| Plan Review Stops For Permit 05051931 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-02-27 |
Time |
14:48 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-02-27 |
Time |
14:48 |
Sent To |
M |
|
| Notes |
| 2006-02-27 00:00:00 | 2X WINDOW MULLIONS AND EXERCISE ROOM | | | REVISION. JG. | | | FIREPLACE SPECS SENT TO MECHANICAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-11-17 |
Time |
17:51 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2005-11-17 |
Time |
17:51 |
Sent To |
PC |
|
| Notes |
| 2005-11-17 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO | | | (PROVIDE THE FOLLOWING INFORMATION PRIOR | | | TO INSTALLATION TO AVOID DELAYS OR | | | CONFLICTS): | | | 1- PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS, NON-IMPACT SLIDING GLASS | | | DOORS AND 2X WINDOW MULLIONSUNDER A | | | SEPARATE PERMIT AS AGREED WITH THE | | | CONTRACTOR. | | | | | | 2- PROVIDE COMPLETE SPECS AND UL LISTING | | | FOR TWO SIDED FIREPLACE AS SHOWN ON | | | PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-13 |
Time |
08:49 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-09-13 |
Time |
08:49 |
Sent To |
PC |
|
| Notes |
| 2005-09-13 00:00:00 | BUILDING REVIEW THIRD CHECKLIST: | | | 1- OPENINGS FROM THE GARAGE DIRECTLY | | | INTO A ROOM USED FOR SLEEPING PURPOSES | | | IS NOT ALLOWED. SEC. 411.2.8 FBC 2001. | | | "THEATER" ROOM NEXT TO THE GARAGE IS SET | | | UP AS A BEDRM. THERE IS A CLOSET IN THE | | | ROOM AND ELECTRICAL PLAN SHOWS SMOKE | | | DETECTORS IN AND OUT OF THE ROOM WHEN | | | REQUIRED FOR SLEEPING ROOMS. REVISE AS | | | REQUIRED. | | | | | | 2- NEED A COMPLETE BATHROOM WITH DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING AS | | | REQUIRED BY SEC. 11-11 FBC 2001. | | | | | | 3- PRODUCT APPROVALS FOR DOORS/WINDOWS | | | SUBMITTED ARE FOR IMPACT GLAZING. THIS | | | HOUSE IS SUPPOSED TO HAVE NON-IMPACT | | | GLAZING. PROVIDE CORRECT PRODUCT | | | APPROVAL FOR: | | | A) FRENCH DOORS. | | | B) FIXED WINDOWS. | | | C) SINGLE HUNG WINDOWS. | | | D) SLIDING GLASS DOORS | | | E) CASEMENT WINDOWS. | | | | | | 4- NEED TO SPECIFY SAFETY GLASS FOR | | | WINDOWS AT HER BATH BY THE WHIRPOOL. | | | SEC. 2405.2.1 FBC 2001. INFORMATION | | | SUBMITTED WAS FOR IMPACT GLASS. THAT'S | | | WHY THIS COMMENT WAS NOT ADDRESSED ON | | | PREVIOUS CHECKLIST. | | | | | | 5- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 6- PROVIDE COMPLETE SPECS FOR BBQ HOOD | | | FOR EXTERIOR USE AND SPECS FOR SPECIFIC | | | GRILL TO BE INSTALLED. | | | | | | 7- PROVIDE COPY OF PAID IMPACT FEES | | | RECEIPT THAT CORRESPONDS TO THIS HOUSE. | | | RECEIPT SUBMITTED IS FOR ANOTHER HOUSE. | | | | | | 8- A) PROVIDE COMPLETE UL LISTING AND | | | SPECS FOR TWO SIDED FIREPLACE AS SHOWN | | | ON PLANS. INFORMATION SUBMITTED DOESN'T | | | MATCH PLANS. | | | | | | B) PROVIDE COMBUSTION AIR CALCULATIONS | | | FOR VENTLESS FIREPLACE FOR MECHANICAL | | | PLANS EXAMINER REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-08-15 |
Time |
12:37 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-08-15 |
Time |
12:37 |
Sent To |
PC |
|
| Notes |
| 2005-08-15 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED RECORDED NOC. | | | | | | 2- A)PROVIDE COMPLETE SPECS AND APPROVED | | | LISTING FOR GRILL. INCLUDING MODEL, ETC. | | | B) PROVIDE COMPLETE SPECS AND APPROVED | | | LISTING FOR HOOD FOR OUTDOOR USE. | | | | | | 3- SLIDING GLASS DOORS: A) LOCAL PRODUCT | | | APPROVAL IS IN THE REVIEW PROCESS. | | | CONTACT LUIS MARTINEZ AT 805-6712. | | | B) PROVIDE COMPLETE PACKAGE. THERE ARE | | | SOME DRAWINGS THAT ARE MISSING. | | | | | | 4- A) SPECIFY SIZE OF MULLION FOR FIXED | | | WINDOWS AT DINING AREA TO VERIFY FOR | | | CALCULATED DESIGN PRESSURES COMPLIANCE. | | | B) PROVIDE PRODUCT APPROVAL FOR MULLION | | | SPECIFIED ABOVE. | | | | | | 5- SOIL TEST REPORT WAS NOT SUBMITTED. | | | | | | 6- OPENINGS FROM THE GARAGE DIRECTLY | | | INTO A ROOM USED FOR SLEEPING PURPOSES | | | IS NOT ALLOWED. SEC. 411.2.8 FBC 2001. | | | "THEATER" ROOM NEXT TO GARAGE IS SET UP | | | AS A BEDROOM ALSO. THERE IS A CLOSET AND | | | SMOKER DETECTORS REQUIRED FOR BEDROOMS. | | | REVISE AS REQUIRED. | | | | | | 7- OWES $912.89 FOR UPDATED VALUATION. | | | | | | 8- NEED A COMPLETE BATH WITH DOOR THAT | | | ALLOWS 29" MIN. CLEAR OPENING AS REQ'D | | | BY SEC. 11-11 FBC 2001. | | | | | | 9- PROVIDE COPY OF IMPACT FEES PAID | | | RECEIPT THAT MATCHES PR NUMBER STAMPED | | | ON PLANS. | | | | | | 10- PROVIDE LISTING AND SPECS FOR 2 | | | SIDED FIREPLACE AS SHOWN ON PLANS. ONE | | | SUBMITTED DOESN'T MATCH PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-07-11 |
Time |
11:26 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-07-11 |
Time |
11:26 |
Sent To |
Z |
|
| Notes |
| 2005-07-11 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED NOTICE OF COMMENCEMENT. | | | | | | 2- UPDATE GENERAL NOTES IN SHEET T1. SEE | | | CHAPTER 35 FOR PROPER REFERENCE AND | | | EDITION. | | | | | | 3- DESIGN PARAMETERS: WHY MINIMUM SOIL | | | BEARING PRESSURE IS NA?. | | | | | | 4- PROVIDE SPECIFICATIONS FOR COLUMNS AT | | | MASTER BEDROOM BAY WINDOW. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 5- PROVIDE COMPLETE SPECS AND LISTING | | | FOR BBQ TO BE INSTALLED IN PORCH. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001 | | | AND SECTION 2808 FBC 2001. | | | | | | 6- FOOTING DETAIL #5 DOESN'T MATCH | | | FOOTING BETWEEN GARAGE AND CLUB ROOM. | | | | | | 7- PLANS SUBMITTED ARE SPECIFYING LOT 3. | | | APPLICATION IS FOR LOT 20. REVISE PLANS. | | | | | | 8- REVISE/UPDATE ALL TRUSS ANCHORS | | | SPECIFYING SAME SIZE AND NUMBER OF NAILS | | | AS SHOWN ON CATALOGUE THAT WAS REVISED | | | TO COMPLY WITH SEC. 1609.4.3 FBC 2001. | | | OTHERWISE, PROVIDE TESTING & ENGINEERING | | | FOR NAIL SIZE AND NUMBER THAT DIFFER | | | FROM THOSE ALREADY TESTED AND PUBLISHED | | | BY THE MANUFACTURER. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 9- CONNECTOR THD210 IS A WOOD TO WOOD | | | CONNECTOR. SEE CATALOGUE FOR PROPER | | | MASONRY CONNECTOR. | | | | | | 10- DETAIL E/A3: CLARIFY WHY SPECIFYING | | | EXP. BOLTS INTO CONCRETE. THERE IS NOT | | | ATTACMENT TO CONCRETE. | | | | | | 11- CLEARLY SPECIFY MULLION SIZE AND | | | ANCHORS FOR BIG WINDOWS AT LIVING ROOM. | | | SEE PRODUCT APPROVAL TO VERIFY THAT | | | ANCHOR SIZE WILL MEET THE CALCULATED | | | DESIGN PRESSURES. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 12- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) SLIDING GLASS DOORS. FLORIDA APPROVAL | | | SUBMITTED DOESN'T MATCH DADE COUNTY NOA | | | SUBMITTED. | | | | | | B) FIXED WINDOWS. 2 DIFFERENT DADE | | | COUNTY NOA'S WERE SUBMITTED. SELECT ONLY | | | ONE. | | | | | | C) CASEMENT WINDOWS. NEED FLORIDA | | | PRODUCT APPROVAL. | | | | | | D) WINDOW MULLION FOR LIVING ROOM FIXED | | | WINDOWS. SPECIFY SIZE AND FASTENERS. | | | | | | 13- SOIL TEST REPORT SUBMITTED IS FOR | | | LOT 3. NEED ONE FOR LOT 20. | | | | | | 14- SURVEY DOESN'T MATCH PLANS. REVISE | | | AS REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT(561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-24 |
Time |
08:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-24 |
Time |
07:57 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-11 |
Time |
12:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-11 |
Time |
12:05 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-14 |
Time |
17:25 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-07-14 |
Time |
17:25 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-11 |
Time |
13:26 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-11 |
Time |
13:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-09 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-09 |
Time |
16:19 |
Sent To |
P |
|
| Notes |
| 2007-01-09 16:20:46 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-18 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-18 |
Time |
15:30 |
Sent To |
E |
|
| Notes |
| 2006-10-18 15:30:34 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-02 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-02 |
Time |
14:39 |
Sent To |
E |
|
| Notes |
| 2006-08-02 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-15 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-15 |
Time |
18:05 |
Sent To |
B |
|
| Notes |
| 2006-02-15 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-16 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-16 |
Time |
13:25 |
Sent To |
B |
|
| Notes |
| 2005-11-16 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-01 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-01 |
Time |
14:41 |
Sent To |
B |
|
| Notes |
| 2005-09-01 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-02 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-02 |
Time |
08:28 |
Sent To |
M |
|
| Notes |
| 2005-08-02 00:00:00 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-28 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-28 |
Time |
11:28 |
Sent To |
Z |
|
| Notes |
| 2005-07-28 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-12 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-09 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2005-06-09 00:00:00 | TO RES RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-12 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-27 |
Time |
15:53 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-02-27 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2006-02-27 00:00:00 | SUBMITTAL FOR FIRE PLACE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-02 |
Time |
10:27 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-08-02 |
Time |
10:29 |
Sent To |
B |
|
| Notes |
| 2005-08-02 00:00:00 | MECH. PLAN REVIEW: | | | | | | PROVISO:R/A REQUIRED OUT OF OPT. | | | GUEST SUITE. | | | | | | MECH. INSPECTOR TO CHECK AT TIME OF | | | ROUGH INSP. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-16 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-16 |
Time |
17:30 |
Sent To |
P |
|
| Notes |
| 2005-06-16 00:00:00 | PLAN DENIED | | | MECHANICAL PLAN AND FLOOR PLAN DO NOT | | | MATCH | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-02-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-01 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-01 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2007-02-01 10:12:42 | REVISED SANITARY RISER DIAGRAM OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-18 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-02 |
Time |
10:29 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-18 |
Time |
07:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-01 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-01 |
Time |
11:49 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-12 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-09 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | DENIED, | | | 1. PLANS AND SURVEY DOES NOT MATCH, | | | SURVEY SHOWS A LOT 30 AND PLANS FOR A | | | LOT AND APPLICATION SHOWS LOT 20. | | | 2. PLANS/SURVEY/APPLICATION/COMPUTER | | | SYSTEMS MUST SHOW THE SAME LOT. | | | 3. ZERO LOT MUST BE LOT APPROVED IN THE | | | MINOR AMENDMENT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | 2005-06-09 00:00:00 | ZONING TO REVIEW LAST. NEED GRACE | | | OPINION ON PERMIT |
|
|