| Plan Review Stops For Permit 05061017 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-05-08 |
Time |
08:19 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2006-05-08 |
Time |
08:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-14 |
Time |
06:22 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-09-13 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-24 |
Time |
12:55 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-07-24 |
Time |
12:55 |
Sent To |
PC |
|
| Notes |
| 2005-07-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05061017 | | | ADD: 2813 EXCHANGE CT | | | CONT: SOUTHHAMPTON RESTORATION | | | TEL: (561)687-0505 | | | | | | 2001 FL BLDGFLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) MULLION | | | | | | 3) PLANS DO NOT PROVIDE CLASSIFICATION | | | BY TYPE OF BUILDING 601.2.1. PLANS ALSO | | | DO NOT PROVIDE IF FIRE SPRINKLERED? A-3 | | | INDICATES A FIRE SPRINKLER RISER ON THE | | | EXTERIOR OF BUILDING, IS ACTIVE? | | | | | | 4) PROVIDE INFORMATION ON CHAIRLIFT? | | | TO COMPLY WITH ASME A 17.1. | | | | | | 5) IF BUILDING IS NOT FIRE SPRINKLERED, | | | THEN ARTICLES DEALING WITH AREA OF | | | RESCUE ASSISTANCE ARE REQUIRED. | | | SEE 11-4.3.11.1.(1-7). | | | | | | 6)SEE A.1 LUNCHROOM INDICATES SECTION 3 | | | BUT NO SECTION APPEARS FOR LUNCH COUNTER | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER NO HIGHER THAN | | | 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARENCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | | | | 7)M1 INDICATES A A/C GRILL IN THE | | | STAIRWELL, SEE 1006.1.3.1. | | | | | | 8) DOOR# 9 REQUIES 18" CLEAR ON THE | | | LATCH SIDE. 11-4.13.6 MANEUVERING | | | CLEARENCES AT DOORS. MINIMUM MANEUVERING | | | CLEARENCES AT DOORS THAT ARE NOT | | | AUTOMATIC OR POWER-ASSISTED SHALL BE AS | | | SHOWN IN FIG. 25. THE FLOOR OR GROUND | | | AREA WITH IN THE REQUIRED CLEARENCES | | | SHALL BE CLEAR & LEVEL. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-22 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-22 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2006-06-22 00:00:00 | ** PLANS REDLINED ** | | | | | | TO VERIFY OF PC/ MPDEM RM IS INDEED AN | | | "IT" ROOM WHICH WILL REQUIRE RATING S | | | FOR CONSTRUCTION, DISCONNECTS ETC. | | | PLEASE SEE 645 OF NFPA-70, AND NFPA-75 | | | FOR REQUIREMENTS ALSO IN "IT" ROOMS. | | | ENGINEER OR RECORD HAS SEALED PLANS NOT | | | AS AN IT ROOM. | | | | | | | | | ** PLEASE KNOW, AS NOTED ON PREVIOUS | | | REVIEW, THIS ROOM WAS NOT ON ORIGINAL | | | PLANS AND WAS ADDED DURING CONSTRUCTION. | | | IF AN "IT", REVISED PLANS WILL BE | | | REQUIRED TO BE SUBMITTED FOR B,M,F, E. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-25 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-25 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2006-04-25 00:00:00 | ************UNSAT *************** | | | | | | 1) NOTE: PLEASE SEE PLANS WHICH WERE | | | REDLINED TWICE BEFORE THIS REVIEW WHICH | | | REQUESTED KITCHENS IN OTHER THAN | | | DWELLING UNITS TO MEET 210.8B3 | | | PLEASE ADJUST. | | | | | | 2) NOTE: PLEASE PROVIDE ALL ROOM AND | | | AREA DESIGNATIONS ON PLANS. | | | PLEASE SEE AN "IT" ROOM WAS NOT | | | IDENTIFIED ON ORIG ELECTRICAL PLANS. | | | PLEASE SEE ALL OF NEC 645, NFPA-75 FOR | | | MIN REQUIRMENTS. | | | PLEASE SEE 645.10,645.5,645.2. | | | PLEASE ADJUST ACCORDINGLY. | | | | | | 3) NOTE: PLEASE SEE RISER WHICH INDICATE | | | ONE RISER OF 3-3/0'S OR 500MCM'S, WHICH | | | IS ALSO NOTED AS BEING DONE BY FPL, OR | | | MAYBE BY FPL. | | | PLEASE KNOW, THE WH, RISER, ETC UP TO | | | THE SERVICE ENTRANCE DRIP LOOP BELONGS | | | TO THE OWNER OF THE BUILDING, NOT FPL. | | | FPL WILL NOT BE INSTALLING THIS RISER. | | | PLEASE SPECIFY WHICH OPTION FOR RISER | | | WAS OR IS BEING INSTALLED. | | | THIS WAS REDLINED ON PREVIOUS PLANS. | | | 215.5. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-09-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-03 |
Time |
20:19 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-09-03 |
Time |
20:10 |
Sent To |
|
|
| Notes |
| 2005-09-03 00:00:00 | ********* NOTES REDLINED ********* | | | | | | 1)NOTE: PLEASE SEE PREVIOUS REVIEW, | | | PLANS WERE REDLINED FOR 2002 NEC 210.8B3 | | | WHICH REQUIRES ALL 15A& 20A RECEPTS IN | | | KITCHEN/LUNCH RM AREA TO BE GFI OR GFI | | | PROTECTED CIRCUITS. | | | | | | THIS WAS RED LINED PLANS ONCE AGAIN. | | | PLEASE KNOW, IF PLANS COME BACK DURING | | | CONTRUCTION FOR ANY OTHER REVISIONS, | | | PLEASE MAKE CORRECTIONS. | | | | | | NEW SHEETS E-1 AND E-2 SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-01 |
Time |
15:35 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-07-01 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | **** REDLINED PLANS ********** | | | | | | | | | | | | PLEASE SEE 2002 NEC 210.8B3 WHICH | | | REQUIRES ALL 15- AND 20-AMPERE, 125-VOLT | | | RECEPTACLES IN NONDWELLING-TYPE KITCHENS | | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | | APPLIES TO EACH AND EVERY 15- AND | | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | | WHETHER OR NOT THE RECEPTACLE SERVES | | | COUNTERTOP APPLIANCES. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-02 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-02 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-09-12 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-09-12 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2005-09-12 00:00:00 | 1. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-07-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-07-11 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2005-07-11 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM THE | | | SITE DAILY. | | | | | | 3. ON PAGE M1 THERE APPEARS TO BE A/C | | | DUCTWORK WITHIN THE EXIT STAIR. IF SO, | | | NOT ALLOWED BY CODE. PLEASE EXPLAIN. | | | | | | 4. PLEASE PROVIDE PRESCRIPTIVE STRENGTH | | | REQUIREMENTS FOR HANDRAILS. | | | | | | 5. TEN (10) INCH TREADS SHOWN ON PAGE | | | A-4. TEN INCH TREADS ARE NOT ALLOWED | | | FOR NEW STAIRS. | | | | | | 6. FIRE ALARM SYSTEM SHALL BE CLASS A OR | | | FULLY ADDRESSABLE. | | | | | | 7. ELEVATION DRAWINGS DO NOT DISPLAY | | | BUILDING ADDRESS. BUILDING ADDRESS SHALL | | | BE A MINIMUM OF AT LEAST 6" HIGH | | | NUMBERS. | | | | | | 8. WHAT FIRE RATING IS PRESENT FOR THE | | | STAIRWELL DOOR LOCATED ON THE SECOND | | | LEVEL NEAR FAX PRINTER AREA. | | | | | | 9. PLEASE ILLUSTRATE FIRE EXTINGUISHER | | | LOCATIONS. | | | | | | 10. PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER. | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-08 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-08 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2006-06-22 00:00:00 | TO "COMM" BD#4-REV | | 2006-06-08 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-28 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-28 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | 6/2/06-FROM "COMM" BD#26-ROUTED TO "F" | | 2006-04-18 00:00:00 | TO "COMM" BD#26 | | 2006-03-28 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-18 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-18 |
Time |
10:09 |
Sent To |
P |
|
| Notes |
| 2005-10-18 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-25 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-25 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | TO "COMM" BD#53 | | 2005-08-25 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-24 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-06-14 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2005-06-20 00:00:00 | COMM BOARD #48 | | | | | 2005-06-14 00:00:00 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-08 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-08 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2006-08-08 00:00:00 | EQUIPMENT SCHEDULE / EQUIPMENT CHANGE | | | FROM CARRIER TO TRANE / 13 SEER |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-05 |
Time |
12:12 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-07-05 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2006-07-05 00:00:00 | REVISION TO MECH. PLANS PAGE M1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-10 |
Time |
10:21 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-05-10 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2006-05-10 00:00:00 | *** PROVISO *** | | | 1) BATHROOM EXHAUST APPEARS TO TERMINATE | | | BELOW THE FRESH AIR INTAKE TO AHU#1, | | | PLEASE COMPLY WITH 2001 FBC/M 501.3 . | | | 2) BATHROOM EXHAUST FANS REQUIRE 100 | | | CFM'S EACH. NEED 50 CFM,S PER WATER | | | CLOSET OR URINAL, PER 2001 FBC/M 403.3 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-11-21 |
Time |
14:10 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-11-21 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | PROVISO: | | | 1. PLAN SHEET M-1 PER 2001 FBC(M)501.3, | | | EXHAUST SHALL TERMINATE AT A LOCATION AS | | | NOT TO BE READILY DRAWN IN BY THE | | | VENTILATING SYSTEM.EXHAUST TERMINATION | | | APPEAR TO TERMINATE UNDERNEATH THE FRESH | | | AIR INTAKE TO AHU-1.PLEASE REVISE | | | PLANS PRIOR TO INSPECTION. | | | | | | 2. FAN SHUTDOWN REQUIRED FOR AHU-1 PER | | | 2001 FBC(M)606.2.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-20 |
Time |
06:48 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-07-20 |
Time |
06:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-26 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-26 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2006-07-26 00:00:00 | AS BUILT FOR PLUMBING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-06-01 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-05-31 |
Time |
19:27 |
Sent To |
|
|
| Notes |
| 2006-06-01 00:00:00 | REVISION OK - SHTS P-1 & P-3. - SHTS P-2 | | | & P-4 NO REVISIONS NOTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-21 |
Time |
13:41 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-11-21 |
Time |
13:41 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-18 |
Time |
13:22 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-10-18 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2005-10-18 00:00:00 | DENIED; | | | 1. PLEASE SHOW TURNING RADIUS IN LADIES | | | TOILET ROOM. (THIRD REQUEST) | | | 2.WOMAN'S ROOM TOILET STALL IS TO SMALL. | | | REQUIRED TO BE 30" X 60" SEE FBC-2001 | | | PLUMBING SEC. 405.3.1 AND FIG. 405.3.1. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-10-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-01 |
Time |
14:01 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-10-01 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2005-10-01 00:00:00 | DENIED; | | | 1. SHEET D-1 ADD TO NOTES DEAD ENDS TO | | | BE 2' OR LESS, FIELD INSPECTION | | | REQUIRED. | | | 2.WOMEN'S ROOM; SHOW THE CLEAR FLOOR | | | SPACE FOR THE TOILET ROOM IN THE TOILET | | | ROOM NOT IN THE STALL. | | | 3.BREAK SINK DOES NOT COMPLY WITH FBC | | | CHAPTER 11 SEC. 11-4.24.3 KNEE CLEARANCE | | | SHALL BE 19" UNDERNEATH SINK. LOWER | | | FRONT PANEL CAN NOT BE INSTALLED AS | | | DRAWN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-12 |
Time |
08:21 |
Rev Time |
1.12 |
| Received By |
kstevens |
Date |
2005-07-12 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1. SHT D-1 IN THE REMOVAL OF ANY PART OF | | | A DRAINAGE SYSTEM, DEAD ENDS SHALL BE | | | PROHIBITED. SECTION 704.5 - ALL CAPPED | | | OFF PIPING SHALL BE FIELD INSPECTED | | | PRIOR TO COVERING. | | | 2. SHT A-1 SHOW CLEAR FLOOR SPACE FOR | | | THE SINK IN THE LUNCHROOM. SECTION | | | 11-4.24.5. SINK SHALL BE CENTERED ON THE | | | 30" WIDTH. | | | 3. SHT A-1 SHOW THE CLEAR FLOOR SPACE | | | FOR THE TOILET ROOMS IN THE TOILET ROOM, | | | NOT THE STALL. SECTION 11-4.22.3 | | | 4. SHT A-5 BREAKROOM SINK SHALL BE | | | ACCESSIBLE. PROVIDE THE FOLLOWING | | | INFORMATION ON DETAIL 3/A5 TO SHOW | | | COMPLIANCE: | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.5 CLEAR FLOOR SPACE SHALL BE | | | PROVIDED TO ALLOW FORWARD APPROACH AND | | | SHALL EXTEND A MAXIMUM OF 19" UNDERNEATH | | | THE SINK. - CABINET DOORS SHALL NOT BE | | | IN THE CLEAR FLOOR SPACE. | | | E. 11-4.24.6 EXPOSED PIPES & SURFACES | | | F. 11-4.24.7 FAUCETS | | | 5. SHT P2 WATER RISER DIAGRAM, AIR | | | CHAMBERS ARE NOT APPROVED, DELETE FROM | | | RISER DIAGRAM. SECTION 604.9. - WATER | | | HAMMER ARRESTORS SHALL BE LOCATED NEAR | | | THE FIXTURES IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|