Plan Review Details - Permit 05060615
Plan Review Stops For Permit 05060615
Review Stop E ELECTRICAL
Rev No 3 Status N Date 2005-08-02 Cont ID  
Sent By btrobaug Date 2005-08-02 Time 07:29 Rev Time 0.50
Received By btrobaug Date 2005-08-02 Time 07:26 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-26 Cont ID  
Sent By btrobaug Date 2005-07-26 Time 12:26 Rev Time 1.00
Received By btrobaug Date 2005-07-19 Time 09:11 Sent To PC
Notes
2005-07-26 00:00:00HOLDING AT MY DESK WAITING FOR GAS
 APPLICATION. 7/26/05

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-06-27 Cont ID  
Sent By btrobaug Date 2005-06-27 Time 09:00 Rev Time 0.50
Received By btrobaug Date 2005-06-27 Time 08:23 Sent To M
Notes
2005-06-27 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} INDICATE THE PRIME MOVER FO RTHE
 GENERATOR.
  
 2} PLEASE PROVIDE A SITE PLAN INDICATING
 THE PHYSICAL LOCATION OF ALL SERVICE AND
 EMERGENCY EQUIPMENT.
  
 3} SUBMIT SPECIFICATIONS FOR THE
 TRANSFER SWITCH. INDICATE COMPLIANCE
 WITH 702.8
  
 4} SUBMIT LOAD CALCULATIONS FOR THE
 INTENDED CONNECTED EMERGENCY LOAD.
  
 5} THE PLAN SUBMITTED MUST BE SEALED BY
 THE ARCHITECT OF RECORD PER 481 FS.
 NOTE: THE CONTRACTOR MAY USE HIS OWN
 PLANS UNDER 481.229 FS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-20 Cont ID  
Sent By shill Date 2005-06-20 Time 11:03 Rev Time 0.00
Received By shill Date 2005-06-20 Time 11:03 Sent To E
Notes
2005-06-20 00:00:00TO ELEC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-08 Cont ID  
Sent By shill Date 2005-06-08 Time 15:01 Rev Time 0.00
Received By shill Date 2005-06-08 Time 15:01 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-06 Cont ID  
Sent By hmoser Date 2005-07-06 Time 10:35 Rev Time 0.00
Received By hmoser Date 2005-07-06 Time 10:47 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-02 Cont ID  
Sent By jleech Date 2005-08-02 Time 07:07 Rev Time 0.25
Received By jleech Date 2005-08-02 Time 07:07 Sent To E
Notes
2005-08-02 00:00:00GAS APP. RECIEVED #05060615

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-07-09 Cont ID  
Sent By hmoser Date 2005-07-06 Time 10:47 Rev Time 0.33
Received By jleech Date 2005-07-09 Time 07:23 Sent To B
Notes
2005-07-09 00:00:00NO GAS PLAN OR PERMIT APPLICATION WITH
 GEN AIR PERMIT APPLICATION. HAVE
 PLUMBING CONTRACTOR SUBMIT PLANS WITH
 APPLICATION.
 GAS REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2005-07-26 Cont ID  
Sent By mmclean Date 2005-07-26 Time 12:18 Rev Time 0.00
Received By mmclean Date 2005-07-26 Time 12:18 Sent To E
Notes
2005-07-26 00:00:00GENERATOR CAN ONLY ENROACH 4FT INTO
 SETBACK.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-06-17 Cont ID  
Sent By mmclean Date 2005-06-17 Time 17:52 Rev Time 0.00
Received By mmclean Date 2005-06-17 Time 17:52 Sent To B
Notes
2005-06-17 00:00:00DENIED,
 1. NEED TO PROVIDE THE DISTANCE THE
 GENERATOR WILL FROM PROPERTY LINE IN THE
 REAR
 2. NEED TO PROVIDE THE DIMENSION OF THE
 GENERATOR
  
 **GENERATOR CAN ONLY ENCROACH 4FT INTO
 SETBACK**
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720