Plan Review Details - Permit 05061170
Plan Review Stops For Permit 05061170
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2005-07-21 Cont ID  
Sent By jhiggins Date 2005-07-21 Time 14:14 Rev Time 0.00
Received By jhiggins Date 2005-07-21 Time 14:14 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status N Date 2005-06-16 Cont ID  
Sent By ptjomsto Date 2005-06-16 Time 14:00 Rev Time 0.00
Received By ptjomsto Date 2005-06-16 Time 14:00 Sent To  
Notes
2005-06-16 00:00:00PCN # NEEDS VERIFICATION/PAPA READS
 74434315170000431 (NO ADDRESS
 ATTACHED)OUR SYSTEM READS
 74434315180000010 (DIFFERENT OWNER)

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-01-19 Cont ID  
Sent By jwitmer Date 2007-01-19 Time 11:29 Rev Time 1.11
Received By jwitmer Date 2007-01-19 Time 11:29 Sent To PC
Notes
2007-01-19 11:29:52REVISION POOL DECK DRAIN

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-30 Cont ID  
Sent By jwitmer Date 2006-03-30 Time 09:08 Rev Time 0.77
Received By jwitmer Date 2006-03-30 Time 09:07 Sent To PC
Notes
2006-03-30 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05061170
 ADD: 1617 N FLAGLER DR
 CONT: STEVE LUCAS AQUATICS
 TEL: (954)461-9007
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVISION REVIEW
 ACTION: DENIED
  
 424.1.3.1.2 POOL WET DECKS SHALL BE
 UNIFORMLY SLOPED AT A MINIMUM
 OF 2 PERCENT TO A MAXIMUM OF 4
 PERCENT AWAY FROM THE POOL OR TO DECK
 DRAINS TO PREVENT STANDING WATER.
 WHEN A CURB IS PROVIDED, THE DECK
 SHALL NOT BE MORE THAN 10 INCHES
 BELOW THE TOP OF THE CURB.
  
 THE PLANS INDICATE THE MARBLE DECK
 CONTINUEING OVER THE DECKO-DRAIN WITH A
 GEO FABRIC BELOW THE MARBLE AND ABOVE
 THE DECKO-DRAIN.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-08-01 Cont ID  
Sent By jwitmer Date 2005-08-01 Time 17:03 Rev Time 0.33
Received By jwitmer Date 2005-08-01 Time 17:03 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2005-08-01 Cont ID  
Sent By btrobaug Date 2005-08-01 Time 16:26 Rev Time 0.25
Received By btrobaug Date 2005-08-01 Time 16:17 Sent To B
Notes
2005-08-01 00:00:00 
 PLEASE SEE ARTICLE 680.26 FOR STEEL
 BONDING REQUIREMENTS.
  
 ALSO NOTE AN ELECTRICAL PERMIT IS
 REQUIRED FOR THIS SCOPE OF WORK.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-01-17 Cont ID  
Sent By adarroug Date 2007-01-17 Time 09:40 Rev Time 0.00
Received By adarroug Date 2007-01-17 Time 09:40 Sent To B
Notes
2007-01-17 09:40:34TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-09 Cont ID  
Sent By adarroug Date 2006-03-09 Time 17:50 Rev Time 0.00
Received By adarroug Date 2006-03-09 Time 17:50 Sent To P
Notes
2006-03-09 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-23 Cont ID  
Sent By adarroug Date 2005-06-23 Time 10:50 Rev Time 0.00
Received By adarroug Date 2005-06-23 Time 10:50 Sent To P
Notes
2005-06-23 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-20 Cont ID  
Sent By shill Date 2005-06-20 Time 13:15 Rev Time 0.00
Received By shill Date 2005-06-20 Time 13:15 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-03-16 Cont ID  
Sent By mperson Date 2006-03-16 Time 10:31 Rev Time 0.33
Received By mperson Date 2006-03-16 Time 10:31 Sent To B
Notes
2006-03-16 00:00:00REVISION:CHANGE IN DECK DRAIN DETAIL

Review Stop P PLUMBING
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pschmitz Date 2005-07-16 Time 06:54 Sent To B
Notes
2005-07-16 00:00:00PLUMBING PLAN REVIEW PROVISO:
 DECO DRAIN TO BE CONNECTED TO STORM
 DRAIN.

Review Stop Z ZONING
Rev No 1 Status N Date 2005-06-22 Cont ID  
Sent By mmclean Date 2005-06-22 Time 18:00 Rev Time 0.00
Received By mmclean Date 2005-06-22 Time 18:00 Sent To I
Notes
2005-06-22 00:00:00DOES NOT REQUIRED ZONING REVIEW, FOOT-
 PRINT OF EXISTING POOL STRUCTURE


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved