Plan Review Details - Permit 05060776
Plan Review Stops For Permit 05060776
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2006-03-20 Cont ID  
Sent By shill Date 2006-03-20 Time 15:58 Rev Time 0.00
Received By shill Date 2006-03-20 Time 15:58 Sent To  
Notes
2006-03-20 00:00:00DOOR PRODUCT APPROVAL
 FG PRODUCT APPROVAL
 REVISED SHEETS 1 AND 1A

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2006-02-21 Cont ID  
Sent By shill Date 2006-02-21 Time 16:22 Rev Time 0.00
Received By shill Date 2006-02-21 Time 16:22 Sent To Z
Notes
2006-02-21 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED IN ADDITION TO THE
 NOAS SUBMITTED, FAC9B72.
 WWW.FLORIDABUILDING.ORG
  
 2.)CASEMENT WINDOW PRODUCT APPROVALS
 SUBMITTED; PLANS SHOW A FIXED GLASS
 WINDOW.
  
 3.)SHOW THE ACCESSIBLE ROUTE FROM THE
 NEW ACCESSIBLE PARKING TO THE ENTRANCE,
 11-4.1.2(1).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2006-02-17 Cont ID  
Sent By shill Date 2006-02-17 Time 10:00 Rev Time 0.00
Received By shill Date 2006-02-17 Time 09:14 Sent To  
Notes
2006-02-17 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)SEE PLUMBING COMMENTS.DETAIL
 PROVIDED CONFLICTS WITH AS BUILT
 CONDITIONS.
  
 2.)THIS PERMIT WAS ISSUED WITH A
 PROVISO THAT THE DOORS AND WINDOWS WERE
 TO BE ON A SEPARATE PERMIT AS THE
 PRODUCT APPROVALS WERE NOT SUBMITTED
 DURING PLAN REVIEW.THIS WAS DONE AS A
 COURTESY TO I HAVE NOT FOUND A
 RECORD OF THIS PERMIT; PLEASE APPLY OR
 PROVIDE ME WITH THE PERMIT NUMBER.
  
 3.)SHOW COMPLIANCE WITH
 FBC11-4.1.6(2) AS DISCUSSED WITH
 ARCHITECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status   Date 2006-02-16 Cont ID  
Sent By tadams Date 2006-02-16 Time 15:31 Rev Time 0.00
Received By tadams Date 2006-02-16 Time 15:30 Sent To B
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-09-22 Cont ID  
Sent By shill Date 2005-09-22 Time 23:59 Rev Time 0.00
Received By shill Date 2005-09-22 Time 23:59 Sent To  
Notes
2005-09-22 00:00:00REVISION, ALTERNATE INFILL DETAIL

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-08-16 Cont ID  
Sent By shill Date 2005-08-10 Time 18:48 Rev Time 1.00
Received By shill Date 2005-08-10 Time 18:48 Sent To  
Notes
2005-08-10 00:00:00***PROVISO***
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEPARATE PERMITS ARE REQUIRED FOR
 THE DOORS & WINDOWS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-24 Cont ID  
Sent By shill Date 2005-07-24 Time 13:27 Rev Time 2.00
Received By shill Date 2005-07-24 Time 00:37 Sent To  
Notes
2005-07-24 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)PROVIDE A SURVEY AND SITE PLAN.
  
 3.)THE TITLE BLOCK IS REQUIRED TO
 INCLUDE THE FIRM LICENSE NUMBER (FOR
 ROBERT L BELL ARCHITECT PA) AND PRINTED
 NAME OF THE PERSON WHO HAS SEALED THE
 DOCUMENT, FAC61G1-16.003,004.
  
 4.)A TYPE IV FOR THIS BUILDING IS
 DECLARED ON SHEET 1.THIS IS IN
 CONFLICT WITH DETAIL 1-3 WHICH SHOWS A
 METAL FRAME WALL WITH PLYWOOD SHEATHING
 AND DETAILS FOR THE PARAPET WALL WHICH
 ALSO SHOW PLYWOOD SHEATHING.NOTE THAT
 TYPE VI CONSTRUCTION IS NOT ALLOWED IN
 THE FIRE DISTRICT, FBC*F102.1.
  
 5.)SHOW TURNING CLEARANCE FOR THE
 BATHROOMS, FBC11-4.22.3.
  
