Plan Review Details - Permit 05060582
Plan Review Stops For Permit 05060582
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-08-27 Cont ID  
Sent By shill Date 2005-08-27 Time 14:36 Rev Time 0.50
Received By shill Date 2005-08-27 Time 14:36 Sent To  
Notes
2005-08-27 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)THE ARCHITECT'S SEAL IS TO BE DATED
 (D1 AND D2), FAC61G1-16.003, 004.PLANS
 ARE OTHERWISE CODE COMPLIANT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-08-18 Cont ID  
Sent By shill Date 2005-08-18 Time 08:29 Rev Time 1.00
Received By shill Date 2005-08-18 Time 08:29 Sent To  
Notes
2005-08-18 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE TOTAL RISE SHOWN ON BSP1 IS 36"
 WITH FIVE RISERS, EACH INDIVIDUAL RISER
 WOULD BE 7.2" WHICH EXCEEDS THE 7"
 MAXIMUM FBC1007.3.1. THIS IS IN CONFLICT
 WITH D-SP1 WHICH SHOWS 7" RISERS.
  
 2.)THE HANDRAIL FOR THE STAIRS IS TO
 BE ROUNDED OR RETURNED SMOOTHLY TO THE
 FLOOR, FBC11-4.9.4(6).SEE FIGURE 11-19
 FOR AN EXAMPLE.
  
 3.)FROM PREVIOUS LIST, SECTION B-SP1
 SHOWS ONE RAIL, D-SP1 (PLAN) APPEARS TO
 SHOW TWO (GUARDRAIL AND HANDRAIL).
 PLEASE CLARIFY WITH CODE COMPLIANT
 DETAILS. TO FURTHER CLARIFY THE PREVIOUS
 COMMENT, PLEASE PROVIDE A DETAIL FOR THE
 GUARDRAIL IN COMPLIANCE WITH FBC1015.
 THE PLAN APPEARS TO SHOW ONE BUT NO
 DETAIL IS PROVIDED.
  
 4.)A GUARDRAIL IS REQUIRED AT THE
 RAMP AND DECK FBC1015.PLEASE PROVIDE
 DETAILS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-30 Cont ID  
Sent By shill Date 2005-06-30 Time 15:48 Rev Time 2.50
Received By shill Date 2005-06-30 Time 12:12 Sent To  
Notes
2005-06-30 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)IT APPEARS THAT THE RISE OF THE
 STAIRS IS 7" (D-SP1); PLEASE PROVIDE THE
 RUN DIMENSION IN COMPLIANCE WITH
 FBC1007.3.1.
  
 2.)A-SP1, SPECIFY JOIST HANGER AND
 STRAP.
  
 3.)PLEASE PROVIDE A DETAIL FOR THE
 HANDRAILS IN COMPLIANCE WITH FBC11-4.26,
 FBC1007.5.
  
 4.)THE STAIR HANDRAILS ARE TO COMPLY
 WITH FBC
  
 4.)IF RAMPS CHANGE DIRECTIONS AT
 LANDINGS, THE MINIMUM LANDING SIZE SHALL
 BE 60 INCHES BY 60 INCHES FBC11-4.8.4.
  
 5.)SHOW THE 60" CLEAR AT THE TOP
 LANDING OF THE RAMP FBC11-4.8.4(2).
  
 6.)THE RAMP HANDRAILS ARE TO COMPLY
 WITH FBC11-4.8.5(2).
  
 7.)SECTION B-SP1 SHOWS ONE RAIL, D-SP1
 (PLAN) APPEARS TO SHOW TWO (GUARDRAIL
 AND HANDRAIL).PLEASE CLARIFY WITH CODE
 COMPLIANT DETAILS.SECTION B-SP1 DOES
 NOT SHOW A HANDRAIL AT THE REQUIRED
 HEIGHT FBC1007.5.
  
 8.)EXTENSIONS AT THE TOP AND BOTTOM OF
 THE STAIRS TO COMPLY WITH
 FBC11-4.9.4(2), FBC11 FIGURE 19.
  
 8.)SHOW THE ACCESSIBLE ROUTE TO THE
 RAMP AND ACCESSIBLE STAIR.A SIDEWALK
 IS SHOWN LEADING TO ONE STAIR BUT NOT
 SHOWN FOR THE RAMP/STAIR.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-08-19 Cont ID  
Sent By dpalmer Date 2005-08-19 Time 18:48 Rev Time 0.50
Received By dpalmer Date 2005-08-19 Time 18:48 Sent To  
Notes
2005-08-19 00:00:00NEW RISER DIAGRAM SUBMITTED.
  
 REDLINED TWO GRNDS RODS AT MAIN SERVICE
 LOCATION.
 250.50

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-08-09 Cont ID  
Sent By dpalmer Date 2005-08-09 Time 20:49 Rev Time 0.25
Received By dpalmer Date 2005-08-09 Time 20:49 Sent To  
Notes
2005-08-09 00:00:00** UNSAT **
  
 1)NOTE; PLEASE SEE MISSING FPL METERING
 DEVICE / METER CAN AT SERVICE LOCATION
 AT TRANSFORMER.
 PLEASE SEE SERVICE LOCATION AT
 TRANSFORMER WILL BE REQUIRED TO CONTAIN
 GROUDING ELECTRODE SYSTEM.
 250.50,250.24, 250.66.
 PLEASE SEE SECONDARY LOCATION AT
 TRAILERS WILL BE THE "DETACHED"
 STRUCTURE. PLEASE VERIFY IF CWP PIPING
 FOR TAILERS IS METAL? IF SO, CWP SHALL
 BE A PART OF THE GROUNDING ELECTRODE
 SYSTEM. 250.50
  
 2)NOTE: PLEASE VERIFY CONDUCTORS IN
 RISER AND GUTTER. SHOW CONDUCTORS TO
 SECONDARY MAINS AT GUTTER/ SERVICE RACK
 LOCATION. CONDUCTORS IN RISER AT
 TRANSFORMER LOCATION.
  
 PLEASE CALL, IF THERE ARE ANY QUESTIONS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-06-14 Cont ID  
Sent By dpalmer Date 2005-06-14 Time 11:20 Rev Time 0.25
Received By dpalmer Date 2005-06-14 Time 11:20 Sent To  
Notes
2005-06-14 00:00:00*********** UNSAT ***********
  
 1)NOTE: PLEASE SUBMIT A COMPLETE
 ELECTRICAL RISER DIAGRAM SHOWING ALL
 DISCONNECTS, SEC'S, FEEDERS, CONDUIT(S),
 GROUNDING ELECTRODE SYSTEM, GROUNDING AT
 TRIALERS ETC.
 215.5,310.16,240.4,250,,,
  
 2)NOTE:PLEASE SUBMIT LOAD CALCULATIONS
 FOR TEMP SERVICE SERVING NEW TRAILERS.
 220/215.5
  
 PLEASE SEE ANY REVIEW COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-08-24 Cont ID  
Sent By mwennerg Date 2005-08-24 Time 11:36 Rev Time 0.00
Received By mwennerg Date 2005-08-24 Time 11:36 Sent To  
Notes
2005-08-24 00:00:00******PROVISO******
  
 PLEASE SEE BUILDING REVIEW COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-07-01 Cont ID  
Sent By mwennerg Date 2005-07-01 Time 13:06 Rev Time 0.00
Received By mwennerg Date 2005-07-01 Time 13:06 Sent To  
Notes
2005-07-01 00:00:00******DENIED******
  
 1) PLEASE PROVIDE DETAILS AND
 PRESCRIPTIVE STRENGTH REQUIREMENT FOR
 HANDRAILS AND GUARDS.
  
 2) ILLUMINATED EXIT SIGNS ARE REQUIRED.
  
 3) LIFE SAFETY TO COMPLY WITH NFPA 101,
 2003 EDITION.
  
  
 MIKE WENNERGREN, A/CAPTAIN
 WPBFR(561) 805-6722 OR 835-2951

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-09 Cont ID  
Sent By adarroug Date 2005-08-09 Time 08:23 Rev Time 0.00
Received By adarroug Date 2005-08-09 Time 08:23 Sent To  
Notes
2005-08-09 00:00:00TO "COMM" BD#55

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-28 Cont ID  
Sent By adarroug Date 2005-06-28 Time 09:05 Rev Time 0.00
Received By adarroug Date 2005-06-28 Time 09:06 Sent To  
Notes
2005-06-28 00:00:00SUBMITTAL PUT IN "COMM" BD#26 WITH
 ORIGINAL APPLICATION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date 2005-06-10 Cont ID  
Sent By shill Date   Time 15:29 Rev Time 0.00
Received By shill Date 2005-06-08 Time 11:43 Sent To  
Notes
2005-06-10 00:00:00COMM BOARD #26
  
2005-06-08 00:00:00TO THE TABLE WAITING TO GO ON COMM BD.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-18 Cont ID  
Sent By pkrauss Date 2005-07-15 Time 16:50 Rev Time 0.55
Received By pkrauss Date 2005-07-15 Time 15:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-08-25 Cont ID  
Sent By kstevens Date 2005-08-25 Time 08:38 Rev Time 0.45
Received By kstevens Date 2005-08-25 Time 08:38 Sent To  
Notes
2005-08-25 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A. FROM PREVIOUS REVIEW:
 1. SITE PLAN SHALL SHOW THE LOCATION OF
 THE SANITARY SEWER AND SHOW THE SEWER
 ROUTE FROM THE TRAILER. SECTION 104.2.1.
 - ALSO SHOW WHERE THE SEWER CONNECTS TO
 EXISTING SEWER LINE. SHOW CLEANOUTS.
 **************NEW COMMENT***************
 1B. ENGINEER SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER IN THE
 TITLE BLOCK. FAC 651GF154-23.002(2) AND
 FS 471.025.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-07-09 Cont ID  
Sent By kstevens Date 2005-07-09 Time 11:49 Rev Time 0.25
Received By kstevens Date 2005-07-09 Time 11:49 Sent To  
Notes
2005-07-09 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FBC-2001 PLUMBING.
  
 1. SITE PLAN SHALL SHOW THE LOCATION OF
 THE SANTIARY SEWER AND SHOW THE SEWER
 ROUTE FROM THE TRAILER. SECTION 104.2.1.
 2. SITE PLAN SHALL SHOW THE LOCATION OF
 THE WATER SERVICE. SHOW THE POINT OF
 CONNECTION AND AN RPZ BACKFLOW IS
 REQUIRED ON THE WATER SERVICE. SECTION
 608.13.2. SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2005-06-29 Cont ID  
Sent By sgraham Date 2005-06-29 Time 08:48 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-06-27 Cont ID  
Sent By adarroug Date 2005-06-27 Time 16:53 Rev Time 0.00
Received By adarroug Date 2005-06-27 Time 12:46 Sent To  
Notes
2005-06-27 00:00:00DENIED NEED A SITE PLAN OF THE PROPERTY
 SHOWING THE LOCATION OF THE TRAILERS,
 LANDSCAPING AND PARKING.