNCLEAR WHAT AND WHERE EQUIPMENT GROUNDS ARE FOR | | | THE SERVICE AND HOW THEY ARE TO BE INSTALLED AS NOT | | | OTHER EQUIPMENT IS BEING SHOWN FOR THE SERVICE. PLEASE | | | SEE 250.66, 250.6, 250.24B, 250.110, 250.50, 250.104 | | | AS THE GROUNDING ELECTRODE SYSTEM IS NOT COMPLETE AT | | | THIS TIME. | | | | | | 8) NOTE: PLEASE PROVIDE AND A SYMBOL/FIXTURE LEGEND. | | | UNABLE TO REVIEW FIXTURES FOR EM / EXT, ARE THESE COMBO | | | UNITS?? | | | | | | 8) NOTE: PLEASE SHOW LOCATION OF THE EXISTING SERVICE. | | | PLEASE ALSO SHOW AND INDICATE THE LOAD ON THE EXISTING | | | SERVICE WITH NEW LOAD ADDED. AS NOTED ABOVE IN NOTE #4 | | | AND NOTE #6. | | | 220 NEC | | | FBC ADMIN SECT 104.3.1.1 | | | | | | 9) NOTE: PLEASE SEE 424.3B FOR MIN OCP FOR AHU. PLEASE | | | SEE NO MECH PLANS SUBMITTED, UNABLE TO VERIFY THE KW | | | RATING OF THE HEAT. PLEASE VERIFY AS THE 6.5 AS SHOWN | | | DOES NOT SEEM TO BE A TYPICAL SIZE? | | | PLEASE SEE THIS IS THE SAME COMMENT FROM PREVIOUS | | | REVIEW. | | | | | | 10) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. PLEASE KNOW IF ANY | | | OF THE NOTES ABOVE ARE NOTED ON THE FOLLOWING REVIEW | | | FOR COMPLIANCE WHICH HAS NOT BEEN MADE, A FEE FOR PLAN | | | REVIEW WILL BE ASSESSED. | | | THIS IS ONLY NOTED AT THIS TIME. | | | | | | 11) NOTE: PLEASE SEE THAT THIS BEING A CHANGE IN | | | OCCUPANCY, PLEASE SUBMIT COMPLETE ENERGY CALCULATIONS | | | WHICH COMPLY WITH THE 2001 FBC CHAPTER 13. | | | THIS WAS NOT SUBMITTED AS REQUIRED PER 415.ABCD AND | | | 415.2 ETC. | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-10-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-15 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-15 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2006-10-15 09:16:51 | **** UNSAT ***** | | | | | | ** THIS IS UNDER THE 2001 FBC \ | | | THE FOLLOWING MINIMUM CODES SHALL BE SHOWN ON PLANS | | | WHICH ARE RELEVANT TO THE DESIGN OF PROJECT. | | | 2001 FBC, 2002 NFPA-70(NEC), 2003 NFPA-101, 2002 | | | NFPA-72 (IF APPLICABLE). | | | | | | ** PLEASE SEE SOME COMMENTS FROM REVIEW DATED 7/6/05 BY | | | THIS REVIEWER ARE STILL IN NEED OF ADDRESSING. PLEASE | | | ALSO SEE SOME NEW COMMENTS BASED ON PLANS SUBMITTED. | | | | | | 1) NOTE: PLEASE SHOW AND COMPLETE ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED PANEL SCHEDULE. | | | | | | PREVIOUS REVIEW#1 | | | FBC104.3.1.1 ADMIN SECT 2001. | | | | | | 2) NOTE: PLEASE SEE 700.12E AS THE EM AND EXT LTS SHALL | | | BE CIRCUITED TO THE BRANCH CIRCUIT LIGHTING IN ANY ONE | | | AREA WHERE THESE FIXTURES ARE LOCATED. | | | PLEASE ALSO SEE COMMENT WITH RESPECT TO FIXTURES AND | | | TYPES. | | | PREVIOUS REVIEW#1 | | | | | | 3) NOTE: PLEASE SHOW LOAD CALCULATIONS, PLEASE INDICATE | | | HOW LOADS WERE DERIVED ON A LOAD SUMMARY BASED FROM THE | | | NEC. 220. 220.3,220.10,220.11,220.13, ALL CONTINUOUS | | | LOADS 125% PER 215.3, 230.42 AND LARGEST MOTOR LOAD. | | | PREVIOUS REVIEW.#1 | | | | | | 4) NOTE: PLEASE SEE CU'S AND POSSIBLE MISSING | | | DISCONNECTS, GFI RECEPT. 440.11,110.26, 210.63 PREVIOUS | | | REVIEW #1 | | | | | | 5) NOTE: PLEASE CLARIFY MEANS OF EGRESS LIGHTING | | | REQUIRED FOR REAR OF BLDG TO THE PUBLIC RIGHT OF WAY. | | | THIS INCLUDES A BACK UP FIXTURE OF SOME TYPE. | | | LS 101 2003, 7.8.1.3, 7.9.2.2. PLEASE KNOW, A MIN OF | | | 10FT CANDLES IS REQUIRED UNDER NORMAL AND 1FT CANDLE | | | UNDER EM CONDITIONS. PLEASE SHOW. | | | | | | 6) NOTE: PLEASE COMPLETE PANEL SCHEDULE AS ITEM SHOWN, | | | HOWEVER NO LOADS OR OCP ETC. | | | 408.4,310.16 | | | | | | 7) NOTE: PLEASE PROVIDE AND A SYMBOL/FIXTURE LEGEND. | | | UNABLE TO REVIEW FIXTURES FOR EM / EXT, ARE THESE COMBO | | | UNITS?? | | | | | | 8) NOTE: PLEASE SHOW LOCATION OF THE EXISTING SERVICE. | | | PLEASE ALSO SHOW AND INDICATE THE LOAD ON THE EXISTING | | | SERVICE WITH NEW LOAD ADDED. | | | 220 NEC | | | FBC ADMIN SECT 104.3.1.1 | | | | | | 9) NOTE: PLEASE SEE E424.3B FOR MIN OCP FOR AHU. PLEASE | | | SEE NO MECH PLANS SUBMITTED, UNABLE TO VERIFY THE KW | | | RATING OF THE HEAT. PLEASE VERIFY AS THE 6.5 AS SHOWN | | | DOES NOT SEEM TO BE A TYPICAL SIZE? | | | | | | 10) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. AS THIS REVIEWER | | | DID NOT REVIEW THE 2ND SET OF SUBMITTED PLANS, THIS IS | | | ONLY A NOTICE GIVEN AT THIS TIME. | | | | | | ** PLEASE KNOW, AS ELECTRICAL PLUMB BLDG ETC IS MIXED | | | AND NOT ON SEPARATE PLANS/SHEETS, EVEN IF SHEETS ARE | | | PASSED BY OTHER REVIEWERS, THEY MAY BE VOID DUE TO THE | | | CONTENT OF MORE THAN ONE TRADE ON ONE SHEET. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-01-30 |
Time |
08:20 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-01-30 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-06 |
Time |
20:18 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-07-06 |
Time |
20:18 |
Sent To |
|
|
| Notes |
| 2005-07-06 00:00:00 | ********* UNSAT ********* | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH PANEL | | | SCHEDULE(S) TO BE SUBMITTED, | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE PLANS MENTIONS AHU TO | | | BE ACCESIBLE THROUGH LAUNDRY MAT TENANT | | | SPACE. THIS SHALL NOT BE PERMITTED. ALL | | | ACCESS MUST BE FROM TENANT SPACE FOR | | | REST. | | | PLEASE SEE TENANT SEPARATION NOTES ETC | | | FROM FIRE AND BLDG REVIEW. | | | PLEASE SEE NEC FOR ACCESSIBILTY TO | | | ELECTRICAL EQUIPMENT AND DISCONNECTING | | | MEANS. | | | 215.5 | | | | | | 3)NOTE: PLEASE CLARIFY NEW OR EXISTING | | | REQUIRED SIGN CIRCUIT PER 600.5 | | | | | | 4)NOTE: PLEASE SHOW COND UNIT. | | | DISCONNECT, GFI RECEPT ETC REQUIRED, | | | 440.11,210.63 | | | PLEASE ALSO SHOW MISSING LT/RECEPT FOR | | | AHU,210.70,210.63 | | | | | | 5)NOTE: PLEASE CLARIFY NEW OR EXISTING | | | SHOW WINDOW RECEPTS PER 210.62, LOADS TO | | | BE SHOWN PER 220.12. | | | | | | 6)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | FOR NEW LOADS AND EXSITNG LOADS. | | | PLEASE INDICATE SIZE OF SERVICE, | | | CONDUCTORS, GROUNDING, RISER ETC, NEW? | | | EXISTING? | | | 215.5,250.50,310.16,240.4,220 ETC. | | | | | | 7)NOTE: PLEASE SEE 210.8B3, WHICH | | | REQUIRES ALL 15- AND 20-AMPERE, 125-VOLT | | | RECEPTACLES IN NONDWELLING-TYPE KITCHENS | | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | | APPLIES TO EACH AND EVERY 15- AND | | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | | WHETHER OR NOT THE RECEPTACLE SERVES | | | COUNTERTOP APPLIANCES. | | | | | | 8)NOTE: PLEASE SEE TITLE BLOCK MENTIONS | | | ACI, ?? PLEASE CLARIFY? ARCH/ ENGINEERS | | | ETC, CONTRACTOR LISTED ON APPLICATION | | | MENTIONS SOMEONE ELSE. | | | PLEASE SEE FAC 61G1-16.004, FAC | | | 61G15-23.002, FS 481.219, AND 471.023 | | | FOR POSSIBLE INFORMAITON REQUIRED. | | | | | | 9)NOTE: PLEASE SPECIFY OF THIS IS A | | | "CHANGE IN OCCUPANCY". | | | PLEASE SEE OTHER POSSIBE COMMENTS FROM | | | OTHER TRADES WHCIH NAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | PLEASE REMOVE ALL OLD |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-07-02 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-07-02 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2007-07-02 14:12:25 | ***PROVISO*** | | | | | | 1) PLEASE NOTE THAT PLANS STILL REFERENCE CO2 FOR HOOD | | | SUPPRESSION SYSTEM. AS INDICATED IN A PREVIOUS FIRE | | | PLAN REVIEW, THE HOOD SUPPRESSION SYSTEM SHALL BE WET | | | CHEMICAL IN COMPLIANCE WITH UL 300. PLEASE MAKE | | | CORRECTION TO HELP FACILITATE PLANS APPROVAL STAMPING. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-02-23 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-02-23 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2007-02-23 15:48:55 | ***PROVISO*** | | | | | | 1) NEW RAILINGS SHALL MEET THE PRESCRIPTIVE STRENGTH | | | REQUIREMENTS. | | | | | | 2) IN ADDITION TO "K" EXTINGUISHER IN KITCHEN, 2A-10B,C | | | RATED FIRE EXTINGUISHERS ARE REQUIRED. | | | | | | 3) ELEVATIONS DO NOT SHOW ADDRESS ON EXISTING BUILDING. | | | ADDRESS TO MEET SIZE AND CONTRAST REQUIREMENTS IN | | | ACCORDANCE WITH CITY OF WEST PALM BEACH. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW(561) 805-6722 | | | FIRE PREVENTION(561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-31 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-10-31 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2006-10-31 15:43:08 | ***DENIED*** | | | | | | PLEASE NOTE THAT IT DOES NOT APPEAR THAT THE LAST FIRE | | | REVIEW HAS BEEN ADDRESSED. PLEASE SEE THE FOLLOWING | | | TAKEN DIRECTLY FROM THE LAST FIRE REVIEW: | | | | | | 1) SEPARATE PLANS AND PERMITS REQUIRED FOR HOOD, DUCT | | | AND SUPPRESSION SYSTEMS. | | | | | | 2) PLANS MAKE REFERENCE TO A CO2 SYSTEM. THE PLANS | | | SHOULD REFERENCE A WET CHEMICAL SYSTEM THAT COMPLIES | | | WITH UL 300. | | | | | | 3) A SINGLE STAIR IS DISPLAYED ON THE NORTH ELEVATION | | | WHICH IS IN CLOSE PROXIMITY TO DOORS AND WINDOWS. DO | | | ANY OTHER EXITS EXIST FROM THE UPSTAIRS APARTMENTS? IF | | | NOT, A SINGLE MEANS OF EGRESS IS SHOWN WITH UNPROTECTED | | | OPENINGS WITHIN (10) FEET OF THESE STAIRS. PLEASE | | | ADVISE. | | | | | | PLEASE PROVIDE COMMENTS AS THIS WILL HELP EXPEDITE THIS | | | PROCESS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW (561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-02-15 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-02-15 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2006-02-15 00:00:00 | 1. SEPARATE PLANS AND PERMITS REQUIRED | | | FOR HOOD, DUCT, AND SUPPRESSION SYSTEM. | | | | | | 2. PLANS MAKE REFERENCE TO A CO2 SYSTEM. | | | THE PLANS SHOULD REFERENCE A WET | | | CHEMICAL SYSTEM THAT COMPLIES WITH UL | | | 300. | | | | | | 3. A SINGLE STAIR IS DISPLAYED ON THE | | | NORTH ELEVATION WHICH IS IN CLOSE | | | PROXIMITY TO DOORS AND WINDOWS. DOES ANY | | | OTHER EXITS EXIST FROM THE UPSTAIR | | | APARTMENTS. IF NOT, A SINGLE MEANS OF | | | EGRESS IS SHOWN WITH UNPROTECTED | | | OPENINGS WITHIN 10 FEET OF THESE STAIRS. | | | PLEASE ADVISE. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-13 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-13 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | ******DENIED****** | | | | | | 1) THE FLOOR PLAN MENTIONS 42 SEATS. | | | PLEASE ILLUSTRATE HOW THIS WILL BE | | | ACCOMPLISHED ON THE DRAWINGS. | | | | | | 2) WHAT IS THE TOTAL OCCUPANCY LOAD FOR | | | THE ENTIRE SPACE? IF IN EXCESS OF 50, | | | THE DOOR SWINGS ARE INCORRECT, AND MUST | | | SWING IN THE DIRECTION OF TRAVEL. | | | | | | 3) PLANS INDICATE A SINGLE EXIT. DOES | | | THIS SPACE MEET THE REQUIREMENTS TO | | | ALLOW FOR THAT ARRANGEMENT? | | | | | | 4) ELECTRICAL NOTES MENTION SMOKE | | | DETECTORS. IF PROVIDED, PLEASE SHOW | | | LOCATIONS ON THE PLANS. | | | | | | 5) FIRE EXTINGUISHERS ARE REQUIRED. | | | RATING TO BE 2A-10B,C IN SPACE, AND "K" | | | TYPE IN THE KITCHEN. | | | | | | 6) IF NOT ALREADY PROVIDED, A MINIMUM OF | | | 6" HIGH ADDRESS NUMBER IS REQUIRED ON | | | THE BUILDING TO CONTRAST WITH | | | BACKGROUND. PLEASE SHOW ON PLANS. | | | | | | 7) COOKING THAT PRODUCES GREASE LADEN | | | VAPOR REQUIRES A HOOD/SUPPRESSION | | | SYSTEM. SEPARATE SHOP DRAWINGS AND | | | PERMITS ARE REQUIRED FOR HOOD AND | | | SUPPRESSION SYSTEM. | | | | | | 8) IT WOULD APPEAR THAT THIS BUILDING | | | MEETS THE DEFINITION OF MIXED OCCUPANCY. | | | WHAT IS THE CURRENT OCCUPANCY OF THE | | | SECOND FLOOR? | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 805-6722 OR 835-2951 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-09 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-09 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2007-07-09 17:52:12 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | FROM PREVIOUS REVIEWS: 4TH REVIEW | | | *******FROM PREVIOUS REVIEWS: | | | | | | | | | 1. SHT P-1, GAS SYSTEM IS REQUIRED TO HAVE AN EMERGENCY | | | SHUT OFF VALVE FOR COOKING EQUIPMENT. A SHUTOFF VALVE | | | IS REQUIRED UPSTREAM OF THE EMERGENCY VALVE AND A UNION | | | DOWNSTREAM, SO VALVE CAN BE REPLACED OR REPAIRED. | | | ****RESPONSE NOTED, BUT THE FIRST VALVE, (MOST | | | UPSTREAM), IS INDICATED AS THE EMERGENCY SHUT OFF | | | VALVE. THEN THERE IS A GLOBE TYPE FITTING IDENTIFIED AS | | | A UNION. SEE RED LINE EXAMPLE OF A MANUAL SHUT OFF | | | VALVE, A UNION, THEN THE EMERGENCY SHUT OFF VALVE, | | | (SOLINOID VALVE), IN THAT ORDER. | | | *******RESPONSE NOTED AGAIN, BUT THE MANUAL SHUT OFF | | | VALVE IS NOT SHOWN ON THE RISER DIAGRAM. | | | | | | 1. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | | | | 6. SHT P-1, SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE OUTLET IN THE | | | BUILDING AND/OR SYSTEM PER FBC-2001 FUEL GAS CODE | | | APPENDIX A - USE OF CAPACITY TABLES (A)(3). | | | ****RESPONSE NOTED, BUT THE INFORMATION IS NOT | | | INDICATED ON THE PLANS. NOT ADDRESSED. ******RESPONSE | | | NOTED, BUT THE DISTANCE IS NOT INDICATED ON SHT P-1. | | | | | | 7. OK | | | | | | 8. SHT P-1, SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND THE FBC-2001 FUEL GAS CODE SECTION 402.2. | | | ****RESONSE NOTED, BUT THE INDICATE THE MODEL NUMBERS | | | FOR THE GRIDDLE, THE RANGE, AND THE BOILER. THE BTU | | | LOADS FOR THESE GAS APPLIANCES DO NOT REFLECT ANY OF | | | THE MODEL NUMBERS SHOWN. THE MANUFACTURE SPECIFICATION | | | SHEETS FOR THE GAS WATER HEATER HAVE NOT BEEN | | | SUBMITTED. | | | ******RESPONSE NOTED, BUT THIS HAS NOT BEEN ADDRESSED. | | | THE BTU'S SHOWN ON THE RISER DIAGRAM DO NOT REFLECT THE | | | BTU'S SHOWN ON THE MANUF. SPECIFICATION SHEETS AND THE | | | MODELS ARE NOT INDICATED ON THE MANUF. SHEETS. STILL NO | | | MANUF. SHEETS FOR THE WATER HEATER. | | | | | | | | | ************NEW COMMENT********** | | | | | | 1B. FOUR TIMES THE FEE WOULD HAVE BEEN ACCESSED ON THIS | | | PLAN REVIEW IF ELECTRICAL PLAN REVIEWER HAD NOT ALREADY | | | DONE SO. IF THE COMMENTS ARE NOT ADDRESSED WHEN | | | RESUBMITTING NEXT TIME, ANOTHER FOUR TIMES THE FEE WILL | | | BE ACCESS AGAIN ON THE NEXT RESUBMITTAL. FS | | | 533.80(2)(B). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-27 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-27 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2007-02-27 11:10:59 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | FROM PREVIOUS REVIEWS: 4TH REVIEW | | | | | | 1. SHT P-1, GAS SYSTEM IS REQUIRED TO HAVE AN EMERGENCY | | | SHUT OFF VALVE FOR COOKING EQUIPMENT. A SHUTOFF VALVE | | | IS REQUIRED UPSTREAM OF THE EMERGENCY VALVE AND A UNION | | | DOWNSTREAM, SO VALVE CAN BE REPLACED OR REPAIRED. | | | ****RESPONSE NOTED, BUT THE FIRST VALVE, (MOST | | | UPSTREAM), IS INDICATED AS THE EMERGENCY SHUT OFF | | | VALVE. THEN THERE IS A GLOBE TYPE FITTING IDENTIFIED AS | | | A UNION. SEE RED LINE EXAMPLE OF A MANUAL SHUT OFF | | | VALVE, A UNION, THEN THE EMERGENCY SHUT OFF VALVE, | | | (SOLINOID VALVE), IN THAT ORDER. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | ****RESPONSE NOTED, BUT THERE ARE SECTIONS THAT SHOW NO | | | LENGTH MEASUREMENT. SHOW THE DISTANCE FROM THE METER TO | | | FIRST RISER, THE DISTANCE FROM THE BOTTOM OF THE FIRST | | | RISER TO THE TOP, AND FROM THE TOP OF THE FIRST RISER | | | TO THE START OF THE 7'0" LENGTH OF PIPE IN THE CEILING. | | | (SEE HIGHLIGHTED SECTIONS ON ONE SET OF PLANS). | | | | | | 3. OK | | | | | | 4. SHT P-1 TYPE OF GAS, (LP OR NATURAL) ****RESPONSE | | | NOTED, BUT PLEASE INDICATE ON THE PLANS. | | | | | | 5. OK | | | | | | 6. SHT P-1, SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE OUTLET IN THE | | | BUILDING AND/OR SYSTEM PER FBC-2001 FUEL GAS CODE | | | APPENDIX A - USE OF CAPACITY TABLES (A)(3). | | | ****RESPONSE NOTED, BUT THE INFORMATION IS NOT | | | INDICATED ON THE PLANS. NOT ADDRESSED. | | | | | | 7. OK | | | | | | 8. SHT P-1, SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND THE FBC-2001 FUEL GAS CODE SECTION 402.2. | | | ****RESONSE NOTED, BUT THE INDICATE THE MODEL NUMBERS | | | FOR THE GRIDDLE, THE RANGE, AND THE BOILER. THE BTU | | | LOADS FOR THESE GAS APPLIANCES DO NOT REFLECT ANY OF | | | THE MODEL NUMBERS SHOWN. THE MANUFACTURE SPECIFICATION | | | SHEETS FOR THE GAS WATER HEATER HAVE NOT BEEN | | | SUBMITTED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-10-28 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-10-28 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-10-28 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2006-10-28 07:06:30 | PAUL SCHMITZ, PLUMBING & GAS PLANS | | | EXAMINER561-805-6692 | | | | | | [email protected] | | | PLUMBING GAS PLAN REVIEW FBC 2001 | | | | | | DENIED | | | | | | PREVIOUS NOTES FOR GAS NOT ADDRESSED | | | | | | WHEN RESUBMITTING. | | | PLEASE INCLUDE A RESPONCE LETTER INDICATING HOW THE | | | ITEMS WERE ADDRESSED, THIS WILL HELP TO EXPIDITE THE | | | PLAN REVIEW. | | | | | | (1) SHT 2, GAS SYSTEM IS REQUIRED TO HAVE A EMERGENCY | | | SHUT OFF VALVE FOR COOKING | | | EQUIPMENT. A SHUTOFF VALVE IS REQUIRED UP STREAM STREAM | | | OF THE EMERGENCY VALVE | | | AND A UNION DOWN STREAM, SO VALVE CAN BE REPLACED OR | | | REPAIRED. | | | | | | (2)SHT 2, PROVIDE A GAS PIPING ISOMETRICSUBMIT AN | | | ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL CUT SECTIONS | | | OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 FUEL GAS CODE. | | | | | | (3) SHT 2,SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH NUMBER OF | | | CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | (4) SHT 2, TYPE OF GAS, (LP OR NATURAL) | | | | | | (5) SHT 2, BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU | | | LOAD ON THE SYSTEM. REFER TO THE FBC-2001 FUEL GAS CODE | | | SECS. 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU 402(34). | | | | | | (6) SHT 2,SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE OUTLET IN THE | | | BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | | | | (7) SHT 2,INDICATE THE DELIVERY PRESSURE (PSI) PER | | | FBC-2001 FUEL GAS CODE SEC. 402.2. NATURAL GAS SPECIFY | | | .5 PSI OR 2 PSI. | | | | | | (8) SHT 2, SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | | | | END OF COMMENTS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-05 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-05 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2007-06-21 14:32:46 | TO "COMM" BD#26 | | 2007-06-05 15:24:27 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-29 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-29 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2007-02-07 08:30:20 | TO "COMM" BD#33 | | 2007-01-29 15:14:11 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
17:01 |
Sent To |
|
|
| Notes |
| 2006-10-12 13:42:15 | TO "COMM" BD#8 | | 2006-09-23 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-13 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-13 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-05 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-05 |
Time |
18:21 |
Sent To |
Z |
|
| Notes |
| 2005-08-05 00:00:00 | REMOVED FROM COMM BOARD, ROUTED TO | | | ZONING BOX (SENT EMAIL TO MM) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-13 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-13 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | TAKEN FROM "BOB". BACK TO "COMM" BD #36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-17 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-28 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | TO "BOB" BD#8/TAKEN FROM "COMM" BD#30 | | 2005-07-01 00:00:00 | TO "COMM" BD#30 | | 2005-06-28 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-22 |
Time |
09:46 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-02-22 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2007-02-22 09:59:56 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. | | | SEE MECHANICAL REVIEW NOTES FROM 07/25/2005. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2006-02-06 |
Time |
19:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2006-02-06 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2006-02-06 00:00:00 | SAME AS BEFORE.NEED SEPARATE PLANS AND | | | APPLICATIONS FOR EACH OF THE FOLLOWING: | | | A/C, WALK-IN COOLER, KITCHEN HOOD, HOOD | | | SUPPRESSION SYSTEM. | | | | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-07-25 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-07-25 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2005-07-25 00:00:00 | 1) PLEASE HAVE MECHANICAL CONTRACTOR | | | SUBMIT PLANS AT TIME OF APPLICATION. | | | 2) ADDITIONAL PERMITS REQUIRED FOR WALK | | | IN COLLER & FREEZER,KITCHEN HOOD ANR | | | HOOD SUPPRESSION. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-09 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-09 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2007-07-09 18:32:27 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEWS: THE COMMENT NUMBER SHALL REMAIN | | | THE SAME TO AVOID CONFUSION. | | | ******FROM PREVIOUS REVIEWS: | | | | | | 1. ADDRESSED | | | 2. OK | | | | | | 3. CONTACT DEPT OF BUSINESS REGULATION HOTEL & | | | RESTAURANT DIVISION. PROVIDE THEIR COMMENT SHEET AND | | | TWO SETS OF STAMPED PLANS. NO COMMENT, WORK SHEETSNOT | | | INCLUDED. | | | ****RESONSE NOTED, BUT ONE STAMPED SHEET FROM DBPR WITH | | | THE TWO PAGE "WORKSHEETS" ATTACHED SHALL BE SUBMITTED | | | IN EACH SET OF PLANS. SECTION 101.4.7.-ONLY ONE | | | STAMPED SHEET HAS BEEN SUBMITTED, AND THAT IS ON AN OLD | | | SET OF PLANS THAT WILL NOT BE APPROVED. PLEASE COMPLY | | | WITH REQUIRED STAMPED PAGES AND "WORKSHEETS". | | | ******RESPONSE NOTED, BUT THE DBPR FOOD SERVICE STAMP | | | IS NOT ON THE MOST RECENT SET OF PLAN AS WELL AS THE | | | "WORKSHEETS" AS REQUESTED. | | | | | | 4. ADDRESSED | | | | | | 5. PROVIDE A WATER RISER ISOMETRIC SHOWING ALL FIXTURE | | | CONNECTIONS. BACKFLOW PREVENTER REQUIRED AT WATER | | | METER. | | | ****RESPONSE NOTED, BUT THE WATER ISOMETRIC DOES NOT | | | REFLECT THE FLOOR PLAN. RISER INDICATES A BACKFLOW | | | PREVENTER AND ALSO A BACKFLOW. PLEASE CLARIFY. -THE | | | RISER SHOWS 3 W/C'S & 4 LAVS, WHEREAS THE FLOOR PLAN | | | ONLY SHOWS TWO W/C'S AND TWO LAV'S.-THE MOP SINK IS | | | NOT INDICATED ON THE RISER.-THE W/C & LAV IN THE | | | SECOND TOILET ROOM ARE NOT SHOWN IN THE SAME ORDER ON | | | THE RISER DIAGRAM AS SHOWN ON THE PLUMBING PLAN, (FLOOR | | | PLAN).-PLEASE IDENTIFY ALL FIXTURES ON THE WATER | | | RISER ISOMETRIC DIAGRAM. SECTION 104.2.1. | | | ******RESPONSE NOTED, BUT THE RISER DIAGRAM STILL DOES | | | NOT REFLECT THE FLOOR PLAN. THE LAVS AND W/CS ARE BACK | | | TO BACK IN SEPARATE TOILET ROOMS, NOT LINED UP ON ONE | | | COMMON WALL. ALSO AS DRAWN, THE WATER SUPPLY IS | | | INSTALLED UNDERGROUND AND THE WATER STUBBED UP THROUGH | | | THE FLOOR. THIS WORKS EXCEPT FOR THEWATER HEATER | | | WHICH IS IN A LOFT ABOVE THE COOLER/FREEZER. AS DRAWN | | | THE WATER HEATER WOULD BE BELOW GROUND. A RISER TO THE | | | LOFT FOR THE WATER HEATER IS REQUIRED TO REFLECT THE | | | FLOOR PLAN. | | | | | | 6. NEW COMMENT PLUMBING ISOMETRIC DOES NOT MATCH THE | | | FLOOR PLAN.. | | | ****RESPONSE NOTED, BUT THE SANITARY RISER ISOMETRIC | | | DIAGRAM STILL DOES NOT REFLECT THE FLOOR PLAN. THE | | | FLOOR SINK FOR THE ICE MAKER IS SHOWN CONNECTING TO THE | | | GREASE SYSTEM ON THE FLOOR PLAN, BUT IS SHOWN ON THE | | | SANITARY SYSTEM ON THE RISER DIAGRAM.-THREE FLOOR | | | DRAINS AND ONE HAND SINK ARE ON A SEPARATE BRANCH LINE | | | ON THE FLOOR PLAN, BUT ARE ON THE SAME BRANCH LINE WITH | | | THE THREE COMPARTMENT SINK ON THE RISER DIAGRAM.- THE | | | MOP SINK IS SHOWN BY THE THREE COMPARTMENT SINK ON THE | | | RISER DIAGRAM, BUT SHOWN BY THE TOILET ROOMS ON THE | | | FLOOR PLAN.-IDENTIFY ALL FIXTURES ON THE RISER | | | DIAGRAM AND CORRELATE ALL INFORMATION BETWEEN THE FLOOR | | | PLAN AND THE RISER DIAGRAM.-SHOW ALL PIPE SIZES.- | | | (SEE ATTACHED SHEET FOR AN EXAMPLE OF A RISER DIAGRAM | | | THAT REFLECTS THE FLOOR PLAN AND MEETS CODE | | | REQUIREMENTS). | | | ******RESPONSE NOTED, BUT THE RISER DIAGRAM STILL DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT MEET CODE | | | REQUIREMENTS. THE RISER DIAGRAM SHOWS 2 EXTRA LAVS NOT | | | SHOWN ON THE FLOOR PLAN.--THE BRANCH LINES | | | INDICATED ON THE FLOOR PLAN ARE NOT REFLECTED ON THE | | | RISER DIAGRAM AS INDICATED PREVIOUSLY. --THERE ARE | | | TWO DRAIN LINES CONNECTING TO THE FLOOR SINK IN THE | | | WAITRESS STATION.--THE MOP SINK SHALL BE VENTED. | | | SECTIONS 106.1.1, 1002.1. THE RISER DIAGRAM SENT AS AN | | | EXAMPLE WAS NOT REFERENCED WHEN REDRAWING THE SANT. | | | RISER DIAGRAM. | | | | | | 7. SHT 2, NOTES FROM PREVIOUS PLAN REVIEWER, JOHN LEECH | | | DENIED | | | | | | NEW COMMENTS: | | | | | | 1.OK | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | | | | ************NEW COMMENTS************ | | | | | | 1C. SHT P-1 SUBMIT CALCULATIONS FOR THE WATER PIPE | | | SIZING PER SECTION 604.3. | | | ******RESPONSE NOTED, BUT NO CALCULATIONS WERE FOUND ON | | | SHT P-1. | | | | | | 2C. OK | | | | | | 3C. SHT P-1 THE FLOOR DRAIN LOCATED WITHIN THE WALK IN | | | COOLER SHALL BE INDIRECTLY CONNECTED TO THE SANITARY | | | SYSTEM BY AN AIR GAP. SECTION 802.1.2. | | | ******RESPONSE NOTED, BUT IT STILL APPEARS TO BE | | | CONNECTED DIRECTLY TO THE FLOOR SINK. PLEASE SUBMIT A | | | DETAIL SHOWING THE INDIRECT WAST CONNECTION TO THE | | | FLOOR SINK AS WELL AS THE REQUIRED 4" AIR GAP. | | | | | | 4C. SEE ATTACHED SHEET CONCERNING THE DESIGN | | | PROFESSIONAL AND FLORIDA STATUTE 553.80(2)(B). THIS IS | | | GIVEN AS A ONE TIME NOTICE. | | | ******A FOUR TIMES THE FEE WOULD HAVE BEEN ASSESSED | | | THIS TIME, BUT THE ELECTRICAL PLAN REVIEWER HAS | | | ASSESSED THE FEE. IF THE PLANS ARE SUBMITTED AGAIN AND | | | THE SAME COMMENTS ARE STILL NOT ADDRESSED, THEN ANOTHER | | | FOUR TIMES THE FEE WILL BE ASSESSED. | | | | | | ************NEW COMMENT************ | | | | | | 1D. THERMAL EXPANSION CONTROL IS REQUIRED PER SECTION | | | 607.3.2. INDICATE THE METHOD OF COMPLIANCE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-28 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-27 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2007-02-28 09:09:05 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEWS: THE COMMENT NUMBER SHALL REMAIN | | | THE SAME TO AVOID CONFUSION. | | | | | | 1. ADDRESSED | | | 2. OK | | | | | | 3. CONTACT DEPT OF BUSINESS REGULATION HOTEL & | | | RESTAURANT DIVISION. PROVIDE THEIR COMMENT SHEET AND | | | TWO SETS OF STAMPED PLANS. NO COMMENT, WORK SHEETSNOT | | | INCLUDED. | | | ****RESONSE NOTED, BUT ONE STAMPED SHEET FROM DBPR WITH | | | THE TWO PAGE "WORKSHEETS" ATTACHED SHALL BE SUBMITTED | | | IN EACH SET OF PLANS. SECTION 101.4.7.-ONLY ONE | | | STAMPED SHEET HAS BEEN SUBMITTED, AND THAT IS ON AN OLD | | | SET OF PLANS THAT WILL NOT BE APPROVED. PLEASE COMPLY | | | WITH REQUIRED STAMPED PAGES AND "WORKSHEETS". | | | | | | 4. ADDRESSED | | | | | | 5. PROVIDE A WATER RISER ISOMETRIC SHOWING ALL FIXTURE | | | CONNECTIONS. BACKFLOW PREVENTER REQUIRED AT WATER | | | METER. | | | ****RESPONSE NOTED, BUT THE WATER ISOMETRIC DOES NOT | | | REFLECT THE FLOOR PLAN. RISER INDICATES A BACKFLOW | | | PREVENTER AND ALSO A BACKFLOW. PLEASE CLARIFY. -THE | | | RISER SHOWS 3 W/C'S & 4 LAVS, WHEREAS THE FLOOR PLAN | | | ONLY SHOWS TWO W/C'S AND TWO LAV'S.-THE MOP SINK IS | | | NOT INDICATED ON THE RISER.-THE W/C & LAV IN THE | | | SECOND TOILET ROOM ARE NOT SHOWN IN THE SAME ORDER ON | | | THE RISER DIAGRAM AS SHOWN ON THE PLUMBING PLAN, (FLOOR | | | PLAN).-PLEASE IDENTIFY ALL FIXTURES ON THE WATER | | | RISER ISOMETRIC DIAGRAM. SECTION 104.2.1. | | | | | | 6. NEW COMMENT PLUMBING ISOMETRIC DOES NOT MATCH THE | | | FLOOR PLAN.. | | | ****RESPONSE NOTED, BUT THE SANITARY RISER ISOMETRIC | | | DIAGRAM STILL DOES NOT REFLECT THE FLOOR PLAN. THE | | | FLOOR SINK FOR THE ICE MAKER IS SHOWN CONNECTING TO THE | | | GREASE SYSTEM ON THE FLOOR PLAN, BUT IS SHOWN ON THE | | | SANITARY SYSTEM ON THE RISER DIAGRAM.-THREE FLOOR | | | DRAINS AND ONE HAND SINK ARE ON A SEPARATE BRANCH LINE | | | ON THE FLOOR PLAN, BUT ARE ON THE SAME BRANCH LINE WITH | | | THE THREE COMPARTMENT SINK ON THE RISER DIAGRAM.- THE | | | MOP SINK IS SHOWN BY THE THREE COMPARTMENT SINK ON THE | | | RISER DIAGRAM, BUT SHOWN BY THE TOILET ROOMS ON THE | | | FLOOR PLAN.-IDENTIFY ALL FIXTURES ON THE RISER | | | DIAGRAM AND CORRELATE ALL INFORMATION BETWEEN THE FLOOR | | | PLAN AND THE RISER DIAGRAM.-SHOW ALL PIPE SIZES.- | | | (SEE ATTACHED SHEET FOR AN EXAMPLE OF A RISER DIAGRAM | | | THAT REFLECTS THE FLOOR PLAN AND MEETS CODE | | | REQUIREMENTS). | | | | | | 7. SHT 2, NOTES FROM PREVIOUS PLAN REVIEWER, JOHN LEECH | | | DENIED | | | | | | NEW COMMENTS: | | | | | | 1. SHOW THE LOCATION OF THE WATER HEATER. IF THE WATER | | | HEATER IS OUTSIDE, IT MUST BE PROTECTED FROM THE | | | WEATHER OR BE APPROVED BY THE MANUFACTURE FOR OUTSIDE | | | INSTALLATION. | | | ****RESPONSE NOTED, BUT THE WATER HEATER IS NOT SHOWN | | | ON THE FLOOR PLAN/PLUMBING PLAN. | | | | | | 2. OK | | | 3. OK | | | | | | 4. FLOOR SINK REQUIRED AT WAITRESS STATION FOR INDIRECT | | | WASTED. | | | ****RESPONSE NOTED, BUT THE SINK IS STILL SHOWN | | | DIRECTLY CONNECTED TO THE WASTE SYSTEM. SECTIONS 802.1 | | | & 802.1.1 | | | | | | 5. OK | | | | | | ************NEW COMMENTS************ | | | | | | 1C. SHT P-1 SUBMIT CALCULATIONS FOR THE WATER PIPE | | | SIZING PER SECTION 604.3. | | | | | | 2C. SHT P-1 THE PLUMBING PLAN SHOWS 3" FLOOR DRAINS | | | CONNECTING TO 2" BRANCH LINES. PIPE CAN NOT BE REDUCED | | | IN SIZE IN THE DIRECTION OF FLOW. SECTION 704.2. | | | | | | 3C. SHT P-1 THE FLOOR DRAIN LOCATED WITHIN THE WALK IN | | | COOLER SHALL BE INDIRECTLY CONNECTED TO THE SANITARY | | | SYSTEM BY AN AIR GAP. SECTION 802.1.2. | | | | | | 4C. SEE ATTACHED SHEET CONCERNING THE DESIGN | | | PROFESSIONAL AND FLORIDA STATUTE 553.80(2)(B). THIS IS | | | GIVEN AS A ONE TIME NOTICE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-10-28 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-10-28 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-10-28 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2006-10-28 07:39:46 | PAUL SCHMITZ, PLUMBING & GAS PLANS | | | EXAMINER561-805-6692 | | | | | | [email protected] | | | PLUMBING GAS PLAN REVIEW FBC 2001 | | | | | | DENIED | | | | | | WHEN RESUBMITTING. | | | PLEASE INCLUDE A RESPONCE LETTER INDICATING HOW THE | | | ITEMS WERE ADDRESSED, THIS WILL HELP TO EXPIDITE THE | | | PLAN REVIEW. | | | | | | | | | | | | (1)ADRESSED | | | | | | (2) CONTACT MS LYNN MASSON, WEST PALM | | | BEACH ENVIROMENTAL COMPLIANCE | | | FOR GREASE TRAP SIZING REQUIRMENTS. | | | LOCAL ORDANCE. PHONE 561-822-2271 | | | NEW COMMENT, GREASE TRAP SIZE ON PLANS INCORRECT | | | | | | (3) CONTACT DEPT OF BUSINESS REGULATION | | | HOTEL & RESTURANT DIVISION | | | PROVIDE THEIR COMMENT SHEET AND TWO SETS | | | OF STAMPED PLANS. | | | NEW COMMENT,WORK SHEETS NOT INCLUDED. | | | | | | (4) ADDRESSED | | | | | | (5)PROVIDE A WATER RISER ISOMETRIC SHOWING | | | ALL FIXTURE CONNECTIONS.BACK FLOW PREVENTER REQUIRED | | | AT WATER METER. | | | | | | (6) NEW COMMENT PLUMBING ISOMETRIC DOES NOT MATCH FLOOR | | | PLAN. | | | | | | (7) SHT 2, | | | NOTES FROM PREVOIOUS PLAN REVIEWER, JOHN LEECH DENIED | | | | | | NEW COMMENTS; | | | 1.SHOW LOCATION OF WATER HEATER. IF WATER HEATER IS OUT | | | SIDE IT MUST BE PROTECTED FROM THE WEATHER OR BE | | | APPROVED BY THE MANUFATURE FOR OUT SIDE INSTALLATION. | | | | | | 2.MOP SINK MUST GO TO GREASY WASTE. | | | | | | 3.DISHWASHER MUST DISCHARGE INDIRECTLY TO , (FLOOR SINK | | | ) | | | | | | 4.FLOOR SINK REQUIRED AT WAITRESS STATION FOR INDIRECT | | | WASTE. | | | | | | 5.THREE COMPARTMENT SINK SHOUD DISCHARGE TO A FLOOR | | | SINK, SINK COULD BE USED FOR FOOD PREP. SEE PLUMBING | | | CODE SEC. 802.1.1. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-10 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-10 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2006-03-10 00:00:00 | DENIED; | | | ITEMS NOT COVERED FROM FIRST REVIEW; | | | COMMENT #2 CONTACT MS LYNN MASSON, WEST | | | PALM BEACH ENVIROMENT COMPLIANCE FOR | | | GREASE TRAP SIZING REQUIRMENTS. LOCAL | | | ORDANCE. PHONE (561) 822-2271. | | | COMMENT # 3 HOTEL AND RESTURANT DIVISION | | | WORK SHEETS WERE NOT ATACHED TO PLANS. | | | COMMENT # 4 DISHWASHER TO DRAIN TO | | | SANITARY SEWER (NOT SHOWN ON RISER | | | DIAGRAM. WATER RISER DIAGRAM NOT SHOWN. | | | BACKFLOW NOT SHOWN ON PLANS. | | | COMMENT # 5 GAS REQUIREMENTS, TYPE OF | | | GAS NATURAL OR L.P., LIST TOTAL BTU'S | | | AND LONGEST RUN. END OF COMMENTS FROM | | | FIRST REVIEW. | | | NEW COMMENTS; | | | 1.SHOW LOCATION OF WATER HEATER. IF | | | WATER HEATER IS OUT SIDE IT MUST BE | | | PROTECTED FROM THE WEATHER OR BE | | | APPROVED BY THE MANUFATURE FOR OUT SIDE | | | INSTALLATION. | | | 2.MOP SINK MUST GO TO GREASY WASTE. | | | 3.DISHWASHER MUST DISCHARGE INDIRECTLY | | | TO SANITARY, (FLOOR SINK REQUIRED) | | | 4.FLOOR SINK REQUIRED AT WAITRESS | | | STATION FOR INDIRECT WASTE. | | | 5.THREE COMPARTMENT SINK SHOUD DISCHARGE | | | TO A FLOOR SINK, SINK COULD BE USED FOR | | | FOOD PREP. SEE PLUMBING CODE SEC. | | | 802.1.1. | | | 6.GAS SYSTEM IS REQUIRED TO HAVE A | | | EMERGENCY SHUT OFF VALVE FOR COOKING | | | EQUIPMENT. A SHUTOFF VALVE IS REQUIRED | | | UP STREAM STREAM OF THE EMERGENCY VALVE | | | AND A UNION DOWN STREAM SO VALVE CAN BE | | | REPLACED OR REPAIRED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-30 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-07-30 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-07-30 |
Time |
13:15 |
Sent To |
Z |
|
| Notes |
| 2005-07-30 00:00:00 | PAUL SCHMITZ, PLUMBING & GAS PLANS | | | EXAMINER561-805-6692 | | | | | | [email protected] | | | PLUMBING GAS PLAN REVIEW FBC 2001 | | | DENIED | | | (1) ?3401.2.2 CHANGE OF OCCUPANCY | | | ?3401.2.2.1 IF THE OCCUPANCY | | | CLASSIFICATION OR OCCUPANCY | | | SUBCLASSIFICATIONS OF ANY EXISTING | | | BUILDING OR STRUCTURE IS CHANGED, THE | | | BUILDING, ELECTRICAL, GAS, | | | MECHANICAL AND PLUMBING SYSTEMS SHALL BE | | | MADE TO CONFORM TO THE INTENT OF THE | | | TECHNICAL CODES AS REQUIRED BY THE | | | BUILDING OFFICIAL. | | | ?3401.2.2.2 CHANGES IN THE OCCUPANCY | | | OF A BUILDING NOW EXISTING OR | | | HEREAFTER ERECTED SHALL NOT BE MADE | | | UNTIL A REVISED CERTIFICATE OF | | | OCCUPANCY HAS BEEN ISSUED BY THE | | | BUILDING OFFICIAL CERTIFYING THAT THE | | | FLOORS ARE SUITABLE FOR THE LOADS CHARACTERISTIC OF | | | THE PROPOSED | | | OCCUPANCY.SEE ?106. | | | (2) CONTACT MS LYNN MASSON, WEST PALM | | | BEACH ENVIROMENTAL COMPLIANCE | | | FOR GREASE TRAP SIZING REQUIRMENTS. | | | LOCAL ORDANCE. PHONE 561-822-2271 | | | (3) CONTACT DEPT OF BUSINESS REGULATION | | | HOTEL & RESTURANT DIVISION | | | PROVIDE THEIR COMMENT SHEET AND TWO SETS | | | OF STAMPED PLANS. | | | (4) ?P403.2 SEPARATE FACILITIES. WHERE | | | PLUMBING FIXTURES ARE REQUIRED, | | | SEPARATE FACILITIES SHALL BE PROVIDED | | | FOR EACH SEX. | | | EXCEPTIONS: | | | 2. SEPARATE EMPLOYEE FACILITIES SHALL | | | NOT BE REQUIRED IN OCCUPANCIES IN | | | WHICH 15 OR LESS PEOPLE ARE | | | EMPLOYED. | | | 3. SEPARATE FACILITIES SHALL NOT BE | | | REQUIRED FOR FOOD SERVICE | | | ESTABLISHMENTS WHICH SEAT 10 | | | PERSONS OR LESS. | | | ?P403.3 NUMBER OF OCCUPANTS OF EACH SEX. | | | THE REQUIRED WATER CLOSETS, | | | LAVATORIES, AND SHOWERS OR BATHTUBS | | | SHALL BE DISTRIBUTED EQUALLY BETWEEN | | | THE SEXES BASED ON THE PERCENTAGE OF | | | EACH SEX ANTICIPATED IN THE OCCUPANT | | | LOAD.THE OCCUPANT LOAD SHALL BE | | | COMPOSED OF 50 PERCENT OF EACH SEX, | | | UNLESS STATISTICAL DATA APPROVED BY THE | | | CODE OFFICIAL INDICATE A DIFFERENT | | | DISTRIBUTION OF THE SEXES.(SEE ALSO | | | ?P403.1.1) | | | (4) SHT A1.1 PLUMBING ISOMETRIC.DENIED | | | KITCHEN AREA EQUIPMENT DRAIN TO GREASE | | | WASTE SYSTEM. | | | DISH WASHER DRAIN TO SANITARY SEWER. | | | REST ROOM WASTE TO SANITARY SEWER. | | | PROVIDE A WATER RISER ISOMETRIC SHOWING | | | ALL FIXTURE CONNECTIONS. | | | BACK FLOW PREVENTER REQUIRED AT METER. | | | (5) PROVIDE A GAS PIPING ISOMETRIC | | | SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | TYPE OF GAS, (LP OR NATURAL) | | | BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2001 FUEL GAS CODE SECS. 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU | | | 402(34). | | | SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | | | | END OF COMMENTS | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-06-08 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-06-07 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2007-06-08 16:16:58 | PLANNING AND ZONING | | | | | | ***FAILED*** | | | | | | FROM PREVIOUS REVIEW: | | | | | | 1. PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2. PLEASE PROVIDE A SURVEY OF THE PROPERTY.THE SURVEY | | | SHALL BE LESS THAN A YEAR OLD. | | | | | | 3. DUMPSTER ENCLOSURE DETAIL DOES NOT MEET ZONING | | | REGULATIONS.PLEASE REFER TO SECTION 94-444(B) FOR | | | OUTDOOR STORAGE REGULATIONS. | | | | | | NEW COMMENTS: | | | | | | 4. PROVIDE A LETTER AND PLANS STAMPED APPROVED FROM THE | | | ENGINEERING SERVICES DEPARTMENT APPROVING THE SIZE AND | | | LOCATION OF THE DUMPSTER ENCLOSURE. | | | | | | 5. PER THE FINAL ORDER DATED FEBRUARY 3, 2005, GRANTING | | | THE CLASS B SPECIAL USE PERMIT TO OPERATE A RESTAURANT | | | IN AN EXISTING COMMERCIAL BUILDING, THE FOLLOWING SHALL | | | BE PROVIDED | | | A. A COPY OF THE RECORDED UNITY OF TITLE OF ALL LOTS | | | ASSOCIATED WITH THE SUBJECT PROPERTY | | | (74-43-43-16-17-001-0131, 74-43-43-16-17-001-0132, AND | | | 74-43-43-16-17-001-0150). | | | B. A COPY OF THE SITE PLAN APPROVAL LETTER.IN THE | | | EVENT THAT A SITE PLAN REVIEW HAS NOT BEEN APPROVED, | | | THE PROJECT SHALL FOLLOW THE INFORMAL SITE PLAN REVIEW | | | PROCESS. | | | | | | 6. FROM THE FINAL ORDER DATED FEBRUARY 3, 2005: | | | | | | ??THERE WAS A MOTION FOR APPROVAL TO GRANT THE CLASS B | | | SPECIAL USE PERMIT, TO OPERATE A RESTAURANT IN AN | | | EXISTING COMMERCIAL BUILDING IS HEREBY GRANTED, WITH | | | THE FOLLOWING CONDITIONS: | | | | | | A. APPLICANT MUST APPLY FOR AN INFORMAL SITE PLAN | | | REVIEW; | | | B. UNITY OF TITLE MUST BE FILED AND RECORDED WITH PALM | | | BEACH COUNTY TO JOIN ALL LOTS ASSOCIATED WITH THE | | | SUBJECT PROPERTY; | | | C. RESTAURANT MAY NOT EXPAND IN NET INTERIOR AREA?? | | | | | | 7. A COPY OF THE FINAL ORDER MAY BE OBTAINED FROM THE | | | PLANNING AND ZONING DEPARTMENT. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-02-12 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-02-12 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2007-02-12 12:32:15 | PLANNING AND ZONING | | | | | | ***FAILED*** | | | | | | 1) PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2) PLEASE PROVIDE A SURVEY OF THE PROPERTY.THE SURVEY | | | SHALL BE LESS THAN A YEAR OLD. | | | | | | 3) DUMPSTER ENCLOSURE DETAIL DOES NOT MEET ZONING | | | REGULATIONS.PLEASE REFER TO SECTION 94-444(B) FOR | | | OUTDOOR STORAGE REGULATIONS. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA AT (561) | | | 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2006-11-09 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2006-11-09 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2006-11-09 09:10:02 | 11/09/2006 PLANNING AND ZONING ***FAILED*** | | | | | | 1) PLEASE NOTE THAT THE PROPERTY HAS ALREADY | | | INSUFFICIENT PARKING SPACES FOR THE CURRENT USES. THUS, | | | THE PROPOSED DUMPSTER CAN NOT BE PLACED ON A PARKING | | | SPACE AS IT WILL REDUCE THE NUMBER OF EXISTING PARKING | | | SPACES AND INCREASE ITS NONCONFORMITY. | | | | | | 2) DUMPSTER WITH ENCLOSURE SHALL BE RELOCATED ON THE | | | SITE. | | | A) PLEASE CONTACT PUBLIC UTILITIES FOR ALTERNATIVE | | | LOCATIONS.A SIGN-OFF FROM PUBLIC UTILITIES SHALL BE | | | REQUIRED ONCE A LOCATION HAS BEEN DETERMINED. | | | | | | 3) PLEASE PROVIDE DUMPSTER ENCLOSURE DETAILS MEETING | | | SECTION 94-444(B) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA AT (561) | | | 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-06 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-06 |
Time |
17:00 |
Sent To |
I |
|
| Notes |
| 2006-04-06 00:00:00 | RE-STAMP PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-17 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-17 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2005-08-17 00:00:00 | NOTE: PARKING LOT MUST BE DOUBLED | | | STRIPPED/REPAIR EXISTING FENCE. SHIRLEY | | | GRAHAM, ASSOCIATE PLANNER 822-1435 MM |
|
|
|
Account Summary | Usage Policy | Privacy Policy