| Plan Review Stops For Permit 05061664 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-03-28 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-28 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2007-03-28 11:23:23 | | | | | | | SITE WALL REQUIRES SEPERATE PERMIT. | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-20 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-20 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-17 |
Time |
11:39 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-05-17 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2006-05-17 00:00:00 | STRUCTURAL REV OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-16 |
Time |
08:49 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-05-16 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2006-05-16 00:00:00 | ADDED NEW ROOM ADDITION TO EXISTING PLAN | | | OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-06 |
Time |
11:10 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-02-06 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-09 |
Time |
14:45 |
Rev Time |
2.50 |
| Received By |
alange |
Date |
2005-12-09 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2005-12-09 00:00:00 | DENIED | | | | | | 4. PROPERTY IS IN FLOOD ZONE "A" . | | | A.SHOW ON PLANS HOW COTTAGE AND ROOM | | | ADDITION WILL BE 6" ABOVE THE BASE | | | ELEVATION OF 7FT. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-01 |
Time |
08:59 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2005-08-01 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2005-08-01 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.PROPERTY IS IN AN AREA OF | | | QUESTIONABLE SOILS. SUBMIT TWO ORIGONALS | | | OF A SOILS REPORT. | | | | | | 4. PROPERTY IS IN FLOOD ZONE "A" SUBMIT | | | AN ELEVATION CERTIFICATE. | | | A.SHOW ON PLANS HOW COTTAGE WILL BE 6" | | | ABOVE THE BASE ELEVATION OF 7FT. | | | | | | B.ALL NEW CONSTRUCTION OR SUBSTANTIAL | | | IMPROVMENT OF ANY EXISTING RESIDENTIAL | | | STRUCTURE SHALL HAVE THE LOWEST FLOOR | | | ELEVATED TO SIX INCHES ABOVE THE BASE | | | FLOOD ELEVATION. WPB MUNI-CODE 94-546 | | | (B) (1) | | | SHOW FINISH FLOOR HEIGHT OF EXISTING | | | BUILDING AND ROOM ADDITION. | | | | | | 5.SHOW SIZE AND LOCATION OF ATTIC | | | ACCESS COMPLYING WITH FBC 2309.6 | | | | | | 6. SHOW METHOD OF ATTIC VENTILATION. | | | FBC 2309.7.1 | | | | | | 7.SUBMIT A GUARD RAIL DETAIL SHOWING | | | COMPLIANCE WITH FBC CHAPTER 10 | | | | | | 8.BASED ON SBCCI BUILDING VALUATION | | | DATA THE PERMIT VALUATION HAS BEEN | | | REVISED TO $329,328.00 ADDITIONAL PERMIT | | | FEES ARE DUE. | | | | | | 9.SQUARE FOOTAGE ON APPLICATION HAS | | | BEEN REVISED. | | | | | | 10. PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE REQUIRED FOR THE FOLLOWING | | | ITEMS:ROOFING, EXTERIOR DOORS AND | | | WINDOWS, IMPACT PROTECTION, HARDIE | | | SIDING, AND STRAPS AND TIE-DOWNS. | | | ALL PRODUCT APPROVALS SUBMITTED SHALL | | | HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-02 |
Time |
13:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-04-02 |
Time |
12:40 |
Sent To |
M |
|
| Notes |
| 2007-04-02 13:33:17 | REV # 7INDICATED LOW VOLTAGE SYSTEM, FOR FINAL./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-20 |
Time |
07:23 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-20 |
Time |
06:41 |
Sent To |
M |
|
| Notes |
| 2007-03-20 07:20:31 | | | | | | | SHEET MEP-2 SUBMITTED 3/15/07, SAME SHEET REVISION THAT | | | WAS SUBMITTED ON 3/9/07? | | | | | | WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-16 |
