| Plan Review Stops For Permit 05051869 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-26 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-07-26 |
Time |
15:11 |
Sent To |
PC |
|
| Notes |
| 2005-07-26 00:00:00 | OK PER LEA SMITH/JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-06-16 |
Time |
14:03 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-06-16 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2005-06-16 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | | | | 1. 104.6.5 BUILDING PERMIT VALUATION. IF | | | IN THE OPINION OF THE BUILDING OFFICIAL | | | THE CLAIMED VALUATION OF BUILDING, AL- | | | TERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS | | | TO BE UNDERESTIMATED ON THE APPLICATION, | | | THE PERMIT SHALL BE DENIED, UNLESS THE | | | APPLICANT CAN SHOW DETAILED ESTIMATES | | | AND/OR BONA FIDED SIGNED CONTRACTS (EX- | | | CLUDING LAND VALUE) TO MEET THE APPROVAL | | | OF THE BUILDING OFFICIAL. FOR PERMITTING | | | PURPOSES, VALUATION FOR BUILDINGS AND | | | SYSTEMS SHALL BE FOUND IN MARSHALL AND | | | SWIFT OR THE SOUTHERN BUILDING CODE | | | CONGRESS INTERNATIONAL VALUATION TABLES, | | | LATEST EDITION, AND SHALL BE BASED ON | | | TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHAN- | | | ICAL, INTERIOR FINISH, NORMAL SITE WORK | | | (EXCAVATION AND BACKFILL FOR BUILDINGS), | | | ARCHITECTURAL AND DESIGN FEES, OVERHEAD | | | AND PROFIT, EXCLUDING ONLY LAND VALUE. | | | | | | ADDITIONAL FEES OF $322.63 WILL BE DUE | | | AT TIME OF RESUBMITTAL. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 | | | | | | ACCORDING TO MARSHALL/SWIFT THE VALUE OF | | | THE PERMIT IS 25972. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-08 |
Time |
12:34 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-07-08 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-08 |
Time |
08:51 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-08 |
Time |
08:51 |
Sent To |
P |
|
| Notes |
| 2005-06-08 00:00:00 | ************ UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE WIRING DIAGRAM | | | INDICATES A NEW ELECTRICAL PANEL BEING | | | INSTALLED, HOWEVER NO INFORMATION IS | | | GIOVEN FOR NEW PANEL. | | | PLEASE INDICATE SIZE, FEEDERS, CONDUITS, | | | OCP FROM EXISTING ETC. | | | | | | 2)NOTE: PLEASE SEE BLDG COMNMENTS FOR | | | VALUATION OF PERMIT APPLICATION. PLEASE | | | SEE APPPLICATION SHOWS $10K. PLEASE SEE | | | FBC 104.6.5. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-07 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-07 |
Time |
11:26 |
Sent To |
E |
|
| Notes |
| 2005-07-07 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-06 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-06 |
Time |
15:08 |
Sent To |
E |
|
| Notes |
| 2005-06-06 00:00:00 | TO 'E' BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
09:19 |
Sent To |
Z |
|
| Notes |
| 2005-06-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-19 |
Time |
14:29 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-07-19 |
Time |
14:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-15 |
Time |
15:43 |
Rev Time |
0.55 |
| Received By |
kstevens |
Date |
2005-06-15 |
Time |
15:43 |
Sent To |
B |
|
| Notes |
| 2005-06-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | 1. FBC-2001424.2.6.6.2 SHOW COMPLIANCE | | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUF INFO FOR VAC LOCK. | | | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) | | | 2. FBC-2001424.2.6.6.5 WHERE PROVIDED, | | | THE VACUUM OR PRESSURE CLEANER FITTING | | | SHALL BE LOCATED AT LEAST 6" AND NOT | | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | | THE SKIMMER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-03 |
|
|
Cont ID |
|
| Sent By |
ebowers |
Date |
2005-06-03 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
ebowers |
Date |
2005-06-03 |
Time |
11:53 |
Sent To |
I |
|
| Notes |
|
|