| Plan Review Stops For Permit 05060552 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-06-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-26 |
Time |
16:55 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-06-26 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-03 |
Time |
08:58 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-08-03 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2005-08-03 00:00:00 | REVISED TO INCLUDE NEW ELECTRICAL RISER | | | DIAGRM FOR SPACE. | | | NEW ELECTRICAL ENGINEER OF RECORD. | | | LTR FROM ARCH RELEASING TO ENGINEER. | | | | | | | | | **DEWPEY'S PLAN REVIEW IN PROGRESS** |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-29 |
Time |
15:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-07-29 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2005-07-29 00:00:00 | *********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE SEE ORIGIANL PLANS | | | CAME IN SHOWING ELECTRICAL SERVICE AS | | | BEING EXSITING. PLEASE SEE PLANS AHVE | | | NOW COME BACK SHOWING A NEW 277/480V | | | DISCONNECT, TRANSFORMER AND PANELS. | | | PLEASE SEE UNDER FS 471.003 , 277/480V | | | SYSTEMS MUST BE SIGNED, DATED AND SEALED | | | BY A FLORIDA REGISTERED PE. | | | PLEASE BE SURE ALL PLANS CONTAIN ALL | | | TITLE BLOCK INFORMATION AS REQUIRED | | | UNDER FAC 61G15-23.002, FS 471.023 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-11 |
Time |
13:53 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-07-11 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-23 |
Time |
15:51 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-23 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2005-06-23 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE TWO ELECTRICAL SHEETS | | | WERE SUBMITTED. PLEASE SEE ONE SIGNED | | | DATED AND SEALED BY ARCH W/ A FEW NEW | | | RECEPTS, HOWEVER A PHOTOCOPY OF THE SAME | | | ARCH'S SIGNED, DATED AND SEALED PLAN WAS | | | ALSO SUBMITTED. PLANS MAY NOT BE | | | PHOTOCOPIED FROM ARCH SIGNED AND SEALED | | | PLANS. FS 481.221. | | | PLEASE SEE ALL PLANSSHALL BEAR AND | | | INDICATE THE PRINTED NAME AND SIGNATURE | | | OF HE PERSON RESPONSIBLE FOR PLANS AND | | | DESIGN. | | | FBC 104.2.1 | | | | | | 2)NOTE: PLEASE SEE 700.12E FOR | | | CIRCUITINGOF EM/EXT LTS. | | | | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-06-20 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-06-20 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2005-06-20 00:00:00 | 1. CONSTRUCTION, DEMOLITION, AND | | | RENOVATION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED THE SITE | | | DAILY. | | | | | | 3. SUFFICIENT EMERGENCY LIGHTS AND | | | EXIT SIGNS SHALL BE PROVIDED IN | | | SPACE. | | | | | | MIKE CARSILLO, FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-03 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-03 |
Time |
08:11 |
Sent To |
E |
|
| Notes |
| 2005-08-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-27 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-27 |
Time |
13:40 |
Sent To |
E |
|
| Notes |
| 2005-07-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-07 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-07 |
Time |
10:49 |
Sent To |
E |
|
| Notes |
| 2005-07-07 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-30 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-06-08 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2005-06-11 00:00:00 | COMM BOARD #22 | | 2005-06-08 00:00:00 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-30 |
Time |
12:21 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-30 |
Time |
12:21 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|