Plan Review Details - Permit 05061162
Plan Review Stops For Permit 05061162
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-06-30 Cont ID  
Sent By jwitmer Date 2005-06-30 Time 11:52 Rev Time 0.00
Received By jwitmer Date 2005-06-30 Time 11:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-30 Cont ID  
Sent By dpalmer Date 2006-03-30 Time 07:33 Rev Time 0.00
Received By dpalmer Date 2006-03-30 Time 07:21 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-03-18 Cont ID  
Sent By dpalmer Date 2006-03-18 Time 19:11 Rev Time 0.00
Received By dpalmer Date 2006-03-18 Time 19:10 Sent To PC
Notes
2006-03-18 00:00:00********* UNSAT ************
  
 1)NOTE: PLEASE HAVE ENGINEER SIGN PLANS
 WITH SIGNATURE AS ON CITY SIGNATURE FILE
 PER FS 471.025
  
 2)NOTE: PLEASE CLARIFY METER, AS IT
 SEEMS IT MAY BE A METER/MAIN COMBO PANEL
 DUE TO THE NUMBER OF CONDUCTORS SHOWN.
 IF THIS IS ONLY A METER, PLEASE COMPLETE
 PAHSE CONDUCTORS, AND NEUTRALS TO THE
 FIRST MEANS OF DISCONNECT. PLEASE KNOW,
 NO "EQUIPMENT GROUNDING CONDUCTORS" ARE
 INSTALLED BEFORE THR FIRST MEANS OF
 DISCONNECT. PER 250.6,250.24
 EVEN IF THE ONLY LOADS BEING SERVED ARE
 MOTOR LOADS, A NEUTRAL MUST BE RBOUGHT O
 THE FIRST MEANS.
 IF INDEED THIS IS A METER/MAIN PANEL,
 PLEASE PROVIDE OCP FOR EACH FEEDER.
 240.4,310.16 ETC
 215.5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-06-27 Cont ID  
Sent By dpalmer Date 2005-06-27 Time 08:54 Rev Time 0.25
Received By dpalmer Date 2005-06-27 Time 08:54 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2005-06-30 Cont ID  
Sent By jwitmer Date 2005-06-30 Time 11:52 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-06-28 Cont ID  
Sent By mwennerg Date 2005-06-28 Time 15:20 Rev Time 0.00
Received By mwennerg Date 2005-06-28 Time 15:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-29 Cont ID  
Sent By adarroug Date 2006-03-29 Time 14:19 Rev Time 0.00
Received By adarroug Date 2006-03-29 Time 14:19 Sent To E
Notes
2006-03-29 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-15 Cont ID  
Sent By adarroug Date 2006-03-15 Time 15:12 Rev Time 0.00
Received By adarroug Date 2006-03-15 Time 15:12 Sent To E
Notes
2006-03-15 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-17 Cont ID  
Sent By shill Date 2005-06-30 Time 11:52 Rev Time 0.00
Received By jwitmer Date 2005-06-17 Time 09:24 Sent To  
Notes
2005-06-21 00:00:00TO "COMM" BD#27
2005-06-17 00:00:00WAITING FOR COMM BOARD
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-06-30 Cont ID  
Sent By jwitmer Date 2005-06-30 Time 11:51 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-06-30 Cont ID  
Sent By jwitmer Date 2005-06-30 Time 11:51 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-06-27 Cont ID  
Sent By jlong Date 2005-06-27 Time 14:37 Rev Time 0.00
Received By jlong Date 2005-06-27 Time 14:37 Sent To  
Notes
***NONE***