 6.)THE ENERGY CALCS SUBMITTED APPEAR
 TO BE FOR THE TWO DIFFERENT TENANT
 SPACES, BUT BOTH HAVE 2800 AS THE SQUARE
 FOOTAGE.THIS IS THE TOTAL FOR THE
 ENTIRE BUILDING, NOT THE TENANT SPACES.
 CLARIFY.
  
 8.)FBC1503.4.4, CONDENSATE LINES AND
 ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST
 1 FOOT (305 MM) AWAY FROM THE STRUCTURE
 SIDEWALL, WHETHER BY UNDERGROUND PIPING,
 TAIL EXTENSIONS, OR SPLASH BLOCKS.NOTE
 THE 1? DIMENSION ON THE PLAN, SHEET 2.
  
 9.)FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED IN ADDITION TO THE
 FIXED GLASS NOA PROVIDED.
  
 10.)IN ADDITION TO THE FIXED GLASS
 WINDOW, PROVIDE PRODUCT APPROVALS FOR
 THE FRENCH DOORS AND THE HOLLOW METAL
 DOOR.ANY PRODUCT APPROVALS NOT
 SUBMITTED AND REVIEWED PRIOR TO PERMIT
 ISSUANCE WILL REQUIRE SEPARATE PERMITS.
  
 11.)SEE ATTACHED POLICY IN REGARDS TO
 IMPACT PROTECTION, ITEM #13.BE ADVISED
 THAT ALL GLAZING IS TO BE IMPACT UNLESS
 APPROVED BY THE BUILDING OFFICIAL.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-06-27 Cont ID  
Sent By dpalmer Date 2005-06-27 Time 14:28 Rev Time 0.50
Received By dpalmer Date 2005-06-27 Time 14:28 Sent To  
Notes
2005-06-27 00:00:00** NOTES REDLINED ON PLANS **
  
 MISSING SIGN CIRCUITS FOR BOTH TENANTS
 PER 600.5
  
 SEE 210.8B3 FOR ALL RECEPTS IN KITCHEN.
 (2002 NEC )
  
 SEE 2 GRNDS ROODS REQUIRED. 250.50

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-07-01 Cont ID  
Sent By mwennerg Date 2005-07-01 Time 10:54 Rev Time 0.00
Received By mwennerg Date 2005-07-01 Time 10:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-03-07 Cont ID  
Sent By adarroug Date 2006-03-07 Time 14:59 Rev Time 0.00
Received By adarroug Date 2006-03-07 Time 14:59 Sent To  
Notes
2006-03-07 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-02-03 Cont ID  
Sent By adarroug Date 2006-02-03 Time 11:34 Rev Time 0.00
Received By adarroug Date 2006-02-03 Time 11:34 Sent To M
Notes
2006-02-03 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-12-02 Cont ID  
Sent By adarroug Date 2005-12-02 Time 15:53 Rev Time 0.00
Received By adarroug Date 2005-12-02 Time 15:53 Sent To M
Notes
2005-12-02 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-21 Cont ID  
Sent By adarroug Date 2005-09-21 Time 14:29 Rev Time 0.00
Received By adarroug Date 2005-09-21 Time 14:29 Sent To B
Notes
2005-09-21 00:00:00TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-28 Cont ID  
Sent By adarroug Date 2005-07-28 Time 13:50 Rev Time 0.00
Received By adarroug Date 2005-07-28 Time 13:50 Sent To  
Notes
2005-08-02 00:00:00TO "COMM" BD#12
2005-07-28 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-24 Cont ID  
Sent By shill Date 2005-07-24 Time 13:28 Rev Time 0.00
Received By shill Date 2005-06-10 Time 10:39 Sent To  
Notes
2005-06-16 00:00:00COMM BOARD #28
2005-06-10 00:00:00WAITING FOR COMM BOARD

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-02-03 Cont ID  
Sent By tgordon Date 2006-02-03 Time 15:46 Rev Time 0.20
Received By tgordon Date 2006-02-03 Time 15:46 Sent To  
Notes
2006-02-03 00:00:00REV. TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-01-26 Cont ID  
Sent By pkrauss Date 2006-01-26 Time 14:46 Rev Time 0.00
Received By pkrauss Date 2006-01-26 Time 14:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-12-05 Cont ID  
Sent By tgordon Date 2005-12-05 Time 12:14 Rev Time 0.25
Received By tgordon Date 2005-12-05 Time 12:14 Sent To  
Notes
2005-12-05 00:00:00MECH. REV. TO PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-13 Cont ID  
Sent By hmoser Date 2005-07-13 Time 17:47 Rev Time 0.00
Received By hmoser Date 2005-07-13 Time 17:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2006-03-18 Cont ID  
Sent By pschmitz Date 2006-03-18 Time 09:26 Rev Time 0.00
Received By pschmitz Date 2006-03-18 Time 09:26 Sent To  
Notes
2006-03-18 00:00:00DETAIL REMOVED

Review Stop P PLUMBING
Rev No 4 Status F Date 2006-02-22 Cont ID  
Sent By jleech Date 2006-02-22 Time 09:06 Rev Time 0.50
Received By jleech Date 2006-02-22 Time 08:49 Sent To B
Notes
2006-02-22 00:00:00DENIED;
 SECOND REQUEST; REMOVE "TOILET ROOM"
 DETAIL ON SHEET 1-A. REMOVE, REMOVE,
 REMOVE
 ---------------------

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-02-17 Cont ID  
Sent By jleech Date 2006-02-17 Time 08:10 Rev Time 0.33
Received By jleech Date 2006-02-17 Time 08:10 Sent To B
Notes
2006-02-17 00:00:00DENIED;
 PLEASE REMOVE "TOILET ROOM CLEARANCE"
 DETAIL. BATHROOMS ARE NOT THE SIZE SHOWN
 IN DETAIL.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-13 Cont ID  
Sent By pschmitz Date 2005-08-13 Time 14:39 Rev Time 0.00
Received By pschmitz Date 2005-08-13 Time 14:39 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-07-07 Cont ID  
Sent By kstevens Date 2005-07-07 Time 13:02 Rev Time 1.25
Received By kstevens Date 2005-07-07 Time 13:02 Sent To  
Notes
2005-07-07 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
  
 1. SHT 1 ACCESSIBLE FIXTURE DETAILS.
 SHOW THE FOLLOWING:
 FOR WATER CLOSETS
 A. FLUSH CONTROLS 11-4.16.5
 FOR LAVS
 A. FAUCETS 11-4.19.5
 FOR BREAK ROOM SINK
 A. SINK DEPTH 11-4.24.4
 B. CLEAR FLOOR SPACE 11-4.24.5 SHALL
 HAVE FORWARD APPROACH, AND EXTEND A
 MAXIMUM OF 19" UNDERNEATH THE SINK.
 C. EXPOSED PIPES & SURFACES 11-4.24.6
 D. FAUCETS 11-4.24.7
 2. SHTS 1 & 2, SHOW THE TURNING AREA IN
 EACH TOILET ROOM PER SECTION 11-4.22.3.
 THE TURNING AREA SHALL BE UNOBSTRUCTED,
 AND THE WATER CLOSET SHALL NOT BE INSIDE
 THE AREA.
 3. SHT 7 SANT. RISER DIAGRAM FOR TENANT
 #2, FITTINGS SHALL BE INSTALLED TO GUIDE
 THE WASTE & SEWAGE IN THE DIRECTION OF
 FLOW. SECTION 706.3. FITTINGS FOR THE
 W/C'S ARE GUIDING AGAINST THE FLOW.
 4. SHT 7 WATER RISER DIAGRAM, WATER
 HEATERS SHALL INDICATE REQUIRED THERMAL
 EXPANSION CONTROL PER SECTION 607.3.2.
 5. AN RPZ BACKFLOW IS REQUIRED ON THE
 WATER SERVICE OF THE BUILDING. 608.13.2.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2006-03-03 Cont ID  
Sent By mmclean Date 2006-03-03 Time 16:27 Rev Time 0.00
Received By mmclean Date 2006-03-03 Time 16:27 Sent To  
Notes
2006-03-03 00:00:00REVISION - ADDING OF A HC PARKING

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By gjoyce Date 2005-08-15 Time   Rev Time 0.00
Received By mmclean Date 2005-08-15 Time 14:46 Sent To B
Notes
2005-08-15 00:00:00APPROVED BY GRACE JOYCE, PLANNER
 822-1435 MM

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-22 Cont ID  
Sent By mmclean Date 2005-07-22 Time 14:09 Rev Time 0.00
Received By mmclean Date 2005-08-15 Time 14:45 Sent To  
Notes
2005-07-22 00:00:00DENIED,
 1. MUST PROVIDE A FULL SITEPLAN OF THE
 STRUCTURE WITH SETBACK.
 2. MUST SHOW THE ADDITION (COLUMNS) ON
 SITEPLAN WITH SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved