Plan Review Details - Permit 05060459
Plan Review Stops For Permit 05060459
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-02-07 Cont ID  
Sent By jgomez Date 2006-02-07 Time 10:45 Rev Time 0.40
Received By jgomez Date 2006-02-07 Time 10:23 Sent To PC
Notes
2006-02-07 00:00:00ENERGY CALCS AND ATRIUM DOOR REVISION
 AND PRODUCT APPROVAL.
 NEED TO APPLY FOR STORM SHUTTERS PERMIT
 AS AGREED ON PROVISO..

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-12-06 Cont ID  
Sent By jgomez Date 2005-12-06 Time 14:32 Rev Time 0.75
Received By jgomez Date 2005-12-06 Time 14:32 Sent To PC
Notes
2005-12-06 00:00:00BUILDING REVIEW CHECKLIST:
 1- ENERGY CALCULATIONS SUBMITTED ARE
 USING FBC 2004 FORM. NEED ENERGY
 CALCULATIONS USING FBC 2001 FORM SINCE
 THAT WAS THE CODE PLANS WERE REVIEWED
 FOR.
  
 2- APPLY FOR SHUTTERS UNDER A SEPARATE
 PERMIT AS AGREED ON PROVISO. APPLY EARLY
 TO AVOID DELAYS OR CONFLICTS GIVEN THE
 LARGE VOLUME OF PERMIT APPLICATIONS THE
 CITY IS RECEIVING.
  
 3- PROVIDE PRODUCT APPROVAL FOR ATRIUM
 DOOR THAT MATCHES SPECIFICATIONS ON
 PLANS. SEE PLANS FOR SIZE AND SWING OF
 DOOR.
  
 4- OWES $70.00 FOR REVISION FEES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-09-22 Cont ID  
Sent By jgomez Date 2005-09-22 Time 16:18 Rev Time 0.50
Received By jgomez Date 2005-09-22 Time 16:18 Sent To PC
Notes
2005-09-22 00:00:00BUILDING SUBMITTAL CHECKLIST:
 1- ACCORDING TO ROBIN FROM KENCO
 COMMUNITIES THE ENERGY CALCS WILL BE
 RE-REVISED AGAIN TO SHOW HOME SPECIFIC
 ORIENTATION. RE-RESUBMIT REVISED ENERGY
 CALCULATIONS.
  
 2- NEED TO APPLY FOR SHUTTERS PERMIT.
  
 3- REVISE ROOF FRAMING PLAN BY THE ENTRY
 PORCH. CONCRETE BEAM DOESN'T EXTEND ALL
 THE WAY BACK TO THE FOYER AREA. ALSO,
 KNEEWALL AREA DOESN'T HAVE CONCRETE
 BEAMS EITHER. REVISE AS REQUIRED AND
 SPECIFY CORRESPONDING TRUSS CONNECTORS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 4- TRUSS ANCHOR SCHEDULE: REVISE NUMBER
 OF NAILS FOR HUS26. SEE 2005 CATALOGUE.
  
 5- WINDOW MULLION SPECIFIED FOR GREAT
 ROOM FIXED WINDOWS DON'T RESIST THE
 DESIGN PRESSURES. RE-REVISE AS REQUIRED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 6- PROVIDE PRODUCT APPROVAL FOR:
 A) 1 HR FIRE RATED INSWING DOOR AS SHOWN
 IN ATRIUM PLANS.
  
 B) WINDOW MULLION SPECIFIED FOR GREAT
 ROOM FIXED WINDOWS AS RE-REVISED BY THE
 ARCHITECT.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-07-19 Cont ID  
Sent By jgomez Date 2005-07-19 Time 11:34 Rev Time 2.00
Received By jgomez Date 2005-07-19 Time 11:34 Sent To PC
Notes
2005-07-18 00:00:00BUILDING REVIEW PROVISO:
 1- SHUTTERS UNDER A SEPARATE PERMIT.
 2- NEED WORST CASE SCENARIO ENERGY CALCS
 3- ROOF FRAMING PLAN: REVISE CONNECTOR
 SPECIFIED AT FRONT PORCH TO MATCH
 DETAILS 4/D1 AND 5/D1.
 4- REVISE NAIL SIZE FOR HUS26 CONNECTOR.
 5- SPECIFY SIZE AND ANCHORS FOR LARGE
 FIXED WINDOWS MULLION AT GREAT ROOM.
 6- RE-SUBMIT PRODUCT APPROVAL FOR:
 A) 1 HR FIRE RATED ATRIUM DOOR ASSEMBLY.
 B) FIXED WINDOWS.
 C) SINGLE HUNG WINDOWS.
 D) ROOF TILE.
 E) LARGE WINDOW MULLION AT GREAT ROOM.
 7- PROVIDE CLEAR DOOR AND WINDOW
 SCHEDULE. SYMBOLS USED FOR DOORS AND
 WINDOWS ARE MIXED TOGETHER.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-03 Cont ID  
Sent By dpalmer Date 2006-02-03 Time 17:44 Rev Time 0.00
Received By dpalmer Date 2006-02-03 Time 17:44 Sent To PC
Notes
2006-02-03 00:00:00 
  
 PLEASE SEE MIN GRND ROD 8' PER
 250.52A5

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-06-15 Cont ID  
Sent By dpalmer Date 2005-06-15 Time 16:22 Rev Time 0.30
Received By dpalmer Date 2005-06-15 Time 16:22 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-02-06 Cont ID  
Sent By adarroug Date 2006-02-06 Time 09:40 Rev Time 0.00
Received By adarroug Date 2006-02-06 Time 09:40 Sent To B
Notes
2006-02-06 00:00:00TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-27 Cont ID  
Sent By adarroug Date 2006-01-27 Time 15:52 Rev Time 0.00
Received By adarroug Date 2006-01-27 Time 15:52 Sent To E
Notes
2006-01-27 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-10-19 Cont ID  
Sent By adarroug Date 2005-10-19 Time 08:55 Rev Time 0.00
Received By adarroug Date 2005-10-19 Time 08:55 Sent To B
Notes
2005-10-19 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-24 Cont ID  
Sent By adarroug Date 2005-08-24 Time 10:24 Rev Time 0.00
Received By adarroug Date 2005-08-24 Time 10:24 Sent To B
Notes
2005-08-24 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-15 Cont ID  
Sent By shill Date 2005-06-15 Time 13:42 Rev Time 0.00
Received By shill Date 2005-06-15 Time 13:42 Sent To E
Notes
2005-06-15 00:00:00TO RES RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-19 Cont ID  
Sent By shill Date 2005-07-19 Time 11:52 Rev Time 0.00
Received By jgomez Date 2005-06-08 Time 11:56 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-06-17 Cont ID  
Sent By hmoser Date 2005-06-17 Time 17:20 Rev Time 0.00
Received By hmoser Date 2005-06-17 Time 17:02 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-06-18 Cont ID  
Sent By jleech Date 2005-06-18 Time 09:53 Rev Time 0.25
Received By jleech Date 2005-06-18 Time 09:53 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-06-14 Cont ID  
Sent By jgomez Date 2005-07-19 Time 11:52 Rev Time 0.00
Received By mmclean Date 2005-06-14 Time 18:26 Sent To I
Notes
***NONE***