| Plan Review Stops For Permit 05061374 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-10 |
Time |
11:53 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-02-10 |
Time |
11:53 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-01-30 |
Time |
12:58 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-01-30 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2006-01-30 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05061374 | | | ADD: 900 S OLIVE | | | CONT: PURDY CONST | | | TEL: (561)718-8082 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1)COMMENT# 1 FROM THE PREVIOUS REVIEW, | | | PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | NOTE WHEN WORK HAS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING NOC IT IS NULL AND | | | VOID.FAC 713.13.(2). | | | | | | 2) COMMENT#2 FROM THE PREVIOUS REVIEW: | | | DELT WITH THE BUILDING CLASSIFICATION, | | | PLANS NOW INDICATEW A TYPE II-A WHICH IS | | | A 2004 CLASSIFICATION, THIS PLAN IS A | | | 2001 PLAN.RE-CLASSIFY TO THE 2001 FBC. | | | | | | 3A)COMMENT # 4 FROM THE PREVIOUS REVIEW, | | | DEPENDING ON THE RESULTS OF QUESTION | | | NUMBER TWO DETAIL #2 ON S-2 MAY OR MAY | | | NOT HAVE COMBUSTIBLE WALLS & ROOF | | | FRAMING MEMBERS & SHEATHING. TABLE 600. | | | EXTERIOR BEARING WALLS ARE TO BE | | | NON-COMBUSTIBLEAND A 3HR FIRE RATING. | | | THE ROOF FRAMING IS TO BE FIRE RETARDANT | | | TREATED WOOD WHEN THE BUILDING IS NOT | | | OVER 2 STORIES WITH A 1 HR FIRE RATING, | | | PLANS DO NOT INDICATE COMPLIANCE WITH | | | FIRE RATING. | | | | | | 4) COMMENT# 5FROM THE PEVIOUS REVIEW, | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5) COMMENT# 6FROM THE PREVIOUS REVIEW, | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) ROOFING ASSEMBLIES | | | B) TRUSS STRAPS | | | C) EXTERIOR COOLER IF PART OF THIS | | | PERMIT!!!!!!! | | | | | | 6) COMMENT# 7 FROM THE PREVIOUS REVIEW, | | | STAIRS TO HAVE A HANDRAIL BOTH SIDES | | | 1007.5.2 STAIRWAYS SHALL HAVE HAND- | | | RAILS ON EACH SIDE. | | | THE ARCHETECTURAL AND STRUCTURAL PLANS | | | NEED TO MATCH. THE A SHEETS INDICATE 4 | | | RISERS WHILE THE STRUCTURAL INDICATE 5 | | | RISERS 5X7"= 35" REQUIRING GUARDRAILS | | | AND HANDRAILS. | | | 7) COMMENT# 8 FROM THE PREVIOUS REVIEW, | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-18 |
Time |
16:36 |
Rev Time |
1.33 |
| Received By |
lmartine |
Date |
2005-11-18 |
Time |
15:28 |
Sent To |
Z |
|
| Notes |
| 2005-11-18 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05061374 | | | ADD: 900 S OLIVE | | | CONT: PURDY CONST | | | TEL: (561)718-8082 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) COMMENT#2 FROM THE PREVIOUS REVIEW: | | | PLANS DO NOT PROVIDE THE BUILDING | | | CLASSIFICATION BY TYPE OF CONSTRUCTION. | | | | | | 3)COMMENT # 4 FROM THE PREVIOUS REVIEW, | | | DEPENDING ON THE RESULTS OF QUESTION | | | NUMBER TWO DETAIL #2 ON S-2 MAY OR MAY | | | NOT HAVE COMBUSTIBLE WALLS & ROOF | | | FRAMING MEMBERS & SHEATHING. TABLE 600. | | | WHY DOES THE PLYWOOD STOP SHORT OF THE | | | TOP PLATE?IF LEFT THIS WAY | | | FIREBLOCKING REQUIRED AT THE TOP OF | | | PLYWOOD. | | | | | | 4) COMMENT# 5FROM THE PEVIOUS REVIEW, | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5) COMMENT# 6FROM THE PREVIOUS REVIEW, | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) ROOFING ASSEMBLIES | | | B) TRUSS STRAPS | | | | | | 6) COMMENT# 7 FROM THE PREVIOUS REVIEW, | | | STAIRS TO HAVE A HANDRAIL BOTH SIDES | | | 1007.5.2 STAIRWAYS SHALL HAVE HAND- | | | RAILS ON EACH SIDE. | | | | | | 7) COMMENT# 8 FROM THE PREVIOUS REVIEW, | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-24 |
Time |
14:02 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-07-24 |
Time |
14:02 |
Sent To |
PC |
|
| Notes |
| 2005-07-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05061374 | | | ADD: 900 S OLIVE | | | CONT: PURDY CONST | | | TEL: (561)718-8082 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PLANS DO NOT PROVIDE THE BUILDING | | | CLASSIFICATION BY TYPE OF CONSTRUCTION. | | | | | | 3) PLANS INDICATE A LANDING THAT HAS THE | | | LANDING DECREASED BY A EXISTING | | | CONCREETE CURB. 1007.4.2THE WIDTH OF | | | LANDINGS SHALL BE NOT LESS | | | THAN THE WIDTH OF STAIRWAYS THEY | | | SERVE. | | | | | | 4) DEPENDING ON THE RESULTS OF QUESTION | | | NUMBER TWO DETAIL #2 ON S-2 MAY OR MAY | | | NOT HAVE COMBUSTIBLE WALLS & ROOF | | | FRAMING MEMBERS & SHEATHING. TABLE 600. | | | WHY DOES THE PLYWOOD STOP SHORT OF THE | | | TPO PLATE?IF LEFT THIS WAY | | | FIREBLOCKING REQUIRED AT THE TOP OF | | | PLYWOOD. | | | | | | | | | 5)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) ROOFING ASSEMBLIES | | | B) TRUSS STRAPS | | | | | | 7) STAIRS TO HAVE A HANDRAIL BOTH SIDES | | | 1007.5.2 STAIRWAYS SHALL HAVE HAND- | | | RAILS ON EACH SIDE. | | | | | | 8)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-18 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-18 |
Time |
18:00 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-05 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-05 |
Time |
15:10 |
Sent To |
PC |
|
| Notes |
| 2006-12-05 15:37:34 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE KNOW WHEN SUBMITTING REVISIONS ON PLANS | | | WHICH WERE ORIGINALLY DONE UNDER A BUILDING PERMIT | | | NUMBER; PLEASE BE SURE WHEN SUBMITTING THE REVISIONS TO | | | INDICATE # 05061374 | | | | | | 2) NOTE: PLEASE 250.50, THE GROUNDING ELECTRODE | | | ATTACHMENT SHOULD BE MORE THAN THE CWP, AS THIS | | | BUILDING WOULD HAVE OTHER REQUIRED ATTACHMENT POINTS. | | | PLEASE KNOW IF THE CWP AT THE LOCATION OF THE | | | TRANSFORMER CONTAIN CPVC ANYWHERE IN THE SYSTEM BEFORE | | | IT ACTUALLY ORIGINATES, THEN THE ATTACHMENT WOULD NOT | | | PROVIDE A SUFFICIENT RESISTANCE OR BE PART OF THE | | | BUILDING?S SYSTEM. | | | | | | 3) NOTE: PLEASE SEE PANEL KPR SEEMS TO INDICATE THE | | | TRANSFORMER KVA SIZE AS 15K, WHERE AS THE RISER SHOWS | | | 50. | | | PLEASE KNOW THIS PART CAN NOT BE REVIEWED FOR THE | | | CORRECT OCP ETC WITH OUT FIRST KNOWING WHICH SIZE IS | | | ACCURATE. | | | PLEASE SEE THE LOAD IS BEING SHOWN HIGHER THAN THAT OF | | | A 15KVA UNIT. | | | 240.21, 450.3, 310.16, 240.4, ETC. | | | | | | 4) NOTE: PLEASE KNOW, BASED ON THE COMMENT #3, THE | | | LOADS BACK TO PANEL PP1 HAVE NOT BEEN IDENTIFIED BASED | | | ON THE OCP AND FEED TO THE EXISTING PANEL KPR. | | | 220 | | | | | | 5) NOTE: PLEASE KNOW WHEN PLANS ARE NOT DONE BY AN | | | ARCHITECT OR ENGINEER AND DONE BY THE CONTRACTOR, THE | | | PERSON TAKING RESPONSIBILITY OF THE PLANS SHALL CLEARLY | | | PRINT AND SIGN THEIR NAME. | | | FBC106.1.2 ADMIN SECTION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-24 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-24 |
Time |
14:52 |
Sent To |
PC |
|
| Notes |
| 2006-10-24 15:03:29 | ***UNSAT ** | | | | | | 1) NOTE: PLEASE SEE NEW SCOPE OF WORK AND RISER | | | INCLUDES NEW WORK FOR 277/480V WHICH IS REQUIRED TO BE | | | DONE BY A PE. | | | PLEASE SEE FS 471.003(2)(H)2A) | | | | | | 2) NOTE: PLEASE SEE LOCATION OF THE NEW GROUNDIGN | | | ELECTRODE SYSTEM FORTHE NEW SD SYSTEM IS NOT SHOWN. | | | ATTACHMENT ETC. 250.66, 250.50,250.30,250.20 | | | | | | 3) NOTE: PLEASE SEE RISER SHOWS A NUETRAL CONDUCTOR | | | BEING INSTALLED TO THE SD SYSTEM??? | | | | | | 4) NOTE: PLEASE SEE NO OCP SHOWN FOR NEW FEED FROM | | | EXISTING KPR? 450.3. , | | | SHOWS 3KVA TRANSFORMER? | | | | | | 5) NOTE: PLEASE SUBMIT LOAD CALCULATIONS FOR ALL | | | INCREASED AND ADDED LOADS. | | | | | | THESE NOTES ARE PRELIMINARYBASED ON THE RISER | | | SUIBMITTED, HOWEVER ONCE PLANS SUBMITTED DONE BY AN PE, | | | A REVIEW WILL COMMENCE ON THOSE SAID PLANS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER. | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2006-10-24 14:54:13 | REVISION RECEIVED FROM FRONT COUNTER SUPREVISOR ON | | | 10/23/06 AS THIS WAS SUBMITTED IN ERROR UNDER THE WRONG | | | PERMIT NUMBER. (06082172) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-10 |
Time |
20:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-10 |
Time |
20:19 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | OK, STAMPED. | | | REDLINED MISSING EQUIPMENT GROUNDING | | | CONDUCTOR TO NEW SUB-PANEL. | | | VIF. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-14 |
Time |
20:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-11-18 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2005-07-14 00:00:00 | ** UNSAT ** | | | | | | PLEASE SEE THE PLANS ARE COMNING BACK | | | DUE TO ZONING COMMENTS. PLEASE MAKE THE | | | BELOW CORRECTIONS AT THIS TIME. | | | | | | 1)NOTE: PLEASE SHOW LOAD FOR EXISTING | | | PANEL "LG". PLEASE SEE PLANS MENTIONS TO | | | REMOVE A COOLER/FREEZER CIRCUIT AND | | | INSTALL NEW 50A BRKR FOR NEWSUB-PANEL, | | | HOWEVER WHAT SIZE WAS EXISTING BRKR? WAS | | | THERE AN INCREASE IN LOAD? | | | 220,215.5 | | | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM EXISTING PANEL | | | TO NEW SUB PANEL. | | | 250.110,250.24,250.122 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-20 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-20 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | ******PROVISO****** | | | | | | IN REFERENCE TO HANDRAILS, PLEASE REFER | | | TO NFPA 101, 2003 EDITION SEC. | | | 7.2.2.4.1.1. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-11-15 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-11-15 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | DENIED | | | | | | 1) PLEASE PROVIDE STAIRS DETAIL OR SHOW | | | THE HANDRAILS AND GUARDS ON THE FLOOR | | | PLAN. | | | | | | 2) AGAIN WILL THE NEW WALK-IN COOLER | | | IMPACT EXISTING MEANS OF EGRESS? | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-20 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-20 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2005-07-20 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE NOTE THAT APPROVAL HAS NOT | | | BEEN OBTAINED BY ZONING. | | | | | | 2) HANDRAILS ARE REQUIRED ON BOTH SIDES | | | OF STAIRS. GUARDS SHALL BE PROVIDED AT | | | OPEN SIDES OF STAIRS IF GREATER THAN 30" | | | FROM GRADE LEVEL. | | | | | | 3) WILL THE NEW WALK IN COOLER IMPACT | | | EXISTING MEANS OF EGRESS? | | | | | | | | | MIKE WENNERGREN, CAPTAIN | | | WPBFR(561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-16 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-16 |
Time |
17:02 |
Sent To |
E |
|
| Notes |
| 2006-12-16 17:03:01 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2006-11-29 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2006-11-29 |
Time |
17:52 |
Sent To |
E |
|
| Notes |
| 2006-11-29 17:52:45 | REVISION/TO DPALMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-15 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-15 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2006-01-17 00:00:00 | TO "COMM" BD#50 | | 2005-12-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-07 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-07 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2005-10-20 00:00:00 | TO "COMM" BD#20 | | 2005-10-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
2005-07-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-24 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-06-22 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | TO "COMM" BD#49 | | 2005-06-22 00:00:00 | WAITING FOR SPACE ON "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-20 |
Time |
10:04 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2005-07-20 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2005-07-20 00:00:00 | PROVISO: | | | ADDITIONAL PERMIT REQUIRED FOR WALK-IN | | | COOLER.PLEASE PROVIDE MANUFACTURER'S | | | SUBMITTAL DATA WITH PERMIT APPLICATION. | | | | | | PLEASE NOTE, WALK-IN COOLER CANNOT BE | | | INSTALLED PRIOR TO ZONING APPROVAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-24 |
Time |
14:02 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-11-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2005-11-22 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
lshapiro |
Date |
2005-07-14 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
lshapiro |
Date |
2005-07-14 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2005-07-14 00:00:00 | A SITE PLAN HAS NOT BEEN SUBMITTED | | | REFLECTING THE EXPANSION.A MINOR | | | AMENDMENT IS REQUIRED. | | | PURDY CONSTRUCTION WAS CONTACTED ON | | | 07/14/05 AND TOLD A MINOR AMENDMENT IS | | | NEEDED. |
|
|