| 2005-07-27 00:00:00 | DENIED |
| | |
| | 1.SQUARE FOOTAGE ADDED FROM FIRST AND |
| | SECOND FLOOR HAS BEEN REVISED TO |
| | 568SQ.FT.. |
| | |
| | 2.SHOW SPIRAL STAIRCASE DETAIL |
| | COMPLYING WITH FBC 1007.8.2.3 |
| | |
| | 3.ROOF SHEATHING NAILING SHALL COMPLY |
| | WITH FBC 2306.1 WPB AMMENDMENTS. |
| | |
| | 4. 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 5. BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 6. FBC 2304.3.4 WHEN WOOD JOISTS OR THE |
| | BOTTOM OF WOOD STRUCTURAL FLOORS |
| | WITHOUT JOISTS ARE CLOSER THAN 18 |
| | INCHES (457 MM) OR WOOD GIRDERS ARE |
| | CLOSER THAN 12 INCHES (305 MM) TO |
| | EXPOSED GROUND LOCATED WITHIN THE |
| | PERIPHERY OF THE BUILDING OVER CRAWL |
| | SPACE OR UNEXCAVATED AREAS, THEY |
| | SHALL BE OF APPROVED NATURALLY DURABLE |
| | WOOD OR PRESERVATIVE-TREATED WOOD. |
| | |
| | 7. FBC 1804.6.3.2 ACCESS. USABLE CRAWL |
| | SPACES UNDER BUILDINGS WITHOUT |
| | BASEMENTS SHALL BE PROVIDED WITH A |
| | MINIMUM OF ONE ACCESS OPENING NOT |
| | LESS THAN 18X24 INCHES (457X610 MM). |
| | ACCESS OPENINGS SHALL BE READILY |
| | ACCESSIBLE AND PROVIDED WITH A DOOR |
| | OR DEVICE THAT MAY BE EASILY REMOVED |
| | OR OPERATED.FOR ACCESS TO |
| | MECHANICAL EQUIPMENT INSTALLED IN |
| | UNDERFLOOR |
| | AREAS OF THE FLORIDA BUILDING CODE, |
| | MECHANICAL. |
| | |
| | 8.SHOW METHOD AND SIZE OF CRAWL SPACE |
| | VENTILATION COMPLYING WITH FBC |
| | 1804.6.3.1 |
| | |
| | 9. KOLBE DOUBLE HUNG WINDOW DOES NOT |
| | HAVE A STATE APPROVAL SUBMITTED. |
| | PLEASE ATTACH THE FOLLOW STATE PRODUCT |
| | APPROVAL. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 10. SUBMIT PRODUCT APPROVALS FOR |
| | EXTERIOR DOORS AND STRAPS AND TIE-DOWNS. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |