| Plan Review Stops For Permit 05060548 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-08 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-08 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-02 |
Time |
11:48 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-02 |
Time |
11:47 |
Sent To |
PC |
|
| Notes |
| 2005-07-02 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PROVIDE ANCHORING INFORMATION TO | | | COMPLY WITH FBC1606.1.3; STRUCTURAL | | | MEMBERS AND SYSTEMS, AND COMPONENTS AND | | | CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED | | | OVERTURNING, UPLIFT AND SLIDING AND TO | | | PROVIDE CONTINUOUS LOAD PATHS FOR THESE | | | FORCES TO THE FOUNDATION.WHERE A | | | PORTION OF THE RESISTANCE TO THESE | | | FORCES IS PROVIDED BY DEAD LOAD, THE | | | MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | | DURING A DESIGN WIND EVENT SHALL BE | | | USED. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-22 |
Time |
15:52 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-07-22 |
Time |
15:48 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-24 |
Time |
16:55 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-06-24 |
Time |
16:53 |
Sent To |
M |
|
| Notes |
| 2005-06-24 00:00:00 | | | | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} SUBMIT A SITE PLAN INDICATING THE | | | PHYSICAL LOCATION OF THE EQUIPMENT. | | | | | | 2} INDICATE THE PRIME MOVER, GAS OR LP. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-20 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-20 |
Time |
16:14 |
Sent To |
E |
|
| Notes |
| 2005-07-20 00:00:00 | TO "BTROBAUG" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-12 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-12 |
Time |
13:46 |
Sent To |
Z |
|
| Notes |
| 2005-07-12 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-22 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-22 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
| 2005-06-22 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-21 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-08 |
Time |
10:49 |
Sent To |
Z |
|
| Notes |
| 2005-06-08 00:00:00 | TO 'Z' BOX. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-20 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-20 |
Time |
12:37 |
Sent To |
I |
|
| Notes |
| 2005-07-20 00:00:00 | MUST PROVIDE A 4FT HIGH BUFFER AROUND | | | GENERATOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-21 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-21 |
Time |
10:08 |
Sent To |
I |
|
| Notes |
| 2005-06-21 00:00:00 | DENIED, | | | 1. MUST PROVIDE A HOMEOWNER ASSOCIATION | | | APPROVAL FOR THE GENERATOR. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|