| Plan Review Stops For Permit 05060577 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-09-02 |
Time |
09:51 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-09-02 |
Time |
08:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-12 |
Time |
16:55 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-12 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED. | | | | | | 2.)PROVIDE A SITE PLAN SHOWING THE | | | LOCATION WHERE THE GENERATOR WILL BE | | | INSTALLED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-29 |
Time |
07:16 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-08-29 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | SHEET E-4 FOR REFERENCE OF LOCATION OF | | | GENERATOR. | | | SHEET E-11 FOR REFERENCE OF GENERATOR, | | | ATS AND FIREPUMP ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-29 |
Time |
17:06 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-29 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2005-06-29 00:00:00 | ********* UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE FIRE PUMP AND FIRE | | | PUMP CONTROLLER WAS SUBMITTED WITH | | | GENERATOR/ATS PERMIT. | | | PLEASE SEE FIRE PUMP IS TO BE SUBMITTED | | | UNDER SEPARATE PERMIT . | | | PLEASE INCLUDE EXISTING RISER DIAGRAM | | | WITH THE FIRE PUMP PERMIT APPLICATION | | | PACKAGE. NOTE: RISER FOR EXISTING BLDG | | | REQUIRES PLANS TO BE SIGNED, DATED AND | | | SEALED BY ENGINEER OF RECORD. | | | PLEASE ALSO SUBMIT THREE SETSOF PLANS | | | AND SPECS AS THIS IS A THRESHOLD BLDG. | | | PLEASE SEE MECH/ FIRE REVIEW NOTES, FUEL | | | IS ALSO UNDER A SEAPARATE PERMIT. | | | 215.5, FBC 104.2.1 | | | | | | 2)NOTE: PLEASE PROVIDE RISER DIAGRAM FOR | | | INSTALLATION OF GEN, ATS. THREE SETS OF | | | SIGNED, SEALED PLANS, SPECS ETC FOR GEN | | | PERMIT. PLEASE BE SURE KW RATING OF GEN | | | SPECS CORRELATE WITH PLANS/RISER. | | | | | | *************************************** | | | PLEASE SEE THE ABOVE IS REQUIRED DUE TO | | | THIS INFORMATION NOT BEING SUBMITTED ON | | | ORIGINAL BLDG PLANS. A "PROVISO" | | | CONDITION WAS GIVEN IN ORDER TO ISSUE | | | THE BASE BLDG PERMIT. THE CONDITION | | | AGREED AND SET-FORTH WAS ALL OF THE | | | ABOVE WAS TO BE SUBMITTED UNDER SEPARATE | | | PERMITS, SEPARATE FEES ETC. | | | PLEASE SEE THIS APPLICATION IS ONLY FOR | | | INSTALLATION OF GEN AND ATS. | | | | | | *************************************** | | | | | | PLEASE SEE ANY POSSIBEL COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-08 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-08 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-07-12 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-07-12 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE ILLUSTRATE THE ON SITE | | | LOCATION OF THE GENERATOR AND FUEL | | | SUPPLY. | | | | | | 2) PLEASE NOTE THAT SEPARATE SHOP | | | DRAWINGS AND PERMIT IS REQUIRED FOR FIRE | | | PUMP INSTALLATION. AT THAT TIME, PLEASE | | | PROVIDE CUT SHEETS AND FACTORY CURVE | | | INFORMATION. | | | | | | 3) IN ACCORDANCE WITH LOCAL REQIREMENTS, | | | A NEW FIRE PUMP SERVING A HIGHRISE | | | STRUCTURE SHALL BE A MINIMUM OF 1250 | | | GPM. | | | | | | 4) PLEASE SHOW THE LOCATION OFEXHAUST | | | IN REGARDS TO SURROUNDING AREA AND | | | OPENINGS. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 805-6722 OR 835-2951 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-15 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-15 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2005-08-17 00:00:00 | TO "COMM" BD#18 | | 2005-08-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-14 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-06-09 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2005-06-17 00:00:00 | COMM BOARD 21 | | | | | 2005-06-09 00:00:00 | ON TABLE WAITING TO GO ON COMM BD. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-09-08 |
Time |
08:11 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-09-08 |
Time |
07:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-14 |
Time |
07:07 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-07-14 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2005-07-14 00:00:00 | DENIED: | | | ADDITIONAL INFORMATION REQUIRED: | | | 1.PLEASE PROVIDE PLANS OR REFERENCE | | | EXISTING PLANS (PROVIDE PAGE/DRAWING #) | | | THAT SHOW LOCATION OF THE GENERATOR & | | | VENTILATION FOR THE ROOM. | | | | | | 2.PLEASE INDICATE DISTANCES FROM | | | PROPERTY LINES, ADJACENT BUILDINGS, AND | | | AIR INTAKES (I.E. WINDOWS, DOORS, | | | LOUVERS, ETC). | | | | | | 3.PLEASE CARIFY IF A REMOTE FILL OR | | | STORAGE WILL BE UTILIZED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-08-28 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-08-28 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-08-28 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2005-08-28 00:00:00 | DIESEL FUEL, PLUMBING NOT EQUIRED. |
|
|