| Plan Review Stops For Permit 05060925 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-13 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2006-02-05 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-06 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-09-06 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2005-09-06 00:00:00 | NEEDS TO PAY IMPACT FEES AND HAVE PLANS | | | STAMPED BY THE COUNTY BEFORE THE PERMIT | | | IS ISSUED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-23 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-23 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2005-08-23 00:00:00 | DENIED | | | | | | 1) PLEASE REVISE THE ANCHOR SCHEDULE ON | | | A5. THE MAXIMUM UPLIFT FOR A USP HTA 16 | | | CONNECTOR IS 1500#. THE DOUBLE HTA 16 | | | HAS A MAXIMUM UPLIFT OF 3000#. THESE ARE | | | THE VALUES LISTED IN THE 2005 USP | | | CATALOG AND DO NOT INCLUDE THE ONE THIRD | | | STRESS INCREASE ON THE STEEL | | | CALCULATIONS WHICH IS NOT ALLOWED BY THE | | | 2001 FBC. SEE FBC 1609.4.3. SEE ITEM #6 | | | ON PREVIOUS REVIEW. | | | | | | 2) THE DESIGN PRESSURES REQUIRED BY THE | | | PLANS FOR THE SMALL GARAGE DOOR EXCEED | | | THE DESIGN PRESSURES GIVEN IN THE | | | PRODUCT APPROVAL THAT WAS SUBMITTED. | | | SUBMIT PRODUCT WITH ADEQUATE DESIGN | | | PRESSURES. SEE COMMENT # 8 FROM PREVIOUS | | | REVIEW. | | | | | | 3) THE PRODUCT APPROVALS SUBMITTED FOR | | | THE FIXED GLASS WINDOWS ARE FOR | | | NON-IMPACT RESISTANT GLAZING. THE PLANS | | | SPECIFY IMPACT GLAZING FOR ALL WINDOWS. | | | SUBMIT PRODUCT APPROVALS FOR IMPACT | | | WINDOWS OR REVISE PLANS AND SUBMIT STORM | | | PANEL PRODUCT APPROVALS, KEY PLANS AND | | | INSTALLATION SCHEDULES. | | | | | | 4)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-15 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-07-15 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2005-07-15 00:00:00 | DENIED | | | | | | 1)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) ITEM #4 IN THE DOOR SCHEDULE ON A2 IS | | | LISTED AS A SLIDING GLASS DOOR AND ON | | | THE PLAN IT IS DRAWN AS A DOUBLE | | | OUTSWING FRENCH DOOR AT THE FAMILY ROOM. | | | | | | 3) ITEM #16 IN THE SCHEDULE IS ANOTHER | | | SLIDING GLASS DOOR AND THERE AREN'T ANY | | | SG DOORS ON THE PLANS. PLEASE CORRECT. | | | ALSO REMOVE THE PRODUCT APPROVALS FOR | | | SLIDING GLASS DOORS FROM THE SUBMITTALS | | | AS IT DOES NOT APPLY TO THIS PROJECT. | | | | | | 4) PLEASE UPDATE DESIGN CRITERIA ON A5. | | | THE REFERENCED STANDARDS IN THE 2OO1 FBC | | | ARE ACI 318-02 AND ACI530.1-02. SEE FBC | | | CHAPTER 35. | | | | | | 5) ON A5 THERE IS A CONNECTOR AT THE | | | COVERED PATIO WITH A #12 TAG. THERE IS | | | NO #12 SPECIFIED IN THE ANCHOR LEGEND. | | | PLEASE CLARIFY. | | | | | | 6) PLEASE REVISE THE ANCHOR SCHEDULE ON | | | A5, AS SEVERAL CONNECTOR UPLIFTS | | | SPECIFIED ARE IN ERROR. THE MAXIMUM | | | UPLIFT FOR HTA 16 IS 1500#. THE DOUBLE | | | HTA 16S HAVE A MAXIMUM UPLIFT OF 3000#. | | | THE MAX. UPLIFTS FOR THE 'USP' RT22T AND | | | RT20T ARE 1225#. SEE 2005 USP CATALOG. | | | | | | 7) PROVIDE STRUCTURAL DETAILS OF THE | | | CUPOLA ABOVE THE MASTER BEDROOM. SPECIFY | | | ALL CONNECTORS, EXTERIOR AND INTERIOR | | | FINISHES, STUD SIZE AND SPACING, | | | INSULATION, ETC. | | | | | | 8) THE DESIGN PRESSURES REQUIRED BY THE | | | PLANS FOR THE SMALL GARAGE DOOR EXCEED | | | THE DESIGN PRESSURES GIVEN IN THE | | | PRODUCT APPROVAL THAT WAS SUBMITTED. | | | | | | 9) SUBMIT PRODUCT APPROVALS FOR THE | | | HOLLOW METAL DOOR AT THE MECHANICAL | | | ROOM, # 17 IN THE SCHEDULE. | | | | | | 10) SUBMIT PRODUCT APPROVALS FOR THE | | | STORE FRONT WINDOWS (H,I,AND D IN THE | | | SCHEDULE). | | | | | | 11) ITEM #5 IN THE DOOR SCHEDULE IS | | | SPECIFIED AS A STORE DOOR. PLEASE | | | CLARIFY AND SUBMIT THE APPROPRIATE | | | PRODUCT APPROVAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-02-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-02-05 |
