| Plan Review Stops For Permit 05060430 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-07-19 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-11-16 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-16 |
Time |
10:13 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2005-11-16 |
Time |
10:13 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-27 |
Time |
13:36 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-08-27 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2005-08-27 00:00:00 | PLANS APPEAR TO BE CODE COMPLIANT, I | | | RECEIVED AN E-MAIL FROM DEAN LAUDERMILK, | | | THERE SEEMS TO BE ISSUES ABOUT EASEMENTS | | | THAT HAVE NOT BEEN APPROVED BY THE LAW | | | DEPARTMENT. JIM WITMER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-19 |
Time |
11:09 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-07-19 |
Time |
11:03 |
Sent To |
PC |
|
| Notes |
| 2005-07-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05060430 | | | ADD: 7500 NORTHLAKES BLVD | | | CONT: METRO EQUIPMENT SERVICES | | | TEL: (305)586-8925 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) METRO EQUIPMENT SERVICES TO PROVIDE | | | STATE LICENSE NUMBER FL S S 489. | | | | | | 2) PLANS INDICATE A PRE-MANUFACTURED | | | CONTROL BUILDING, PROVIDE STATE | | | APPROVED PLANS BY THE DEPARTMENT OF | | | COMMUNITY AFFAIRS.FL S S 553.1 RULE B-1. | | | | | | 3) DEPENDING ON THE STATE APPROVAL FOR | | | THE MANUFACTURED BUILDING, PRODUCT | | | APPROVALS MAY BE REQUIRED FOR THE DOORS | | | AND VENTS. | | | | | | 4) STATE APPROVED PLANS SHALL INDICATE: | | | FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 5) THIS STRUCTURE IS IN A "A" FLOOD ZONE | | | | | | THE FLOOD HEIGHT HAS NOT BEEN | | | DETERMINED, HAS THE BASE FLOOD HEIGHT | | | FOR THE CONTROL BUILDING BEEN | | | CONSIDERED? | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-12 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-11 |
Time |
19:49 |
Sent To |
PC |
|
| Notes |
| 2006-09-12 00:00:00 | REV FOR MOVING THE ANT, AND PROVIDING | | | LOAD TESTING. | | 2006-09-11 00:00:00 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-26 |
Time |
19:51 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-08-26 |
Time |
19:51 |
Sent To |
|
|
| Notes |
| 2005-08-26 00:00:00 | NEEDS 2ND SET OF GENERATORS SPEC/CUT | | | SHEETS. | | | ONLY ONE SET SUBMITTED. | | | STAMPED ELECTRICAL PLANS AND ONE SET OF | | | GEN SPECS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-23 |
Time |
15:01 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-06-23 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2005-06-23 00:00:00 | ************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE MISSING TITLE BLOCK | | | AND TITLE BLOCK INFORMATION AS REQUIRED | | | UNDER FAC 61G15-23.002, FS 471.023. | | | PLEASE SEE THIS IS REQUIRED FOR ALL | | | SHEETS AND FOR ALL TRADES WHEATHER OR | | | NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | | | | 2)NOTE: PLEASE COMPLETE ELECTRICAL | | | PLANS. PLEASE SEE NO SEC'S, FEEDER SIZES | | | ARE INDICATED. THERE APPEARS TO BE | | | NOTS/NUMBERS TO EACH, HOWEVER THERE IS | | | NO FEEDER SCHEDULE TO CORRELATE. | | | 215.5,310.16,240.4 ETC | | | | | | 3)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH A PANEL | | | SCHEDULE TO BE SUBMITTED.NO PANEL | | | SCHEDULE SUBMITTED. | | | 215.5 | | | | | | 4)NOTE: PLEASE SUBMIT MANUFACTURE | | | SPECS/CUT SHEETS FOR GENERATOR AND ATS | | | SWITCH. THESE ARE TO SHOW ALL LISTINGS | | | PER A NRTL. | | | PLEASE ALSO SEE MECH/FIRE REVIEW | | | COMMENTS, AS SPECS ETC MAY BE REQUIRED | | | ALSO FOR FUEL TANK. | | | | | | 5)NOTE: PLEASE SEE PERMIT APPLICATION | | | WAS SUBMITTED FOR $1.7 MIL SCOPE OF WORK | | | AND NOW INDICATES $250K?? PLEASE SUBMIT | | | ONLY PLANS FOR SCOPE OF WORK PROPOSED. | | | IF WORL IN THIS SCOPE IS FOR BLDG ONLY, | | | THNE PLAN REVISE PERMIT APPLICATION AND | | | SUBMIT PLANS FOR BLDG ONLY. | | | 215.5 | | | | | | 6)NOTE: PLEASE SEE 250.50 FOR MIN | | | REQUIRED GROUNDING ELECTRODE SYSTEM. | | | NO DETAIL PROVIDED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-06-14 |
Time |
15:22 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-06-14 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2005-06-14 00:00:00 | PASSED: | | | | | | 1. REVIEWED FOR THE PORTION THAT IS | | | LOCATED ON CITY PROPERTY.PER DEAN | | | RUNNELS, PERMIT WILL BE ISSUED FOR THAT | | | PORTION ONLY. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-09-01 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-09-01 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2005-09-01 00:00:00 | OK - PLEASE SEE COMMENTS REGARDING 2ND | | | SET OF GENERATOR SPECIFICATIONS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-06-30 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-06-30 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2005-06-30 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE SEE OTHER REVIEW COMMENTS IN | | | REGARDS TO FS AND FAC REQUIREMENTS. | | | | | | 2) PLEASE PROVIDE CLARIFICATION FOR | | | SCOPE OF WORK AS IT APPLIES TO THE | | | PERMIT APPLICATION. | | | | | | 3) IS THERE ANY EMERGENCY VEHICLE ACCESS | | | TO ANY STRUCTURE OR FUEL TANK OTHER THAN | | | NORTHLAKE BLVD? | | | | | | 4) PLEASE PROVIDE CUT SHEETS FOR FUEL | | | TANK AND PRODUCT. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 805-6722 OR 835-2951 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-05 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-05 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2006-10-05 00:00:00 | GAS REVISION OK - CHANGED LOCATION OF | | | VALVES, GUAGES, FLEX HOSE CONNECTIONS | | | ETC. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-06 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-06 |
Time |
15:02 |
Sent To |
E |
|
| Notes |
| 2006-09-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-14 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-14 |
Time |
11:12 |
Sent To |
Z |
|
| Notes |
| 2005-11-14 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-10 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-10 |
Time |
16:42 |
Sent To |
P |
|
| Notes |
| 2005-11-10 00:00:00 | TO "PSCHMITZ" DESK/AS PER "JWITMER" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-19 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-19 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2005-08-22 00:00:00 | TO "COMM" BD#41 | | 2005-08-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-19 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-06-08 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | MOVED TO BD#6 ADARROUGH | | 2005-06-10 00:00:00 | COMM BOARD #60 | | 2005-06-08 00:00:00 | ON THE TABLE WAITING TO GO ON COMM | | | BOARD. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-22 |
Time |
16:07 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-07-22 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2005-07-22 00:00:00 | PER MEETING W/DESIGN GROUP - UNDERGROUND | | | LP TANK (500 GALLON) - APPROVED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-12 |
Time |
11:58 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-07-12 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | PLAN DOES NOT INDICATE DISTANCE FROM THE | | | UNDERGROUND LP TANK TO THE PROPERTY | | | LINE.SHOW COMPLIANCE WTIH NFPA 58. | | | GENERATOR ROOM INDICATED ON PLAN SHEET | | | S7 IS CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-11-14 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-11-14 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-08-28 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-08-28 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-08-28 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2005-08-28 00:00:00 | PAUL SCHMITZ, PLUMBING & GAS PLANS | | | EXAMINER561-805-6692 | | | | | | [email protected] | | | GAS PLAN REVIEW FBC 2001 | | | DENIED | | | 1. ONLY ONE SET OF GENERATOR | | | SPECIFICATIONS SUBMITTED. | | | 2.PLEASE ADDRESS COMMENTS BY OTHER PLAN | | | REVIEWERS. | | | END OF COMMENTS | | | | | | DENIED | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-06 |
Time |
18:22 |
Rev Time |
0.60 |
| Received By |
kstevens |
Date |
2005-07-06 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2005-07-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | | | | A. SUBMIT THE FOLLOWING INFORMATION FOR | | | THE GAS PIPING PERMIT: | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | 2. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2001 FUEL GAS CODE SECS. 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU | | | 402(34). | | | 3. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | 4. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | 5. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | 6. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 7. WELDING CERTIFICATIONS, PICTURE I.D., | | | AND WELDING PROCEDURE REQUIRED AT TIME | | | OF GAS PERMIT APPLICATION. SEPARATE GAS | | | PERMIT REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-11-15 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-11-15 |
Time |
17:30 |
Sent To |
B |
|
| Notes |
| 2005-11-15 00:00:00 | OK TO APPROVE PER GRACE JOYCE, A | | | RESOLUTION WAS APPROVED FOR THE PROPSED | | | PROJECT, RESOLUTION NUMBER 385-05 | | | 10/24/05 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2005-09-01 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
gjoyce |
Date |
2005-09-01 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2005-10-13 00:00:00 | AGREEMENT TO BE SIGNED BY CIY AT | | | COMMISSION ON MONDAY OCT 24TH OK TO | | | APPROVE ON TUESDAY OCTOBER 25TH. | | 2005-09-01 00:00:00 | NEEDS EASEMENT FROM CITY PER AJVANN |
|
|