| Plan Review Stops For Permit 05060730 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-09-01 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-09-01 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2006-09-01 00:00:00 | REVISION, CIVILS 1 THROUGH 3 | | | | | | ROUTED TO INCOMING, NEEDS ZONING AND | | | ENGINEERING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-07-06 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-07-06 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2006-07-06 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)RAMPS THAT ARE A PART OF A REQUIRED | | | MEANS OF EGRESS SHALL NOT BE LESS THAN | | | 44", FBC 11-4.8.3, EXCEPTION. | | | | | | 2.)PARKING IS TO COMPLY WITH CITY OF | | | WEST PALM BEACH STANDARD, SEE ATTACHED. | | | PLEASE INCORPORATE INTO THE PLAN DETAIL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-09-23 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-09-12 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2005-09-23 00:00:00 | APPROVED BY SAMANTHA ON 9/12/05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-09 |
Time |
09:30 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-08-09 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2005-08-09 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PLEASE SEE PREVIOUS REQUEST (ITEM | | | #3) FOR STATE OR LOCAL PRODUCT APPROVALS | | | FAC9B72.THIS IS REQUIRED IN ADDITION | | | TO THE NOAS.STATE APPROVALS ARE | | | AVAILABLE AT WWW.FLORIDABUILDING.ORG; | | | THE APPLICATION FOR LOCAL PRODUCT | | | APPROVAL IS ON THE SAME SITE. | | | | | | 2.)ON THE GLASS APPROVALS, PLEASE | | | CIRCLE METHOD OF ATTACHMENT AND GLASS | | | TYPES/SIZES TO BE INSTALLED.NOT ALL | | | ARE CODE COMPLIANT. | | | | | | 3.)SEE PREVIOUS LIST, ITEM #4.THE | | | PARAPET WALL 1-A8.1 WAS REVISED TO AN | | | EIFS SYSTEM, NOA01-0614.17.THIS IS | | | SMALL MISSILE IMPACT ONLY, SHUTTERS | | | REQUIRED.REMOVABLE SHUTTERS ON LARGE | | | COMMERCIAL BUILDINGS REQUIRES APPROVAL | | | BY THE BUILDING OFFICIAL, SEE ATTACHED | | | POLICY ITEM #13. | | | | | | 3.)THE CIVIL SHEET PREPARED BY SIMMONS | | | & WHITE (SHEET 2 OF 2) SHOWS THE | | | EXISTING BUILDING AS 53,368 SF.PLEASE | | | CLARIFY WHY THIS NUMBER IS DIFFERENT | | | FROM ID.00, EXISTING BUILDING 41,218 SF. | | | | | | 4.)SOME SHEETS HAD CHANGES WITHOUT | | | CLOUDS.TO EXPEDITE PLAN REVIEW, PLEASE | | | CLEARLY INDICATE ALL CHANGES TO THE | | | PLAN AND SUBMIT OLD SHEETS. | | | | | | 5.)(NEW COMMENT) THE DIMENSIONS ON LS1 | | | (A NEW SHEET, DATED 7/20/05) ARE NOT | | | CLEAR AS TO WHAT THEY CORRELATE WITH. | | | FOR INSTANCE, THE FARTHEST DISTANCE | | | (EXISTING SERVICE MANAGER) TO THE EXIT | | | HAS TWO DIMENSIONS, 175' AND 198'. | | | NEITHER APPEARS TO BE THE CORRECT | | | DISTANCE. THE COMMON PATH OF TRAVEL | | | APPEARS TO BE 160' WHEN SCALED; CANNOT | | | EXCEED 100' FBC1020.6.PLEASE REVISE | | | THE LS TO CLEARLY SHOW CODE COMPLIANCE. | | | | | | 6.)WHEN RESUBMITTING, CHANGE ONLY | | | SHEETS WHICH HAVE BEEN REVISED.OLD | | | SHEETS SUBMITTED SEPARATELY.ALL | | | CHANGES SHOULD BE CLOUDED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-11 |
Time |
17:53 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-07-11 |
Time |
17:53 |
Sent To |
Z |
|
| Notes |
| 2005-07-11 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)IMPACT FEES ARE DUE TO PALM BEACH | | | COUNTY.THE PLANS MUST BE STAMPED AND | | | THE RECEIPT ATTACHED TO THE APPLICATION. | | | 561-233-5025 FOR MORE INFORMATION. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED FOR: | | | | | | IMPACT STOREFRONT SYSTEM | | | ROOF | | | | | | ANY PRODUCT APPROVALS NOT SUBMITTED AND | | | REVIEWED FOR CODE COMPLIANCE PRIOR TO | | | ISSUANCE OF THE PERMIT WILL REQUIRE | | | SEPARATE PERMITS FOR THOSE ITEMS. | | | | | | 4.)FBC606, TYPE IV TO BE NON | | | COMBUSTIBLE WALLS.FBC TABLE 600, | | | FOOTNOTE (E) ALLOWS FIRE TREATED PLYWOOD | | | FOR THE ROOF BUT DOES NOT HAVE THE SAME | | | EXCEPTION FOR WALLS.THE PARAPET WALL | | | 1-A8.1 SHOWS FIRE TREATED PLYWOOD (OTHER | | | DETAILS MAY ALSO BE AFFECTED). | | | | | | 5.)1-A8.1, STUCCO OVER WIRE LATH IN A | | | VERTICAL APPLICATION TO BE 7/8", | | | FBC2504.2.2, ASTM C926. | | | | | | 6.)ID.00 SHOWS THE ADDITION AS 1905 | | | SQUARE FEEET; 1885 IS ON THE ENERGY | | | CALC. | | | | | | 7.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-30 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-30 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2006-06-30 00:00:00 | SHEETS A 4.1 WHICH SHOWS POWER/DATE IS | | | NOT AN ELECTRICAL SHEET AND IS FOR | | | REFERENCE ONLY. | | | NO ELECTRICAL REVIEW DONE, AS E-SHEETS | | | WERE NOT SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-09-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-03 |
Time |
19:07 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-09-03 |
Time |
19:02 |
Sent To |
|
|
| Notes |
| 2005-09-03 00:00:00 | ELECTRICAL SHEETS STAMPED. OK |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-04 |
Time |
09:10 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-08-04 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2005-08-04 00:00:00 | ******** UNSAT ****** | | | | | | 1)NOTE: PLEASE SEE BOTH SETS ARE TO BE | | | SIGNED DATED AND SEALED BY ENGINEER OF | | | RECORD. FS 471.025,FAC 61G15-23.002 | | | PLEASE SEE ONE SET, NEW REVISED SHEETS. | | | PLEASE SEE ELECTRICAL COMMENTS WERE | | | ADDRESSED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-01 |
Time |
07:04 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-30 |
Time |
21:05 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | ************ UNSAT ********** | | | | | | 1)NOTE: PLEASE CLARIFY/SHOW NEW OR | | | EXISTING ROOFTOP GFI RECEPT FOR A/C | | | RTU'S. 210.63,210.8 | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT FOR | | | SHOW WINDOW ON WEST AND NORTH OF SHOW | | | RM. | | | 210.62 | | | | | | 3)NOTE: PLEASE SEE MDP IS SHOWN BLANK | | | AND NO NEW LOADS AND/OR EXISTING LOADS | | | ARE SHOWN? | | | PLEASE ALSO SEE ALL CONTINUOUS LOADS AND | | | LARGEST MOTOR LOADS TO BE SHOWN @125%. | | | 215.3,230.42,220 ETC. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS. | | | | | | PLEASE BE SURE ALL OLD/VOIDED SHEETS ARE | | | REMOVED FROM SETS AND ONLY NEW REVISED | | | SHEETS ARE INSERTED INTO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | PLEASE SEE ONE SET OF OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | 2005-06-30 00:00:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2006-10-20 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-20 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-20 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-09-08 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-09-08 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2006-09-08 00:00:00 | NEED THE FOLLOWING INFO: | | | | | | 1. POLLUTION PREVENTION PLANS & DETAILS | | | 2. STORM WATER CALCULATIONS,RUNOFF CAL., | | | PRE & POST CALS., PERVIOUS,IMPERVIOUS | | | AREA CHANGES, | | | 3. NOTES ON DRAWINGS FOR PARKINGS, | | | HANDICAP PARKINGS, ADA STANDARDS, CITY | | | OF WPB STANDARDS ETC., SHOULD BE | | | INCLUDED IN THE DRAWINGS & DRAWN PER | | | NOTES. | | | 4. DUMPSTER ENCLOSURE MUST MEET CITY OF | | | WPB STANDARDS. | | | 5. DRIVEWAY, APPROACH, SIDEWALK,CURBS, | | | ETC. MUST MEET CITY OF WPB STANDARDS. | | | 6. PLEASE MAKE SURE PARKING LOT | | | ELEVATIONS ARE THAN ROAD ELEVATION AND | | | MUST MEET FLORIDA BLDG CODES. | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-09-13 |
Time |
14:21 |
Rev Time |
0.50 |
| Received By |
rchokshi |
Date |
2005-09-13 |
Time |
14:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-07-05 |
Time |
16:23 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2005-07-05 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-07-03 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-03 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-14 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-14 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-10 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-10 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2005-08-10 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE NOTE THAT YOUR RESPONSE TO | | | COMMENT #4 INDICATES WHEN VEHICLES WILL | | | BE RUNNING OR OFF. AS PER THE FIRST | | | REVIEW, VEHICLES WHEN STORED INSIDE MUST | | | HAVE ONE BATTERY CABLE DISCONNECTED AND | | | LOW FUEL. | | | | | | 2) ALTHOUGH THE BUILDING ADDRESS IS | | | EXISTING, PLEASE ILLUSTRATE ON PLANS AND | | | ADDRESS MUST BE AT LEAST 6" IN HEIGHT | | | AND CONTRASTING TO BACKGROUND. | | | | | | 3) PLEASE SEE OTHER REVIEW COMMENTS IN | | | REGARDS TO FS AND FAC REQUIREMENTS FOR | | | PLANS. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. | | | | | | 5) PLEASE DIRECT YOUR RESPONSE TO THE | | | PLANS REGARDING EMERGENCY LIGHTING | | | FACILITIES WITH THE CORRELATING SHEET | | | NUMBER. | | | | | | | | | MIKE WENNERGREN, CAPTAIN | | | WPBFR(561) 804-4756 | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-07-11 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-07-11 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2005-07-11 00:00:00 | 1. KNOX-BOX WILL BE REQUIRED. | | | | | | 2. PLEASE DISPLAY EMERGENCY LIGHTING. | | | | | | 3. SITE PLAN DOES NOT DIPLAY FIRE | | | HYDRANTS INSIDE OR OUTSIDE THE CAMPUS. | | | | | | 4. PLEASE INDICATE ON THE PLANS HOW | | | THE VEHICLES WILL BE DISPLAYED. | | | BATTERIES ARE TO BE DISCONNECTED AND | | | THEY SHALL CONTAIN VERY LITTLE FUEL. | | | | | | 5. PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | | | 6. NEW SOFFIT SHALL NOT OBSCURE FIRE | | | SPRINKLER HEADS. | | | | | | 7. BUILDING ADDRESS WILL BE REQUIRED. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 835-2910 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-16 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-16 |
Time |
11:25 |
Sent To |
ENG |
|
| Notes |
| 2006-10-16 11:26:04 | TO "ENG" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2006-10-12 13:47:09 | TO "COMM" BD#27 | | 2006-09-23 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-01 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-01 |
Time |
08:38 |
Sent To |
Z |
|
| Notes |
| 2006-09-05 00:00:00 | DENIED BY ZONING.SENT TO ENGINNERING | | | IN-BOX. | | | | | | | | 2006-09-01 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
12:59 |
Sent To |
ENG |
|
| Notes |
| 2006-08-14 00:00:00 | TO "ENG' BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-19 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | TO "COMM" BD#3 | | 2006-06-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-31 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-31 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2005-08-31 00:00:00 | TO "COMM" BD#48 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-28 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-28 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2005-07-29 00:00:00 | TO "COMM" BD#43 | | 2005-07-28 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-07 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-07 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2005-07-07 00:00:00 | TO "COMM" BD#40/W ORIGINAL APPL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-11 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-09 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2005-06-10 00:00:00 | COMM BOARD #40 | | 2005-06-09 00:00:00 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-11 |
Time |
13:32 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-07-11 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2005-07-11 00:00:00 | PROVISO: | | | 2001 FBC(M)502.11 EXCEPTION #3: | | | MECHANICAL EXHAUST WILL NOT BE REQUIRED | | | SO LONG AS MOTOR VECHICLES WILL ONLY RUN | | | WHILE MOVING TO MOVE VECHICLES IN AND | | | OUT OF THE BUILDING (NO IDLING). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-24 |
Time |
16:38 |
Rev Time |
1.33 |
| Received By |
kstevens |
Date |
2005-08-24 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-08-24 00:00:00 | PASSED/PROVISO | | | | | | ARCHITECT INDICATED THAT AN EXISTING | | | SERVICE SINK WAS IN THE BUILDING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-09 |
Time |
08:38 |
Rev Time |
1.33 |
| Received By |
kstevens |
Date |
2005-07-09 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2005-07-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | | | | 1. SUBMIT CALCULATIONS FOR MINIMUM | | | FACILITIES. INDICATE THE SQUARE FOOTAGE | | | OF THE EXISTING BUILDING, THE SQUARE | | | FOOTAGE OF EACH OCCUPANCY, AND THE | | | SQUARE FOOTAGE OF THE ADDITION. INDICATE | | | THE NUMBER OF FIXTURES REQUIRED PER | | | TABLES 1003.1 (BLDG) AND 403.1 (PLMG). | | | 2. SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS. SHOW SF OF NEW | | | ROOF AND SHOW 1/2 AREA OF ALL VERTICAL | | | WALLS INCLUDING PARAPETS ADDED TO THE | | | AREA OF THE ROOF IN THE CALCULATIONS. | | | 3. MORE INFORMATION REQUIRED FOR ROOF. | | | APPLICATION INDICATES 6,263SF ADDITION, | | | BUT ROOF DRAIN AREAS ONLY ADD UP TO | | | 2,500SF. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-10-16 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-10-16 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2006-10-16 10:05:50 | FAILED | | | | | | THE PLAN SUBMITTED WITH THE PERMIT DOES NOT MATCH THE | | | CURRENTLY APPROVED PARKING LAYOUT.THE PLAN SUBMITTED | | | MATCHES THE PLANS THAT HAVE NOT PROCEEDED TO THE CITY | | | COMMISSION FOR APPROVAL. | | | | | | ERIC SCHNEIDER (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-09-05 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-09-05 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | THE REVISION TO THE PARKING AREA HAS NOT | | | BEEN APPROVED BY THE CITY COMMISSION | | | THROUGH THE MAJOR DSI AMENDMENT PROCESS. | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-07-19 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-07-19 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2006-07-19 00:00:00 | 1) THE ADDITION OF THE RAMPS DOES NOT | | | MATCH THE APPROVED LANDSCAPE PLAN. | | | | | | 2) NO LANDSCAPE PLAN SUBMITTED. | | | | | | 3) DSI AMENDMENT REQUIRE TO MODIFY THE | | | SITE PLAN. | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
jlong |
Date |
2005-07-13 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
jlong |
Date |
2005-07-13 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | RESOLUTION NO. 256-05 PASSED CITY | | | COMMISSION ON JUNE 6, 2005 WHICH | | | APPROVED THIS RENOVATION PROJECT. |
|
|