| Plan Review Stops For Permit 05060733 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-03 |
Time |
17:32 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-03 |
Time |
17:32 |
Sent To |
PC |
|
| Notes |
| 2005-08-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05060733 | | | ADD: 240 SUNSET RD | | | CONT:ATLAS SWIMMING POOLS | | | TEL: (561)585-0005 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | | | | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE | | | PROVIDED WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH | | | 424.2.17.1.14. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-07-07 |
Time |
17:07 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-07-07 |
Time |
17:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-15 |
Time |
06:53 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-07-15 |
Time |
06:43 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-22 |
Time |
07:55 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-06-22 |
Time |
07:48 |
Sent To |
P |
|
| Notes |
| 2005-06-22 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT DETAILS FOR THE PANEL | | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDU | | | IT SIZE AND TYPE, PANEL RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | IF AN ELECTRIC HEATER IS TO BE INSTALLED | | | PLEASE SUBMIT CALCULATIONS FOR THE MAIN | | | SERVICE. | | | | | | 2} THERE IS A HEATER SHOWN ON THE PLAN, | | | BUT NOT INCLUDED IN POOL DATA & | | | EQUIPMENT CRITERIA. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-14 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-14 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
| 2005-07-14 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
11:07 |
Sent To |
E |
|
| Notes |
| 2005-06-20 00:00:00 | TO ELEC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
18:08 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-30 |
Time |
14:02 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-07-30 |
Time |
14:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-24 |
Time |
15:41 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2005-06-24 |
Time |
15:41 |
Sent To |
B |
|
| Notes |
| 2005-06-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. APPLICATION DESCRIPTION INDICATES A | | | POOL & SPA, BUT SWIMMING POOL PLAN DOES | | | NOT SHOW A SPA. PLEASE CLARIFY. SECTION | | | 104.2.1. - APPLICATION STATES "DESCRIBE | | | PROJECT IN DETAIL". | | | 2. PIPING SCHEMATIC DOES NOT REFLECT THE | | | POOL DATA & EQUIPMENT & CRITERIA. PIPING | | | SCHEMATIC SHOWS A CLEANER LINE, SPA MAIN | | | DRAINS, SPA INLETS, ROSETTES (2 LINES), | | | POOL HEATER NOT SHOWN ON DATA & | | | EQUIPMENT & CRITERIA. PLEASE CORRELATE | | | SCHEMATIC WITH CRITERIAL. SECTION | | | 104.2.1. | | | 3. ENGINEERS SHALL LEGIBLY INDICATE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER OF | | | THE ENGINEERING BUSINESS ON EACH SHEET. | | | FAC 61G15-23.002(2) & FS 471.025. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-17 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-17 |
Time |
17:34 |
Sent To |
I |
|
| Notes |
|
|