Plan Review Details - Permit 05060988
| Plan Review Stops For Permit 05060988 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-18 |
Time |
16:04 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-18 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)THE FLORIDA STATE PRODUCT APPROVAL | | | DOES NOT MATCH THE NOAS SUBMITTED | | | (JELD-WEN DOOR). | | | | | | 2.)PRODUCT APPROVALS FOR GLASS BLOCK | | | AND SLIDING GLASS DOORS WERE SUBMITTED. | | | NEITHER ARE SHOWN ON THE FLOOR PLAN. | | | | | | 3.)EMERGENCY EGRESS REQUIRED FOR | | | BEDROOMS, FBC1005.4.SHOW WINDOW TYPE | | | AND SIZE. | | | | | | 4.)SUBMIT PRODUCT APPROVALS FOR | | | MULLIONS AND WINDOWS. | | | | | | 5.)IF THE WINDOWS ARE NOT IMPACT, | | | IMPACT PROTECTION REQUIRED FBC1606.1.4. | | | | | | 6.)THREE DIFFERENT NOAS ARE CONTAINED | | | IN THE JELD-WEN BROCHURE.PLEASE SUBMIT | | | ONLY THE DOOR WHICH YOU ARE INSTALLING. | | | | | | 7.)ON EACH PRODUCT APPROVAL INDICATE | | | WHICH METHOD OF ATTACHMENT YOU ARE USING | | | SO THAT CODE COMPLIANCE CAN BE | | | DETERMINED. | | | | | | 8.)THE NOTICE OF COMMENCEMENT DOES NOT | | | REFLECT THE INSTALLATION OF DOORS AND | | | WINDOWS, FS713.13. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-02 |
Time |
15:14 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-02 |
Time |
15:14 |
Sent To |
PC |
|
| Notes |
| 2005-07-02 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED IN ADDITION TO THE | | | EVALUATION REPORTS (NOAS) PROVIDED. | | | WWW.FLORIDABUILDING.ORG | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)IMPACT PROTECTION REQUIRED | | | FBC1606.1.4. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-30 |
Time |
09:23 |
Rev Time |
0.30 |
| Received By |
btrobaug |
Date |
2005-06-30 |
Time |
09:22 |
Sent To |
B |
|
| Notes |
| 2005-06-30 00:00:00 | | | | NO ELECTRICAL PLANS SUBMITTED FOR | | | REVIEW./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-14 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-14 |
Time |
14:10 |
Sent To |
B |
|
| Notes |
| 2005-07-14 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-16 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-16 |
Time |
09:27 |
Sent To |
E |
|
| Notes |
| 2005-06-16 00:00:00 | TO 'E' BOX. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |