| Plan Review Stops For Permit 05060589 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-14 |
Time |
10:21 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-10-14 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2005-10-14 00:00:00 | ***PROVISO***ELEVATION CERT REQUIRED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-02 |
Time |
07:34 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-09-02 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2005-09-02 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)SEE PREVIOUS LIST, ITEM #1, PROVIDE | | | ANCHORING INFORMATION TO COMPLY WITH | | | FBC1606.1.3; STRUCTURAL MEMBERS AND | | | SYSTEMS, AND COMPONENTS AND CLADDING IN | | | A BUILDING OR STRUCTURE SHALL BE | | | ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED. | | | | | | 2.)PROVIDE THE ORIGINAL PERMIT | | | APPLICATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-01 |
Time |
11:50 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-01 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2005-07-01 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED. | | | | | | 2.)THE VALUE IS TOO LOW.PROVIDE A | | | REASONABLE VALUE OR AN ESTIMATED VALUE | | | WILL BE DONE FOR YOU USING MARSHALL & | | | SWIFT. | | | | | | 3.)PROVIDE A SURVEY AND SITE PLAN | | | SHOWING THE LOCATION OF THE GENERATOR | | | AND SLAB. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-16 |
Time |
18:58 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-16 |
Time |
18:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-16 |
Time |
12:59 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-16 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE INDICATE WHICH FLOOD ZONE THIS | | | PROJECT IS IN. PROVIDE A FLOOD ELEVATION | | | CERTIFICATE. | | | | | | 2} THE INFORMATION SUBMITTED FOR THE | | | TRANSFER SWITCH DOES NOT INDICATE IT IS | | | SERVICE RATED PER 225.36, . PLEASE | | | INDICATE THAT IT IS PER SPEC'S OR | | | INDICATE COMPLIANCE WITH THAT ARTICLE. | | | | | | 3} THE PLANS MUST BEAR THE SIGNATURE AND | | | PRINTED NAME OF THE PERSON RESPONSIBLE. | | | | | | 4} PLEASE ATTACH THE ORIGINAL PERMIT | | | APPLICATION WHEN RESUBMITTING. CURRENTLY | | | ONLY TWO HALF COPIES ARE IN THE PACKAGE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-22 |
Time |
14:17 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-06-16 |
Time |
12:17 |
Sent To |
I |
|
| Notes |
| 2005-06-16 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} IT APPEARS THAT LINE AND LOAD FOR THE | | | DISCONNECTS ARE IN THE SAME GUTTER. SHOW | | | SEPARATION PER 230.7. | | | | | | 2} SHOW LOCATION OF DISCONNECTING MEANS | | | FOR GENERATOR FEEDERS PER 225.31, 32, | | | 36. | | | | | | 3} SUBMIT MANUFACTURERS SPECS FOR THE | | | GENERATOR AND TRANSFER SWITCH. | | | | | | 4} THE PLANS INDICATE THE FEEDERS FROM | | | THE GENERATOR ARE #4/0(CU?) AND THE | | | GENERATOR APPEARS TO HAVE A 250 AMP OCP. | | | SEE 445.13 FOR 115% AND 310.16 FOR | | | ALLOWABLE AMPACITIES. | | | | | | 5} PLEASE FURNISH CALCULATIONS FOR THE | | | LOADS SELECTED TO BE SUPPLIED ON | | | EMERGENCY POWER. | | | | | | 6} THE COST OF ALL EQUIPMENT BEING | | | INSTALLED MUST BE INCLUDED ON THE | | | APPLICATIION, EVEN THOUGH OWNER | | | SUPPLIED. 104.2.1 CWPB AMMENDMENTS. | | | | | | 7} PLEASE INDICATE WHICH FLOOD ZONE THIS | | | PROJECT IS IN. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-09 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-09 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-06 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-06 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2005-09-06 00:00:00 | ******PROVISO****** | | | | | | PLEASE PROVIDE FURTHER INFORMATION | | | REGARDING FUEL AMOUNT AND STORAGE. PLANS | | | WILL BE RESUBMITTED FOR OTHER REVIEW | | | COMMENTS, AND WILL BE STAMPED BY FIRE AT | | | THAT TIME. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-12 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-12 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | ******DENIED****** | | | | | | 1) WORK TO COMPLY WITH NFPA 110 AND | | | OTHER APPLICABLE CODES. | | | | | | 2) PLEASE ILLUSTRATE THE ON SITE | | | LOCATION OF THE GENERATOR AND FUEL | | | SUPPLY. | | | | | | 3) PLEASE PROVIDE MANUFACTURER CUT | | | SHEETS FOR THE PROPOSED GENERATOR. | | | | | | 4) PLEASE SHOW WHERE EXHAUSTING WILL | | | OCCUR IN REGARDS TO SURROUNDING | | | STRUCTURES AND OR OPENINGS. | | | | | | 5) PLEASE PROVIDE ADDITIONAL INFORMATION | | | IN REGARDS TO THE FUEL SUPPLY AND SIZE | | | OF STORAGE. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 805-6722 OR 835-2951 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-03 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-03 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2005-10-12 00:00:00 | TO "COMM" BD#33 | | 2005-10-03 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | TO "COMM" BD#50 | | 2005-08-10 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-22 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-22 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | TO "COMM" BD#7 | | 2005-06-22 00:00:00 | WAITING FOR SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-10 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-10 |
Time |
17:20 |
Sent To |
E |
|
| Notes |
| 2005-06-10 00:00:00 | TO ELEC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
11:26 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-09 |
Time |
07:43 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-09-09 |
Time |
07:07 |
Sent To |
|
|
| Notes |
| 2005-09-09 00:00:00 | PROVISO: | | | PLEASE PROVIDE ANCHORING DETAIL FOR THE | | | GENERATOR TO THE SLAB PER 2001 FBC | | | 1606.1.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-20 |
Time |
07:02 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-07-20 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2005-07-20 00:00:00 | DENIED: | | | 1.PROVIDE MANUFACTURER SUBMITTAL DATA | | | FOR THE DIESEL GENERATOR. | | | | | | 2.PROVIDE SITE PLAN OR SURVEY, | | | INDICATE DISTANCES FROM THE PROPERTY | | | LINES, AND ADJACENT BUILDINGS. | | | | | | 3.INDICATE DISTANCES FROM DOORS, | | | WINDOWS AND FRESH AIR INTAKES.SHOW | | | COMPLIANCE WITH 2001 FBC(M)401.5 & | | | 501.3. | | | | | | 4.PROVIDE DETAIL FOR ANCHORING OF THE | | | GENERATOR IN ACCORDANCE WITH 2001 FBC | | | 1606.1.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-29 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-29 |
Time |
15:45 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-10 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-10 |
Time |
08:46 |
Sent To |
I |
|
| Notes |
| 2005-06-10 00:00:00 | | | | THE FOLLOWING IS NOT A ZONING PLAN | | | REVIEW, IT IS A RECORD OF TELEPHONE | | | CONVERSATION ONLY: | | | | | | TELEPHONE CONVERSATION WITH JOHN BELL | | | (TEL: 561-688 2299 AND 561-262 6566) ON | | | 6/10/05 AT 9:30AM: | | | | | | MR BELL CONFIRMED THAT THE NEW GENERATOR | | | WILL BE EXTERIOR EQUIPMENT.HE WAS THEN | | | ADVISED THAT THE SUBMITTED PLANS DO NOT | | | MAKE THAT CLEAR AND HE WILL BE REQUIRED | | | TO SUBMIT A SURVEY DRAWING WITH | | | DIMENSIONS TO SHOW THE EQUIPMENT | | | LOCATION IN RELATION TO PROPERTY LINES. | | | DENIED, | | | 1. MUST PROVIDE TWO COPY OF SURVEY | | | SHOWING THE LOCATION OF THE GENERATOR | | | AND THE SETBACKS FROM THE PROPERTY LINE | | | AND IF ANY STRUCTURE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|