Time |
14:04 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-03-16 |
Time |
13:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-12 |
Time |
07:41 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-05-12 |
Time |
06:31 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-01-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-01-24 |
Time |
16:52 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-01-24 |
Time |
13:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-12-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-06 |
Time |
11:23 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2005-12-06 |
Time |
06:19 |
Sent To |
P |
|
| Notes |
| 2005-12-06 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} CAN'T FIND MANUFACTURERS | | | SPECIFICATIONS FOR THE GENERATOR AND | | | ATS. | | | | | | 2} THE LOAD CALC SHOWN FOR PANEL "SB"(79 | | | AMPS) EXCEEDS THE SHOWN GENERATOR OUTPUT | | | OF 59 AMPS. PLEASE CLARIFY. | | | | | | 3} PLEASE CONFIRM THAT FPL IS PROVIDING | | | GRC FOR THE SERVICE. TYPICALLY THIS | | | WOULD BE PVC. ALSO 2-4/0 CONDUCTORS WILL | | | NOT BE RUN WITH THE CABLE. THIS SECTION | | | OF THE RISER MAY BE LEFT BLANK IF | | | SUPPLIED BY FPL. THE DESIGNER ONLY NEEDS | | | TO INDICATE THE SIZE OF THE MAIN BREAKER | | | AND THE SERVICE CONDUCTORS FROM THAT | | | POINT. | | | | | | 4} THE 250 MCM CONDUCTORS FROM 400 AMP | | | MAIN ARE IN VIOLATION OF 310.15(B)(6), | | | THEY MUST BE A MINIMUM OF 500 MCM. | | | | | | 5} THE TWO 4/0 "GROUNDS" SHOWN FROM THE | | | METER/MAIN TO THE GUTTER ARE INCORRECT. | | | ONE CONDUCTOR WOULD BE A NEUTRAL, AND | | | THE OTHER A GROUND. THEY WOULD NOT BE | | | THE SAME SIZE. SEE 250.122 FOR EQUIPMENT | | | GROUND AND 310-15 FOR THE NEUTRAL SIZE. | | | | | | 6} SHEET E.1 INDICATES PANELS "C,H,AND | | | SB". SHEET E-2 RISER HAS DIFFERENT | | | DESIGNATIONS, PLEASE CORRELATE. | | | | | | 7} PANEL "H" IS SHOWN AS MLO (SCHEDULE). | | | MUST HAVE THE MAIN INDICATED ON | | | METER/MAIN. | | | | | | 8} THE FEED FROM THE GUTTER TO THE 125 | | | AMP DISCONNECT MARKED (CH) DOES NOT HAVE | | | A NEUTRAL. THE OTHER TWO DISCONNECTS DO | | | NOT HAVE A GROUND. | | | | | | 9} THE PANELS INTHE LAUNDRY ROOM DO NOT | | | HAVE THE CLEARANCE REQUIREMENTS OF | | | 110.26. | | | | | | 10} SEE 250.32(B)(1) FOR EQUIPMENT | | | GROUND REQUIREMENT TO SEPERATE | | | STRUCTURES. THE FEED TO THE CARRIAGE | | | HOUSE MUST COMPLY. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-21 |
Time |
10:11 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2005-07-21 |
Time |
07:03 |
Sent To |
M |
|
| Notes |
| 2005-07-21 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE PROVIDE MANUFACTURERS | | | SPECIFICATIONS FOR THE GENERATOR AND | | | TRANSFER SWITCH SHOWN ON THE RISER | | | DIAGRAM. | | | | | | 2} INDICATE THE SERVICE CONDUCTOR AND | | | CONDUIT SIZE(S) FROM THE METER TO THE | | | GUTTER. 215.5. | | | | | | 3} INDICATE TAP CONDUCTOR AND CONDUIT | | | SIZES FROM THE GUTTER TO THE DISCONNECTS | | | | | | ON THE RISER. 215.5. | | | | | | 4} PLEASE SHOW A SITE PLAN LOCATING ALL | | | SERVICE AND STANDBY EQUIPMENT. PLEASE | | | NOTE IF THE 125 AMP PANEL ON THE RISER | | | IS LOCATED AT OR ON THE CARRIAGE HOUSE | | | IT MUST CONTAIN A MAIN BREAKER. A | | | DISCONNECT MUST BE SUPPLIED PER 225.31. | | | ALSO SEE 250.30 FOR GROUNDING | | | REQUIREMENTS, NOT INDICATED ON THE | | | RISER. | | | | | | 5} PLEASE GIVE A LOAD CALCULATION FOR | | | THE STANDBY PANEL. SEE 702.5, ALL | | | CIRCUITS HAVE LOADS, 5 ARE LISTED WITH | | | NO LOADS ON THE SCHEDULE. | | | | | | 6} THE 3/0 CONDUCTORS RUN FROM THE 400 | | | AMP DISCONNECT TO THE 400 AMP PANEL DO | | | NOT COMPLY WITH 310.16 AMPERAGE | | | REQUIREMENTS. | | | | | | 7} THE LAUNDRY CIRCUIT MUST COMPLY WITH | | | 210.11(C)(2). 20 AMP #12 BC. | | | | | | 8) PLEASE SEE THE CONDUCTOR AND OCP SIZE | | | | | | FOR THE AHU AND A/C UNIT #1 ARE | | | INCORRECT. 310.16. PLEASE VERIFY THE | | | NAMEPLATE AT 17KVA ON AC#1. | | | | | | 7} THERE IS ONLY 1 SMALL APPLIANCE | | | CIRCUIT LISTED ON THE PANEL SCHEDULE. | | | SEE 210.11(C)(1). | | | | | | 8) THERE ARE 2 WATER HEATERS IN THE | | | CALCULATION, ONLY ONE LISTED ON | | | SCHEDULES. ALSO SEE THAT ONE LEG IS A | | | #10 AND THE OTHER A #12 ON THE ONE | | | SHOWN. | | | | | | 9} THE REFER AND SM APP CIRCUITS ON | | | SCHED "SB" ARE SHOWN AS 2 POLE, PLEASE | | | CORRECT. | | | | | | 10} LIST THE NEW BATH CIRCUITS PER | | | 210.11(C)(3), INCLUDING CARRIAGE HOUSE, | | | IN RESPECTIVE PANELS. | | | | | | IF THEERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-03-26 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-03-26 |
Time |
18:28 |
Sent To |
E |
|
| Notes |
| 2007-03-29 15:53:43 | TO BT'S DESK ON 3/29 | | 2007-03-26 18:29:14 | TO DEWEY PALMER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-12 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-12 |
Time |
09:44 |
Sent To |
E |
|
| Notes |
| 2007-03-12 09:45:01 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-14 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-14 |
Time |
14:55 |
Sent To |
B |
|
| Notes |
| 2006-11-14 14:55:51 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-11 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-11 |
Time |
16:06 |
Sent To |
E |
|
| Notes |
| 2006-05-11 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-11 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-11 |
Time |
13:01 |
Sent To |
B |
|
| Notes |
| 2006-05-11 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-25 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-25 |
Time |
09:17 |
Sent To |
Z |
|
| Notes |
| 2006-04-25 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-04 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-04 |
Time |
15:10 |
Sent To |
Z |
|
| Notes |
| 2006-01-04 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-05 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-05 |
Time |
10:13 |
Sent To |
E |
|
| Notes |
| 2005-12-05 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-18 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-18 |
Time |
09:10 |
Sent To |
Z |
|
| Notes |
| 2005-11-18 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-08 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-08 |
Time |
14:17 |
Sent To |
E |
|
| Notes |
| 2005-07-08 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-01 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-06-28 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2005-06-28 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-02 |
Time |
13:53 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-04-02 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2007-04-02 13:54:40 | MECH. REVISION TO PLANS PAGE M.1 AND MEP.2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-26 |
Time |
11:48 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-03-26 |
Time |
11:48 |
Sent To |
