| Plan Review Stops For Permit 05060463 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-02-07 |
Time |
08:01 |
Rev Time |
0.40 |
| Received By |
jgomez |
Date |
2006-02-07 |
Time |
08:01 |
Sent To |
PC |
|
| Notes |
| 2006-02-07 00:00:00 | ENERGY CALCULATIONS AND BLDG REVISIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-12-07 |
Time |
17:51 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-12-07 |
Time |
17:51 |
Sent To |
PC |
|
| Notes |
| 2005-12-07 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- ENERGY CALCULATIONS SUBMITTED ARE FBC | | | 2004 FORMS. NEED TO PROVIDE FBC 2001 | | | FORMS, SINCE PLANS WERE REVIEWED UNDER | | | FBC 2001. | | | | | | 2- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL AS REQUIRED BY RULE 9B-72 FOR | | | ATRIUM DOOR. SEE PLANS FOR SIZE AND | | | SWING DIRECTION OF DOOR. | | | | | | 3- OWES $70.00 FOR REVISION FEES. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-22 |
Time |
14:49 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-09-22 |
Time |
14:49 |
Sent To |
PC |
|
| Notes |
| 2005-09-22 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | | 1- ACCORDING TO ROBIN FROM KENCO | | | COMMUNITIES THE ENERGY CALCS WILL BE | | | RE-REVISED AGAIN TO HOUSE SPECIFIC | | | ORIENTATION. RE-RESUBMIT ENERGY CALCS. | | | | | | 2- REVISE ROOF FRAMING PLAN BY THE ENTRY | | | PORCH AREA. CONCRETE BEAM DOESN'T EXTEND | | | BACK TO THE FOYER AREA. ALSO, THERE IS | | | NOT CONCRETE BEAM BY KNEEWALL AREA. | | | REVISE AND SPECIFY CORRESPONDING TRUSS | | | CONECTORS. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 3- TRUSS ANCHOR SCHEDULE: REVISE # OF | | | NAILS FOR HUS26. SEE 2005 CATALOGUE. | | | | | | 4- WINDOW MULLION SPECIFIED FOR FIXED | | | WINDOWS DOESN'T RESIST THE DESIGN | | | PRESSURES. RE-REVISED AS REQUIRED AND | | | SPECIFY CORRESPONDING CONNECTORS. | | | | | | 5- PROVIDE PRODUCT APPROVAL FOR: | | | A) 1HR FIRE RATED INSWING DOOR AS SHOWN | | | ON PLANS. | | | | | | B) RE-REVISED WINDOW MULLION SIZE | | | SPECIFIED FOR GREAT ROOM. | | | | | | ***NOTE: REVISION FEES WILL APPLY. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-07-01 |
Time |
13:37 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-07-01 |
Time |
13:36 |
Sent To |
PC |
|
| Notes |
| 2005-07-01 00:00:00 | BUILDING REVIEW PROVISO: | | | 1- PROVIDE THE REVISED ENERGY | | | CALCULATIONS FOR WORST CASE SCENARIO. | | | 2- SHUTTERS UNDER A SEPARATE PERMIT. | | | 3- ROOF FRAMING PLAN: REVISE CONNECTOR | | | SPECIFIED AT FRONT PORCH MASONRY BEAMS. | | | NEED MASONRY CONNECTOR. SEE DETAILS 4/D1 | | | AND 5/D1 AND REVISE AS REQUIRED. | | | 4- TRUSS ANCHOR SCHEDULE: REVISE NAIL | | | SIZE FOR HUS26. SEE CATALOGUE. | | | 5- PROVIDE PRODUCT APPROVAL FOR: | | | A) 1 HR FIRE RATED DOOR & EGRESS | | | ASSEMBLY. | | | B) FIXED WINDOWS NEED FLORIDA PRODUCT | | | APPROVAL COVER PAGE. | | | C) SINGLE HUNG WINDOWS NEED FLORIDA | | | PRODUCT APPROVAL COVER PAGE. | | | D) ROOF TILE NEEDS MATCHING FLORIDA | | | PRODUCT APPROVAL. | | | E) WINDOW MULLIONS FOR FIXED WINDOWS: | | | CLEARLY SPECIFY SIZE OF MULLION AND | | | ANCHOR TO BE USED AT GREAT ROOM FIXED | | | WINDOW TO MEET THE DESIGN PRESSURES | | | CALCULATED ON PLANS. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 6- PROVIDE CLEAR WINDOW & DOOR SCHEDULES | | | WITH SIZES MATCHING PLANS. SYMBOLS TO | | | MATCH ALSO. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-13 |
Time |
20:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-13 |
Time |
20:11 |
Sent To |
PC |
|
| Notes |
| 2006-03-13 00:00:00 | *** REDLINED : VIF THE OCP FOR CU #1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-17 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-17 |
Time |
12:29 |
Sent To |
PC |
|
| Notes |
| 2006-01-17 00:00:00 | REDLINED. | | | | | | PLANS INDICATE THE POWDER RM AS CIRCUIT | | | #38, HOWEVER #38 ON PANEL SCHEDULE IS | | | MASTER BEDRM. | | | PLEASE SEE 210.1C3 WHICH REQUIRES A MIN | | | OF 20A #12 FOR BATH RECEPT(S). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-15 |
Time |
16:16 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-15 |
Time |
16:16 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-10 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-10 |
Time |
10:28 |
Sent To |
E |
|
| Notes |
| 2006-03-10 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-03 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-03 |
Time |
15:53 |
Sent To |
B |
|
| Notes |
| 2006-02-03 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-06 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-06 |
Time |
09:52 |
Sent To |
E |
|
| Notes |
| 2006-01-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-19 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-19 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2005-10-19 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-24 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-24 |
Time |
18:28 |
Sent To |
B |
|
| Notes |
| 2005-08-24 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-15 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-15 |
Time |
14:12 |
Sent To |
E |
|
| Notes |
| 2005-06-15 00:00:00 | TO RES RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-07 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-07 |
Time |
13:11 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-17 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-17 |
Time |
18:10 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-18 |
Time |
08:48 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-06-18 |
Time |
08:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-14 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-14 |
Time |
17:56 |
Sent To |
I |
|
| Notes |
|
|