Plan Review Details - Permit 05061441
Plan Review Stops For Permit 05061441
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-08-17 Cont ID  
Sent By alange Date 2005-08-17 Time 13:42 Rev Time 0.50
Received By alange Date 2005-08-17 Time 13:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-08-09 Cont ID  
Sent By alange Date 2005-08-09 Time 08:21 Rev Time 0.33
Received By alange Date 2005-08-09 Time 08:19 Sent To  
Notes
2005-08-09 00:00:00DENIED
  
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 2. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 3. PROPERTY IS IN FLOOD ZONE "A" SHOW
 GENERATOR SLAB AT 6" ABOVE THE BASE
 FLOOD ELEVATION OF 7FT.
 PLANS ARE SHOWN AT 6" ABOVE GRADE.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-29 Cont ID  
Sent By alange Date 2005-07-29 Time 08:34 Rev Time 0.50
Received By alange Date 2005-07-29 Time 08:19 Sent To  
Notes
2005-07-29 00:00:00DENIED
  
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1. PROVIDE ANCHORING INFORMATION TO
 COMPLY WITH FBC1606.1.3; STRUCTURAL
 MEMBERS AND SYSTEMS, AND COMPONENTS AND
 CLADDING IN A BUILDING OR STRUCTURE
 SHALL BE ANCHORED TO RESIST WIND-INDUCED
 OVERTURNING, UPLIFT AND SLIDING AND TO
 PROVIDE CONTINUOUS LOAD PATHS FOR THESE
 FORCES TO THE FOUNDATION.WHERE A
 PORTION OF THE RESISTANCE TO THESE
 FORCES IS PROVIDED BY DEAD LOAD, THE
 MINIMUM DEAD LOAD LIKELY TO BE IN PLACE
 DURING A DESIGN WIND EVENT SHALL BE
 USED.
  
 2. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 3. PROPERTY IS IN FLOOD ZONE "A" SHOW
 GENERATOR SLAB A 6" ABOVE THE BASE FLOOD
 ELEVATION OF 7FT.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-01-11 Cont ID  
Sent By btrobaug Date 2006-01-11 Time 13:03 Rev Time 0.50
Received By btrobaug Date 2006-01-11 Time 12:34 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-07-06 Cont ID  
Sent By btrobaug Date 2005-07-06 Time 17:39 Rev Time 0.50
Received By btrobaug Date 2005-07-06 Time 17:31 Sent To Z
Notes
2005-07-06 00:00:00 
  
 PLEASE SUBMIT AN ELEVATION CERTIFICATE.
 MOST OF FLAGLER IS IN ZONE "A". CALL
 SURVEYOR FOR INFORMATION.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-11 Cont ID  
Sent By adarroug Date 2005-08-11 Time 18:49 Rev Time 0.00
Received By adarroug Date 2005-08-11 Time 18:49 Sent To B
Notes
2005-08-11 00:00:00TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-08 Cont ID  
Sent By adarroug Date 2005-08-08 Time 16:30 Rev Time 0.00
Received By adarroug Date 2005-08-08 Time 16:30 Sent To B
Notes
2005-08-08 00:00:00TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-29 Cont ID  
Sent By adarroug Date 2005-07-29 Time 15:03 Rev Time 0.00
Received By adarroug Date 2005-07-29 Time 15:03 Sent To Z
Notes
2005-07-29 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-19 Cont ID  
Sent By adarroug Date 2005-07-19 Time 15:10 Rev Time 0.00
Received By adarroug Date 2005-07-19 Time 15:10 Sent To B
Notes
2005-07-19 00:00:00TO "RES" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-24 Cont ID  
Sent By adarroug Date 2005-06-24 Time 16:19 Rev Time 0.00
Received By adarroug Date 2005-06-24 Time 16:19 Sent To E
Notes
2005-06-24 00:00:00TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-11 Cont ID  
Sent By rregueir Date 2005-07-11 Time 11:35 Rev Time 0.00
Received By rregueir Date 2005-07-11 Time 11:35 Sent To G
Notes
2005-07-11 00:00:00---------------PROVISO------------------
 GENERATOR EXHAUST TERMINATION TO
 TERMINATE MIN. 10' FROM OPENINGS INTO
 BUILDING STRUCTURE (DOORS, WINDOWS) AND
 IN COMPLIANCE WITH FBC,M 804.3
  
 RONALD J REGUEIRO
 561-805-6734
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-07-18 Cont ID  
Sent By jleech Date 2005-07-18 Time 09:56 Rev Time 0.50
Received By jleech Date 2005-07-18 Time 09:56 Sent To Z
Notes
2005-07-18 00:00:00NO GAS APPLICATION HAS BEEN RECIEVED AS
 OF 7/18/2005.

Review Stop Z ZONING
Rev No 2 Status P Date 2005-08-05 Cont ID  
Sent By mmclean Date 2005-08-05 Time 11:06 Rev Time 0.00
Received By mmclean Date 2005-08-05 Time 11:06 Sent To I
Notes
2005-08-05 00:00:00GENERATOR CAN ONLY ENROACH 4FT INTO
 SETBACK.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-07-18 Cont ID  
Sent By mmclean Date 2005-07-18 Time 10:39 Rev Time 0.00
Received By mmclean Date 2005-07-18 Time 10:39 Sent To I
Notes
2005-07-18 00:00:00DENIED,
 1. MUST PROVIDE THE REAR & SIDE SETBACK
 OF THE GENERATOR. MUST BE WRITTEN ON TWO
 COPY OF SURVEY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720