Plan Review Details - Permit 05061664
Plan Review Stops For Permit 05061664
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2007-03-28 Cont ID  
Sent By lmartine Date 2007-03-28 Time 11:20 Rev Time 0.00
Received By lmartine Date 2007-03-28 Time 11:20 Sent To  
Notes
2007-03-28 11:23:23 
  
 SITE WALL REQUIRES SEPERATE PERMIT.
  
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-11-20 Cont ID  
Sent By alange Date 2006-11-20 Time 13:29 Rev Time 0.00
Received By alange Date 2006-11-20 Time 13:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-05-17 Cont ID  
Sent By alange Date 2006-05-17 Time 11:39 Rev Time 0.75
Received By alange Date 2006-05-17 Time 11:39 Sent To  
Notes
2006-05-17 00:00:00STRUCTURAL REV OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-05-16 Cont ID  
Sent By alange Date 2006-05-16 Time 08:49 Rev Time 2.00
Received By alange Date 2006-05-16 Time 08:49 Sent To  
Notes
2006-05-16 00:00:00ADDED NEW ROOM ADDITION TO EXISTING PLAN
 OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-02-06 Cont ID  
Sent By alange Date 2006-02-06 Time 11:10 Rev Time 2.00
Received By alange Date 2006-02-06 Time 08:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-12-09 Cont ID  
Sent By alange Date 2005-12-09 Time 14:45 Rev Time 2.50
Received By alange Date 2005-12-09 Time 09:20 Sent To  
Notes
2005-12-09 00:00:00DENIED
  
 4. PROPERTY IS IN FLOOD ZONE "A" .
 A.SHOW ON PLANS HOW COTTAGE AND ROOM
 ADDITION WILL BE 6" ABOVE THE BASE
 ELEVATION OF 7FT.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-01 Cont ID  
Sent By alange Date 2005-08-01 Time 08:59 Rev Time 3.50
Received By alange Date 2005-08-01 Time 08:59 Sent To  
Notes
2005-08-01 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.PROPERTY IS IN AN AREA OF
 QUESTIONABLE SOILS. SUBMIT TWO ORIGONALS
 OF A SOILS REPORT.
  
 4. PROPERTY IS IN FLOOD ZONE "A" SUBMIT
 AN ELEVATION CERTIFICATE.
 A.SHOW ON PLANS HOW COTTAGE WILL BE 6"
 ABOVE THE BASE ELEVATION OF 7FT.
  
 B.ALL NEW CONSTRUCTION OR SUBSTANTIAL
 IMPROVMENT OF ANY EXISTING RESIDENTIAL
 STRUCTURE SHALL HAVE THE LOWEST FLOOR
 ELEVATED TO SIX INCHES ABOVE THE BASE
 FLOOD ELEVATION. WPB MUNI-CODE 94-546
 (B) (1)
 SHOW FINISH FLOOR HEIGHT OF EXISTING
 BUILDING AND ROOM ADDITION.
  
 5.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS COMPLYING WITH FBC 2309.6
  
 6. SHOW METHOD OF ATTIC VENTILATION.
 FBC 2309.7.1
  
 7.SUBMIT A GUARD RAIL DETAIL SHOWING
 COMPLIANCE WITH FBC CHAPTER 10
  
 8.BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUATION HAS BEEN
 REVISED TO $329,328.00 ADDITIONAL PERMIT
 FEES ARE DUE.
  
 9.SQUARE FOOTAGE ON APPLICATION HAS
 BEEN REVISED.
  
 10. PRODUCT APPROVALS WITH QUALITY
 ASSURANCE REQUIRED FOR THE FOLLOWING
 ITEMS:ROOFING, EXTERIOR DOORS AND
 WINDOWS, IMPACT PROTECTION, HARDIE
 SIDING, AND STRAPS AND TIE-DOWNS.
 ALL PRODUCT APPROVALS SUBMITTED SHALL
 HAVE THE FOLLOWING STATE PRODUCT
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2007-04-02 Cont ID  
Sent By btrobaug Date 2007-04-02 Time 13:32 Rev Time 0.50
Received By btrobaug Date 2007-04-02 Time 12:40 Sent To M
Notes
2007-04-02 13:33:17REV # 7INDICATED LOW VOLTAGE SYSTEM, FOR FINAL./WRT.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-03-20 Cont ID  
Sent By btrobaug Date 2007-03-20 Time 07:23 Rev Time 0.50
Received By btrobaug Date 2007-03-20 Time 06:41 Sent To M
Notes
2007-03-20 07:20:31 
  
 SHEET MEP-2 SUBMITTED 3/15/07, SAME SHEET REVISION THAT
 WAS SUBMITTED ON 3/9/07?
  
 WRT.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-03-16 Cont ID  
Sent By btrobaug Date 2007-03-16 Time 14:04 Rev Time 1.00
Received By btrobaug Date 2007-03-16 Time 13:22 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-05-12 Cont ID  
Sent By btrobaug Date 2006-05-12 Time 07:41 Rev Time 0.75
Received By btrobaug Date 2006-05-12 Time 06:31 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-01-24 Cont ID  
Sent By btrobaug Date 2006-01-24 Time 16:52 Rev Time 0.75
Received By btrobaug Date 2006-01-24 Time 13:37 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-12-06 Cont ID  
Sent By btrobaug Date 2005-12-06 Time 11:23 Rev Time 2.00
Received By btrobaug Date 2005-12-06 Time 06:19 Sent To P
Notes
2005-12-06 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} CAN'T FIND MANUFACTURERS
 SPECIFICATIONS FOR THE GENERATOR AND
 ATS.
  
 2} THE LOAD CALC SHOWN FOR PANEL "SB"(79
 AMPS) EXCEEDS THE SHOWN GENERATOR OUTPUT
 OF 59 AMPS. PLEASE CLARIFY.
  
 3} PLEASE CONFIRM THAT FPL IS PROVIDING
 GRC FOR THE SERVICE. TYPICALLY THIS
 WOULD BE PVC. ALSO 2-4/0 CONDUCTORS WILL
 NOT BE RUN WITH THE CABLE. THIS SECTION
 OF THE RISER MAY BE LEFT BLANK IF
 SUPPLIED BY FPL. THE DESIGNER ONLY NEEDS
 TO INDICATE THE SIZE OF THE MAIN BREAKER
 AND THE SERVICE CONDUCTORS FROM THAT
 POINT.
  
 4} THE 250 MCM CONDUCTORS FROM 400 AMP
 MAIN ARE IN VIOLATION OF 310.15(B)(6),
 THEY MUST BE A MINIMUM OF 500 MCM.
  
 5} THE TWO 4/0 "GROUNDS" SHOWN FROM THE
 METER/MAIN TO THE GUTTER ARE INCORRECT.
 ONE CONDUCTOR WOULD BE A NEUTRAL, AND
 THE OTHER A GROUND. THEY WOULD NOT BE
 THE SAME SIZE. SEE 250.122 FOR EQUIPMENT
 GROUND AND 310-15 FOR THE NEUTRAL SIZE.
  
 6} SHEET E.1 INDICATES PANELS "C,H,AND
 SB". SHEET E-2 RISER HAS DIFFERENT
 DESIGNATIONS, PLEASE CORRELATE.
  
 7} PANEL "H" IS SHOWN AS MLO (SCHEDULE).
 MUST HAVE THE MAIN INDICATED ON
 METER/MAIN.
  
 8} THE FEED FROM THE GUTTER TO THE 125
 AMP DISCONNECT MARKED (CH) DOES NOT HAVE
 A NEUTRAL. THE OTHER TWO DISCONNECTS DO
 NOT HAVE A GROUND.
  
 9} THE PANELS INTHE LAUNDRY ROOM DO NOT
 HAVE THE CLEARANCE REQUIREMENTS OF
 110.26.
  