Time |
11:14 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-02-05 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-18 |
Time |
08:01 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-18 |
Time |
07:37 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-22 |
Time |
18:17 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-22 |
Time |
18:00 |
Sent To |
M |
|
| Notes |
| 2005-06-22 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE RISER SHOWS PANELS WITH MAIN | | | BREAKERS, PLAN SHOWS MAIN DISCONNECTS | | | OUTSIDE AND PANELS INSIDE. PLEASE | | | CLARIFY. | | | | | | 2} PANEL "C" IS FED FROM PANEL "B" ON | | | THE RISER, BUT OUT OF PANEL "A"ON THE | | | SCHEDULE. | | | | | | 3} INDICATE THE AIC RATING OF THE | | | SERVICE EQUIPMENT PER 110.9 & 10. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-29 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-29 |
Time |
16:26 |
Sent To |
B |
|
| Notes |
| 2005-08-29 00:00:00 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-16 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-16 |
Time |
09:15 |
Sent To |
E |
|
| Notes |
| 2005-08-16 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-09 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-09 |
Time |
14:38 |
Sent To |
Z |
|
| Notes |
| 2005-08-09 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-22 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-22 |
Time |
13:28 |
Sent To |
E |
|
| Notes |
| 2005-06-22 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-14 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-14 |
Time |
06:45 |
Sent To |
Z |
|
| Notes |
| 2005-06-14 00:00:00 | TO 'Z' BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-22 |
Time |
06:32 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-08-22 |
Time |
06:32 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-05 |
Time |
12:12 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-07-05 |
Time |
11:50 |
Sent To |
B |
|
| Notes |
| 2005-07-05 00:00:00 | DENIED: | | | 1.PROVIDE COMBUSTION AIR CALCULATIONS | | | ON THE LAUNDRY ROOM WITH THE GAS DRYER | | | IN ACCORDANCE WITH 2001 FBC(M) CHAPTER | | | 7. | | | | | | 2.PER 2001 FBC CHAPTER 13 SUB-SECTION | | | 609.1.ABC.1 #2, NO VENTILATION OR A/C | | | MAKE-UP AIR SHALL BE PROVIDED TO | | | CONDITIONED SPACE FROM ATTICS OR | | | ROOFTOPS.LAUNDRY ROOM INDICATES VTR | | | BUT DOES NOT INDICATE IF THIS IS FOR THE | | | COMBUSTION AIR MAKE-UP, PLEASE CLARIFY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-27 |
Time |
14:04 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-25 |
Time |
06:23 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-11 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-11 |
Time |
18:38 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-21 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-21 |
Time |
14:33 |
Sent To |
I |
|
| Notes |
| 2005-06-21 00:00:00 | DENIED, | | | 1. MUST REMOVE THE GAS COOKTOP FROM | | | PLANS - OUTSIDE BALLARD ROOM.(ONLY ONE | | | COOKING FACILITY IS ALLOWED IN SF7). | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|