| Plan Review Stops For Permit 05060379 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-01-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-01-19 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-01-19 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2006-01-19 00:00:00 | RE-STAMP PLANS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-17 |
Time |
10:22 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2006-01-17 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2006-01-17 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)THE SEAL IS TO BE DATED, | | | FAC61G15-23.002. | | | | | | 2.)THE CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR EL-SID ENGINEERING IS TO BE | | | ON EACH SHEET, FAC61G15-23.002.SITE | | | PLAN. | | | | | | 3.)THE SHEETS SUBMITTED DO NOT MATCH | | | THE PERMITTED SET.A RESTAMP MUST | | | EXACTLY MATCH THE PERMITTED SET.IF | | | THIS IS NOT POSSIBLE, REVIEWS BY ALL | | | TRADES REQUIRED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-04 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-04 |
Time |
14:44 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-02 |
Time |
11:09 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-02 |
Time |
11:09 |
Sent To |
PC |
|
| Notes |
| 2005-07-02 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)TITLE BLOCK TO COMPLY WITH | | | FAC61G15-23.002.CERTIFICATE OF | | | AUTHORIZATION NUMBER TO BE ON THE TITLE | | | BLOCK. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-18 |
Time |
08:56 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-08-18 |
Time |
08:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-22 |
Time |
09:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-22 |
Time |
09:24 |
Sent To |
P |
|
| Notes |
| 2005-07-22 00:00:00 | | | | | | | SAME COMMENT AS PREVIOUS REVIEW. THIS | | | PERTAINS TO THE ELECTRICAL PANEL SHOWN | | | ON THE ELECTRICAL SCHEMATIC. | | | PLEASE SUBMIT DETAILS FOR THE PANEL | | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDU | | | IT SIZE AND TYPE, PANEL RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-14 |
Time |
17:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-14 |
Time |
17:45 |
Sent To |
P |
|
| Notes |
| 2005-06-14 00:00:00 | | | | PLEASE SUBMIT DETAILS FOR THE PANEL | | | SHOWN ON THE SCHEMATIC, FEEDER AND | | | CONDUIT SIZE AND TYPE, PANEL RATING AND | | | OCP, PANEL SCHEDULE AND COMPUTED LOAD, | | | ETC. IF AN ELECTRIC HEATER IS TO BE | | | INSTALLEDPLEASE SUBMIT CALCULATIONS | | | FOR THE MAINSERVICE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-17 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-17 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2006-01-17 00:00:00 | TO "SHILL" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-17 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-17 |
Time |
12:35 |
Sent To |
E |
|
| Notes |
| 2005-08-17 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-21 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-21 |
Time |
15:32 |
Sent To |
E |
|
| Notes |
| 2005-07-21 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-14 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-14 |
Time |
13:38 |
Sent To |
E |
|
| Notes |
| 2005-06-14 00:00:00 | TO ELEC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-07 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-07 |
Time |
10:56 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-04 |
Time |
10:58 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-08-04 |
Time |
10:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-21 |
Time |
14:45 |
Rev Time |
0.56 |
| Received By |
kstevens |
Date |
2005-06-21 |
Time |
14:45 |
Sent To |
B |
|
| Notes |
| 2005-06-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2001 CHAPTER 1 | | | | | | 1. PIPING SCHEMATIC SHOWS A CLEANING | | | LINE AND A POOL HEATER THAT ARE NOT | | | SHOWN ON THE POOL DATA & EQUIPMENT | | | SECTION. PLEASE CORRELATE. SECTION | | | 104.2.1. | | | 2. THE ENGINEER SHALL LEGIBLY INDICATE | | | THEIR NAME ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. SOME SHEETS DO | | | NOT HAVE THE NUMBER AND SOME SHEETS THE | | | NUMBER IS NOT LEGIBLE. FAC | | | 61G15-23.002(2) AND FS 471.025. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-13 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-13 |
Time |
18:21 |
Sent To |
I |
|
| Notes |
|
|