 10} SEE 250.32(B)(1) FOR EQUIPMENT
 GROUND REQUIREMENT TO SEPERATE
 STRUCTURES. THE FEED TO THE CARRIAGE
 HOUSE MUST COMPLY.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-07-21 Cont ID  
Sent By btrobaug Date 2005-07-21 Time 10:11 Rev Time 2.00
Received By btrobaug Date 2005-07-21 Time 07:03 Sent To M
Notes
2005-07-21 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE MANUFACTURERS
 SPECIFICATIONS FOR THE GENERATOR AND
 TRANSFER SWITCH SHOWN ON THE RISER
 DIAGRAM.
  
 2} INDICATE THE SERVICE CONDUCTOR AND
 CONDUIT SIZE(S) FROM THE METER TO THE
 GUTTER. 215.5.
  
 3} INDICATE TAP CONDUCTOR AND CONDUIT
 SIZES FROM THE GUTTER TO THE DISCONNECTS
  
 ON THE RISER. 215.5.
  
 4} PLEASE SHOW A SITE PLAN LOCATING ALL
 SERVICE AND STANDBY EQUIPMENT. PLEASE
 NOTE IF THE 125 AMP PANEL ON THE RISER
 IS LOCATED AT OR ON THE CARRIAGE HOUSE
 IT MUST CONTAIN A MAIN BREAKER. A
 DISCONNECT MUST BE SUPPLIED PER 225.31.
 ALSO SEE 250.30 FOR GROUNDING
 REQUIREMENTS, NOT INDICATED ON THE
 RISER.
  
 5} PLEASE GIVE A LOAD CALCULATION FOR
 THE STANDBY PANEL. SEE 702.5, ALL
 CIRCUITS HAVE LOADS, 5 ARE LISTED WITH
 NO LOADS ON THE SCHEDULE.
  
 6} THE 3/0 CONDUCTORS RUN FROM THE 400
 AMP DISCONNECT TO THE 400 AMP PANEL DO
 NOT COMPLY WITH 310.16 AMPERAGE
 REQUIREMENTS.
  
 7} THE LAUNDRY CIRCUIT MUST COMPLY WITH
 210.11(C)(2). 20 AMP #12 BC.
  
 8) PLEASE SEE THE CONDUCTOR AND OCP SIZE
  
 FOR THE AHU AND A/C UNIT #1 ARE
 INCORRECT. 310.16. PLEASE VERIFY THE
 NAMEPLATE AT 17KVA ON AC#1.
  
 7} THERE IS ONLY 1 SMALL APPLIANCE
 CIRCUIT LISTED ON THE PANEL SCHEDULE.
 SEE 210.11(C)(1).
  
 8) THERE ARE 2 WATER HEATERS IN THE
 CALCULATION, ONLY ONE LISTED ON
 SCHEDULES. ALSO SEE THAT ONE LEG IS A
 #10 AND THE OTHER A #12 ON THE ONE
 SHOWN.
  
 9} THE REFER AND SM APP CIRCUITS ON
 SCHED "SB" ARE SHOWN AS 2 POLE, PLEASE
 CORRECT.
  
 10} LIST THE NEW BATH CIRCUITS PER
 210.11(C)(3), INCLUDING CARRIAGE HOUSE,
 IN RESPECTIVE PANELS.
  
 IF THEERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-03-26 Cont ID  
Sent By spalmer Date 2007-03-26 Time 18:28 Rev Time 0.00
Received By spalmer Date 2007-03-26 Time 18:28 Sent To E
Notes
2007-03-29 15:53:43TO BT'S DESK ON 3/29
2007-03-26 18:29:14TO DEWEY PALMER

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-03-12 Cont ID  
Sent By adarroug Date 2007-03-12 Time 09:44 Rev Time 0.00
Received By adarroug Date 2007-03-12 Time 09:44 Sent To E
Notes
2007-03-12 09:45:01TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-11-14 Cont ID  
Sent By adarroug Date 2006-11-14 Time 14:55 Rev Time 0.00
Received By adarroug Date 2006-11-14 Time 14:55 Sent To B
Notes
2006-11-14 14:55:51TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-05-11 Cont ID  
Sent By adarroug Date 2006-05-11 Time 16:06 Rev Time 0.00
Received By adarroug Date 2006-05-11 Time 16:06 Sent To E
Notes
2006-05-11 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-05-11 Cont ID  
Sent By adarroug Date 2006-05-11 Time 13:01 Rev Time 0.00
Received By adarroug Date 2006-05-11 Time 13:01 Sent To B
Notes
2006-05-11 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-04-25 Cont ID  
Sent By adarroug Date 2006-04-25 Time 09:17 Rev Time 0.00
Received By adarroug Date 2006-04-25 Time 09:17 Sent To Z
Notes
2006-04-25 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-04 Cont ID  
Sent By adarroug Date 2006-01-04 Time 15:10 Rev Time 0.00
Received By adarroug Date 2006-01-04 Time 15:10 Sent To Z
Notes
2006-01-04 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-12-05 Cont ID  
Sent By adarroug Date 2005-12-05 Time 10:13 Rev Time 0.00
Received By adarroug Date 2005-12-05 Time 10:13 Sent To E
Notes
2005-12-05 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-18 Cont ID  
Sent By adarroug Date 2005-11-18 Time 09:10 Rev Time 0.00
Received By adarroug Date 2005-11-18 Time 09:10 Sent To Z
Notes
2005-11-18 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 14:17 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 14:17 Sent To E
Notes
2005-07-08 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-01 Cont ID  
Sent By alange Date 2005-08-01 Time 10:19 Rev Time 0.00
Received By alange Date 2005-06-28 Time 14:08 Sent To  
Notes
2005-06-28 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-04-02 Cont ID  
Sent By tgordon Date 2007-04-02 Time 13:53 Rev Time 0.25
Received By tgordon Date 2007-04-02 Time 13:53 Sent To  
Notes
2007-04-02 13:54:40MECH. REVISION TO PLANS PAGE M.1 AND MEP.2.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2007-03-26 Cont ID  
Sent By tgordon Date 2007-03-26 Time 11:48 Rev Time 0.20
Received By tgordon Date 2007-03-26 Time 11:48 Sent To B
Notes
2007-03-26 11:54:35MECHANICAL REVISION
 *** DENIED ***
 AS NOTED IN LAST REVIEW 3-16-07
 SEE MECHANICAL PLANS PAGE MEP.2.
  
 1) TWO SUPPLY AIR GRILLS IN BEDROOM ARE SHOWN AS RETURN
 GRILLS, PLEASE CORRECT.
  
 2) 24X12 RETURN AIR GRILL IS LOCATED IN THE BATHROOM,
 PLEASE RELOCATE TO BEDROOM.
  
 3) PLEASE SHOW CFM'S AT SUPPLY GRILLS.
  
 4) SEE 12" SUPPLY AIR DUCT TO 10X6 GRILL IN BATHROOM,
 PLEASE CORRECT.
  
 5)PLEASE OBSERVE THEIR ARE TWO 10" SUPPLY AIR DUCTS
 LEAVING THE AIR HANDLER AND ONLY ONE 12" RETURN AIR
 DUCT, WHICH MAY CAUSE A UNBALANCED AIR FLOW, PLEASE
 CORRECT OR SUBMIT MANUAL J CALCULATIONS TO SHOW THE AIR
 FLOW IS BALANCED, SEE 2004 FBC/R M1602.4 AND M1401.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-03-16 Cont ID  
Sent By tgordon Date 2007-03-16 Time 15:23 Rev Time 0.30
Received By tgordon Date 2007-03-16 Time 15:23 Sent To  
Notes
2007-03-16 15:36:27MECHANICAL REVISION
 *** DENIED ***
 1) A/C SYSTEM 2 IS NOT LISTED IN EQUIPMENT LISTING,
 PLEASE SHOW PERTINENT INFORMATION FOR A/C SYSTEM 2AND
 STATE IF NEW OR EXISTING.
  
 2) TWO SUPPLY AIR GRILLS IN BEDROOM ARE SHOWN AS RETURN
 GRILLS, PLEASE CORRECT.
  
 3) 24X12 RETURN AIR GRILL IS LOCATED IN THE BATHROOM,
 PLEASE RELOCATE TO BEDROOM.
  