B |
|
| Notes |
| 2007-03-26 11:54:35 | MECHANICAL REVISION | | | *** DENIED *** | | | AS NOTED IN LAST REVIEW 3-16-07 | | | SEE MECHANICAL PLANS PAGE MEP.2. | | | | | | 1) TWO SUPPLY AIR GRILLS IN BEDROOM ARE SHOWN AS RETURN | | | GRILLS, PLEASE CORRECT. | | | | | | 2) 24X12 RETURN AIR GRILL IS LOCATED IN THE BATHROOM, | | | PLEASE RELOCATE TO BEDROOM. | | | | | | 3) PLEASE SHOW CFM'S AT SUPPLY GRILLS. | | | | | | 4) SEE 12" SUPPLY AIR DUCT TO 10X6 GRILL IN BATHROOM, | | | PLEASE CORRECT. | | | | | | 5)PLEASE OBSERVE THEIR ARE TWO 10" SUPPLY AIR DUCTS | | | LEAVING THE AIR HANDLER AND ONLY ONE 12" RETURN AIR | | | DUCT, WHICH MAY CAUSE A UNBALANCED AIR FLOW, PLEASE | | | CORRECT OR SUBMIT MANUAL J CALCULATIONS TO SHOW THE AIR | | | FLOW IS BALANCED, SEE 2004 FBC/R M1602.4 AND M1401.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-16 |
Time |
15:23 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-16 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2007-03-16 15:36:27 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) A/C SYSTEM 2 IS NOT LISTED IN EQUIPMENT LISTING, | | | PLEASE SHOW PERTINENT INFORMATION FOR A/C SYSTEM 2AND | | | STATE IF NEW OR EXISTING. | | | | | | 2) TWO SUPPLY AIR GRILLS IN BEDROOM ARE SHOWN AS RETURN | | | GRILLS, PLEASE CORRECT. | | | | | | 3) 24X12 RETURN AIR GRILL IS LOCATED IN THE BATHROOM, | | | PLEASE RELOCATE TO BEDROOM. | | | | | | 4) PLEASE SHOW CFM'S AT SUPPLY GRILLS. | | | | | | 5) SEE 12" SUPPLY AIR DUCT TO 10X6 GRILL IN BATHROOM, | | | PLEASE CORRECT. | | | | | | 6) PLEASE OBSERVE THEIR ARE TWO 10" SUPPLY AIR DUCTS | | | LEAVING THE AIR HANDLER AND ONLY ONE 12" RETURN AIR | | | DUCT, WHICH MAY CAUSE A UNBALANCED AIR FLOW, PLEASE | | | CORRECT OR SUBMIT MANUAL J CALCULATIONS TO SHOW THE AIR | | | FLOW IS BALANCED, SEE 2004 FBC/R M1602.4 AND M1401.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-15 |
Time |
14:46 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-15 |
Time |
14:46 |
Sent To |
B |
|
| Notes |
| 2006-05-15 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-07-26 |
Time |
09:06 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-07-26 |
Time |
09:06 |
Sent To |
B |
|
| Notes |
| 2005-07-26 00:00:00 | MECH. PLAN REVIEW: | | | | | | PROVISO:1. BATH #3 REQUIRE EXHAUST | | | FAN IF BATH ROOM WINDOW DOES NOT COMPLY | | | WITH 2003 FBC/M 402.3.1 EXCEPTION, 3 SQ. | | | FT OF OPEN SPACE. | | | | | | 2. A.H.U. #1 AND #3 REQUIRES AUX. | | | DRAIN PAN UNDER UNITS WITH DRAIN | | | PROTECTION. 2003 FBC/M 307.2.3. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-15 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-05-15 |
Time |
12:13 |
Sent To |
M |
|
| Notes |
| 2006-05-15 00:00:00 | REVISION OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-12-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-06 |
Time |
12:50 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-06 |
Time |
12:50 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-25 |
Time |
08:16 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-07-25 |
Time |
08:16 |
Sent To |
M |
|
| Notes |
| 2005-07-25 00:00:00 | DENIED; | | | 1. AUTOMATIC CLOTHES WASHER TRAP SIZE IS | | | 2" SEE TABLE 709.1 FBC PLUMBING. | | | 2.MIMIMUN SIZE DRAINAGE PIPE UNDER | | | GEOUND IS 2" NOT 1 1/2. SEC. 710.3. | | | 3.PLEASE SIZE ALL PIPE. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-16 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-16 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
| 2008-01-16 16:16:20 | ***APPROVED - SUBMITTAL OF LANDSCAPE PLAN*** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-11 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-11 |
Time |
08:18 |
Sent To |
I |
|
| Notes |
| 2006-05-11 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/GATE/COLUMNS/WALL(IF APPLICABLE) | | | WITH EASEMENT APPROVAL FROM THE CITY OF | | | WEST PALM BEACH UTILITY DEPT. MAXIMUM | | | HEIGHT ALLOWED WITHIN THE FIRST 25FT | | | FRONT SETBACK IS 4FT HIGH AND BEYOND THE | | | 25FT FRONT SETBACK MAXIMUM HEIGHT IS 6FT | | | ONLY | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA/DECK. | | | | | | | | | REV: THE ADDITION TO THE EXISTING HOUSE | | | IN THE REAR OF PROPERTY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-06 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-06 |
Time |
09:45 |
Sent To |
B |
|
| Notes |
| 2006-02-06 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/GATE/COLUMNS/WALL(IF APPLICABLE) | | | WITH EASEMENT APPROVAL FROM THE CITY OF | | | WEST PALM BEACH UTILITY DEPT. MAXIMUM | | | HEIGHT ALLOWED WITHIN THE FIRST 25FT | | | FRONT SETBACK IS 4FT HIGH AND BEYOND THE | | | 25FT FRONT SETBACK MAXIMUM HEIGHT IS 6FT | | | ONLY | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA/DECK. | | | | | | NOTE: THE CARRIAGE (ACCESSORY STRUCTURE) | | | REMOVED OFF THE PLANS SEE CH1-3. | | | | | | PLANS RETURNED TO ART LANGE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-25 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-25 |
Time |
17:16 |
Sent To |
B |
|
| Notes |
| 2006-01-25 00:00:00 | DENIED, | | | 1. THE PROPOSED 2 STORY CARRIAGE HOUSE | | | HOUSE (NOW ADDED TO REMODEL PERMIT) IS | | | OVER THE REQUIRED SQUARE FOOTAGE FOR | | | ACCESSORY STRUCTURE. | | | 2. ACCESSORY STRUCTURE CAN ONLY BE | | | 1000SQ FT. PLANS SHOWS 1600SQ FT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/FENCE/WALL/GATE/COLUMNS WITH | | | EASEMENT APPROVAL FROM THE CITY OF WEST | | | PALM BEACH UTILITY DEPT | | | (FENCE/GATE/WALL/COLUMNS) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-02 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-02 |
Time |
14:49 |
Sent To |
I |
|
| Notes |
| 2005-12-02 00:00:00 | DENIED, | | | 1. SITEPLAN & SURVEY DOES NOT MATCH | | | (DIEMNSION). | | | 2. MUST PROVIDE A CURRENT SURVEY (SURVEY | | | ENCLOSED SHOWS 1982). | | | 3. SITEPLAN MUST SHOW THE DIMENSION OF | | | THE LOT AND ADDRESS OF PROPERTY. | | | | | | | | | MICHELLE MCLEA | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-08 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-08 |
Time |
10:18 |
Sent To |
I |
|
| Notes |
| 2005-07-08 00:00:00 | DENIED, | | | 1. MUST PROVIDE AN UPDATED SURVEY | | | SHOWING THE EXISTING STRUCTURE WITH | | | SETBACKS. | | | 2. MUST SHOW THE ADDITION WITH SETBACKS | | | FOR SIDE & REAR OF PROPERTY LINE. | | | 3. MUST PROVIDE THE DIMENSION OF THE NEW | | | DRIVEWAY WITH LENGTH & WIDTH. | | | **MUST HAVE 1000SQ FT OR 75% OF | | | LANDSCAPE WITHIN THE FIRST 25FT FRONT | | | SETBACK. | | | 4. MUST PULL A SEPERATE PERMIT FOR | | | POOL/DECK/SPA/FENCE/WALL/COLUMNS (IF | | | APPLICABLE). | | | 5. FENCE MUST HAVE A UTILITY EASMENT | | | APPROVAL FROM THE CITY OF WEST PALM | | | BEACH UTILITY DEPT. | | | 6. COLUMNS AND GATES CAN ONLY BE A | | | MAXIMUM OF 6FT IN HEIGHT BEYOND THE 25FT | | | FRONT SETBACK.ANY FENCE/COLUMNS/GATE | | | WITHIN THE 25FT FRONT SETBACK CAN ONLY | | | BE A MAXIMUM OF 4FT HIGH. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|