| Plan Review Stops For Permit 05061199 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-04 |
Time |
14:16 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-08-04 |
Time |
14:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-30 |
Time |
11:52 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-06-30 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | SENT TO ZONING BOX W/EMAIL TO MM,GJ,LM | | | AND JW | | 2005-06-21 00:00:00 | PLUMBING PLAN REVIEW PROVISO: | | | FBC 2001 SEC 605.2.1 | | | PURPLE CLEANER FOR PVC PIPE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-03 |
Time |
13:21 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-08-03 |
Time |
13:04 |
Sent To |
B |
|
| Notes |
| 2005-08-03 00:00:00 | NOTES, | | | | | | REVISED RISER DIAGRAM IS FOR REFERENCE | | | ONLY. | | | REVISED RISER WILL STILL NEED TO BE | | | SUBMITTED UNDER BLDG PERMIT FOR | | | CLUBHOUSE AS A REVISION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-08 |
Time |
11:03 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-07-08 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2005-07-08 00:00:00 | ********** UNSAT ********** | | | | | | PLEASE SEE NOTES FROM FIRST REVIEW. | | | | | | 1)NOTE: PLEASE SEE 8 1/2 X 11'S | | | SUBMITTED DO NOT CORRELATE WITH POOL | | | PLANS, PANELS AND EQUIPMENT. | | | PLEASE SEE ONLY ONE FEED IS INDICATED | | | UNDER MAIN BLDG PLAN, WHEREAS TWO PANEL | | | ARE SHOWN ON PLANS. | | | | | | 2)NOTE: PLEASE ALSO SEE PREVIOUS NOTES | | | WITH RESPECT TO LOAD CALCULATIONS. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-29 |
Time |
18:22 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-29 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2005-06-29 00:00:00 | ********* UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE PLASN INDICATE TWO | | | NEW POOL PANELSBEING INSTALLED. | | | PLEASE INDICATE WHERE THESE ARE BEING | | | FED, OCP, FEEDERS, GROUNDING ETC. | | | 215.5 | | | | | | 2)NOTE: PLEASE INDICATE ALL CONTINUOUS | | | LOADS AT 125%. (3 OR MORE HRS) | | | 220, 215.5,215.3,230.42 ETC | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-01 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-01 |
Time |
10:47 |
Sent To |
E |
|
| Notes |
| 2005-08-01 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
15:55 |
Sent To |
E |
|
| Notes |
| 2005-07-06 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-05 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2005-06-22 00:00:00 | TO "COMM" BD#23 | | 2005-06-20 00:00:00 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-21 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-06-21 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2005-06-21 00:00:00 | PLUMBING PLAN REVIEW PROVISO: | | | FBC 2001SEC 605.2.1 | | | PURPLE CLEANER FOR PVC PIPE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-05 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-07-05 |
Time |
15:01 |
Sent To |
PC |
|
| Notes |
| 2005-07-05 00:00:00 | OK PER GRACE JOYCE (PLANS STAMPED) |
|
|