 4) PLEASE SHOW CFM'S AT SUPPLY GRILLS.
  
 5) SEE 12" SUPPLY AIR DUCT TO 10X6 GRILL IN BATHROOM,
 PLEASE CORRECT.
  
 6) PLEASE OBSERVE THEIR ARE TWO 10" SUPPLY AIR DUCTS
 LEAVING THE AIR HANDLER AND ONLY ONE 12" RETURN AIR
 DUCT, WHICH MAY CAUSE A UNBALANCED AIR FLOW, PLEASE
 CORRECT OR SUBMIT MANUAL J CALCULATIONS TO SHOW THE AIR
 FLOW IS BALANCED, SEE 2004 FBC/R M1602.4 AND M1401.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-05-15 Cont ID  
Sent By tgordon Date 2006-05-15 Time 14:46 Rev Time 0.30
Received By tgordon Date 2006-05-15 Time 14:46 Sent To B
Notes
2006-05-15 00:00:00REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-26 Cont ID  
Sent By prafter Date 2005-07-26 Time 09:06 Rev Time 1.00
Received By prafter Date 2005-07-26 Time 09:06 Sent To B
Notes
2005-07-26 00:00:00MECH. PLAN REVIEW:
  
 PROVISO:1. BATH #3 REQUIRE EXHAUST
 FAN IF BATH ROOM WINDOW DOES NOT COMPLY
 WITH 2003 FBC/M 402.3.1 EXCEPTION, 3 SQ.
 FT OF OPEN SPACE.
  
 2. A.H.U. #1 AND #3 REQUIRES AUX.
 DRAIN PAN UNDER UNITS WITH DRAIN
 PROTECTION. 2003 FBC/M 307.2.3.
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-05-15 Cont ID  
Sent By jleech Date 2006-05-15 Time 12:14 Rev Time 0.00
Received By jleech Date 2006-05-15 Time 12:13 Sent To M
Notes
2006-05-15 00:00:00REVISION OK

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-12-06 Cont ID  
Sent By jleech Date 2005-12-06 Time 12:50 Rev Time 0.50
Received By jleech Date 2005-12-06 Time 12:50 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-07-25 Cont ID  
Sent By jleech Date 2005-07-25 Time 08:16 Rev Time 0.50
Received By jleech Date 2005-07-25 Time 08:16 Sent To M
Notes
2005-07-25 00:00:00DENIED;
 1. AUTOMATIC CLOTHES WASHER TRAP SIZE IS
 2" SEE TABLE 709.1 FBC PLUMBING.
 2.MIMIMUN SIZE DRAINAGE PIPE UNDER
 GEOUND IS 2" NOT 1 1/2. SEC. 710.3.
 3.PLEASE SIZE ALL PIPE.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 6 Status P Date 2008-01-16 Cont ID  
Sent By choops Date 2008-01-16 Time 16:15 Rev Time 0.00
Received By choops Date 2008-01-16 Time 16:15 Sent To PC
Notes
2008-01-16 16:16:20***APPROVED - SUBMITTAL OF LANDSCAPE PLAN***

Review Stop Z ZONING
Rev No 5 Status P Date 2006-05-11 Cont ID  
Sent By mmclean Date 2006-05-11 Time 08:18 Rev Time 0.00
Received By mmclean Date 2006-05-11 Time 08:18 Sent To I
Notes
2006-05-11 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 FENCE/GATE/COLUMNS/WALL(IF APPLICABLE)
 WITH EASEMENT APPROVAL FROM THE CITY OF
 WEST PALM BEACH UTILITY DEPT. MAXIMUM
 HEIGHT ALLOWED WITHIN THE FIRST 25FT
 FRONT SETBACK IS 4FT HIGH AND BEYOND THE
 25FT FRONT SETBACK MAXIMUM HEIGHT IS 6FT
 ONLY
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK.
  
  
 REV: THE ADDITION TO THE EXISTING HOUSE
 IN THE REAR OF PROPERTY.

Review Stop Z ZONING
Rev No 4 Status P Date 2006-02-06 Cont ID  
Sent By mmclean Date 2006-02-06 Time 09:45 Rev Time 0.00
Received By mmclean Date 2006-02-06 Time 09:45 Sent To B
Notes
2006-02-06 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 FENCE/GATE/COLUMNS/WALL(IF APPLICABLE)
 WITH EASEMENT APPROVAL FROM THE CITY OF
 WEST PALM BEACH UTILITY DEPT. MAXIMUM
 HEIGHT ALLOWED WITHIN THE FIRST 25FT
 FRONT SETBACK IS 4FT HIGH AND BEYOND THE
 25FT FRONT SETBACK MAXIMUM HEIGHT IS 6FT
 ONLY
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK.
  
 NOTE: THE CARRIAGE (ACCESSORY STRUCTURE)
 REMOVED OFF THE PLANS SEE CH1-3.
  
 PLANS RETURNED TO ART LANGE.

Review Stop Z ZONING
Rev No 3 Status F Date 2006-01-25 Cont ID  
Sent By mmclean Date 2006-01-25 Time 17:16 Rev Time 0.00
Received By mmclean Date 2006-01-25 Time 17:16 Sent To B
Notes
2006-01-25 00:00:00DENIED,
 1. THE PROPOSED 2 STORY CARRIAGE HOUSE
 HOUSE (NOW ADDED TO REMODEL PERMIT) IS
 OVER THE REQUIRED SQUARE FOOTAGE FOR
 ACCESSORY STRUCTURE.
 2. ACCESSORY STRUCTURE CAN ONLY BE
 1000SQ FT. PLANS SHOWS 1600SQ FT.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/FENCE/WALL/GATE/COLUMNS WITH
 EASEMENT APPROVAL FROM THE CITY OF WEST
 PALM BEACH UTILITY DEPT
 (FENCE/GATE/WALL/COLUMNS)

Review Stop Z ZONING
Rev No 2 Status F Date 2005-12-02 Cont ID  
Sent By mmclean Date 2005-12-02 Time 14:49 Rev Time 0.00
Received By mmclean Date 2005-12-02 Time 14:49 Sent To I
Notes
2005-12-02 00:00:00DENIED,
 1. SITEPLAN & SURVEY DOES NOT MATCH
 (DIEMNSION).
 2. MUST PROVIDE A CURRENT SURVEY (SURVEY
 ENCLOSED SHOWS 1982).
 3. SITEPLAN MUST SHOW THE DIMENSION OF
 THE LOT AND ADDRESS OF PROPERTY.
  
  
 MICHELLE MCLEA
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-07-08 Cont ID  
Sent By mmclean Date 2005-07-08 Time 10:18 Rev Time 0.00
Received By mmclean Date 2005-07-08 Time 10:18 Sent To I
Notes
2005-07-08 00:00:00DENIED,
 1. MUST PROVIDE AN UPDATED SURVEY
 SHOWING THE EXISTING STRUCTURE WITH
 SETBACKS.
 2. MUST SHOW THE ADDITION WITH SETBACKS
 FOR SIDE & REAR OF PROPERTY LINE.
 3. MUST PROVIDE THE DIMENSION OF THE NEW
 DRIVEWAY WITH LENGTH & WIDTH.
 **MUST HAVE 1000SQ FT OR 75% OF
 LANDSCAPE WITHIN THE FIRST 25FT FRONT
 SETBACK.
 4. MUST PULL A SEPERATE PERMIT FOR
 POOL/DECK/SPA/FENCE/WALL/COLUMNS (IF
 APPLICABLE).
 5. FENCE MUST HAVE A UTILITY EASMENT
 APPROVAL FROM THE CITY OF WEST PALM
 BEACH UTILITY DEPT.
 6. COLUMNS AND GATES CAN ONLY BE A
 MAXIMUM OF 6FT IN HEIGHT BEYOND THE 25FT
 FRONT SETBACK.ANY FENCE/COLUMNS/GATE
 WITHIN THE 25FT FRONT SETBACK CAN ONLY
 BE A MAXIMUM OF 4FT HIGH.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved