Plan Review Details - Permit 05051850
Plan Review Stops For Permit 05051850
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-02-03 Cont ID  
Sent By jwitmer Date 2006-02-03 Time 16:18 Rev Time 0.77
Received By jwitmer Date 2006-02-03 Time 16:18 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-12-08 Cont ID  
Sent By jwitmer Date 2005-12-08 Time 07:51 Rev Time 1.11
Received By jwitmer Date 2005-12-08 Time 07:51 Sent To PC
Notes
2005-12-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05051850
 ADD: 600 NORTH POINT
 CONT: SIGN LANGUAGE
 TEL: (800)846-2255 EXT 1367
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 3RD REVIEW
 ACTION: DENIED
  
  
 1) THE PLAN SUBMITTALS APPEAR TO HAVE A
 SURVEY AND A SITE PLAN:
  
 1A) SURVEY, THE SURVEY APPEARS TO BE A
 COPY MANY PLACES ON THE SURVEY IT READS
 THIS IS A SURVEY OR THIS SURVEY IS
 RECERTIFIED.THE SURVEY WILL NOT BE
 REQUIRED IF THE SITE PLAN SUBMITTED HAS
 CORRECTIONS MADE.
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 1B) SITE PLAN:
 1B(1) THE SITE PLAN SUBMITTED IS A COPY,
 NO RAISED SEALS FROM THE DESIGN
 PROFESSIONAL. WHEN PBSJ, POST,BUCKLEY,
 SCHUH & JERNIGAN INC NAMES APPEAR ON THE
 HEADER STRIP THIS REQUIRES SEALED PLANS.
 1B(2) IF THE NAMES MENTIONED ABOVE ARE
 NOT ON THE HEADER STRIP WE DO NOT THEN
 HAVE TO MEET THIS OBLIGATION, BUT UNDER
 FBC 104.2.1*ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS & ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. NOTE!!!! I AM NOT REQUESTING YOU
 TO SIDE STEP COPYRIGHT LAWS BUT IF
 SOMEONE DOES THIS, THEY THEN HAVE TO
 TAKE RESPONSIBILITY FOR THE DRAWINGS.
  
 1C) COMPILE THE PLANS INTO 2 COMPLETE
 PACKAGES, REMOVE THE EXCESS PAPER NOT
 REQUIRED FOR REVIEW. EXAMPLETHERE IS
 SITE PLANS WITH PBSJ AND SITE PLANS
 WITHOUT THIS HEADING BUT NO ONE TAKES
 RESPONSIBLITY FOR THE DRAWING? MAKE (2)
 SETS OF PLANS TO BE REVIEWED!!!!!
  
 1D) THERE ARE ENGINEERED PLANS FROM
 GLEN TISDALE (2) SETS EACH DESIGNED
 UNDER THE 2001 FL BLDG CODE AND (2) SETS
  
 UNDER THE 2004 FL BLDG CODE, REMOVE THE
 2004 SINCE THIS PERMIT WAS FILED UNDER
 THE 2001 FL BLDG CODE.
  
 2) THE NOTICE OF COMMENCEMENT HAS NEVER
 BEEN FILED AT THE CLERK OF THE COURT.
 THE COUNTY STAMP FROM THE CLERK OF THE
 COURT MUST BE ON THE NOC AND THE DATE
 RECORDED, WORK MUST START WITHIN 90 DAYS
 OF THE RECORDED DATE OR THE NOC MUST BE
 REFILED. FL S S 713.13.
  
 3) PREVIOUSLY CONTRACTOR HAD GIVEN US
 THE VALUE OF THE PROJECT AS $16,000.00
 DOLLARS SEE ATTACHMENT FOR BALANCE DUE.
  
 4) REQUIRES THE ORIGINAL PERMIT
 APPLICATION OR A NEW APPLICATION WITH
 SIGNATURES SHALL BE REQUIRED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-09-20 Cont ID  
Sent By jwitmer Date 2005-09-20 Time 14:02 Rev Time 1.22
Received By jwitmer Date 2005-09-20 Time 14:01 Sent To PC
Notes
2005-09-20 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05051850
 ADD: 600 NORTH POINT
 CONT: SIGN LANGUAGE
 TEL: (800)846-2255 EXT 1367
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 1) SITE PLANS ARE COPIED, SEE
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 2) SEE ELECTRICAL COMMENTS ABOUT
 ENGINEERED PLANS TITLEBLOCK INFORMATION
 REQUIRED ON PLANS. FAC 61G15-23.002 &
 FL S S 471.023
  
 3) PERMIT APPLICATION VALUE IS STATED AS
  
 $2,000.00 WILL BE CALCULATED USING
 MARSHAL & SWIFT VALUES.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-09 Cont ID  
Sent By lsmith Date 2005-06-09 Time 10:50 Rev Time 0.50
Received By lsmith Date 2005-06-09 Time 10:50 Sent To  
Notes
2005-06-09 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1.NEW SIGN IS A DIFFERENT SHAPE. MUST BE
 A NEW CABINET. NOT JUST A FACE CHANGE.
  
 2.SUBMIT ENGINEERED PLANS TO SHOW
 COMPLIANCE WITH WIND DESIGN 140 MPR.
  
 3.ACCORDING TO 104.2.1 DRAWINGS MUST
 SHOW THE NAME OF THE PERSON RESPONSIBLE
 FOR THE DRAWING.
  
 4.PER FBC 104.6.5 BUILDING PERMIT
 VALUATION: SUBMIT SIGNED CONTRACT TO
 VERIFY VALUE OF SIGN INCLUDING MFGR,
 LABOR & MATERIALS, OVERHEAD & PROFIT.
  
 2. NO ELECTRICIAN IS SIGNED ON TO THE
 PERMIT.IF THIS IS A LIGHTED SIGN AN
 ELECTRICIAN MUST SUBMIT ELECTRICAL PLANS
 & PAY SEPARATE PERMIT FEES.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-01-30 Cont ID  
Sent By dpalmer Date 2006-01-30 Time 20:33 Rev Time 0.00
Received By dpalmer Date 2006-01-30 Time 20:18 Sent To B
Notes
2006-01-30 00:00:00STAMPED ELECTRICAL DETAIL ONLY.
  
 CONTRACTOR DID NOT MAKE SETS OF PLANS
 REMOVING OLD SHEETS ETC.
 PACKAGE RE-SUBMITTED WITHOUT OBTAINING
 PLANS WHICH WERE SENT BY OVERNIGHT
 EXPRESS MAIL. THESE OVERNIGHTED PLANS
 WERE PLACED IN PACKAGE.
 SEESURVEY'S ETC.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2005-12-07 Cont ID  
Sent By dpalmer Date 2005-12-07 Time 18:38 Rev Time 0.50
Received By dpalmer Date 2005-12-07 Time 18:32 Sent To  
Notes
2005-12-07 00:00:00**** UNSAT 4TH REVIEW ****
  
 PLEASE SEE COMMENTS FROM ALL OTHER
 PREVIOUS REVIEWS.
  
  
 1)NOTE: PLEASE SEE ALL PLANS MUST
 CONTAIN THE "PRINTED NAME AND THE
 SIGNATURE OF THE PERSON RESPONSIBLE FOR
 PLANS/DESIGN".
 PLEASE SEE ELECTRICAL PLANS , SHEETS
 ATTACHMENTS.
 PLEASE SEE FLORIDA BUILDING CODE
 ADMINISTRATIVE SECTION
 104.2.1
  
 2)NOTE: PLEASE SEE FLORIDA STATUES
 471.023 AND FLORIDA AMINISTRATIVE CODE
 61G15-23.002.
 THE FS REQUIRES THE CERTIFICATE OF
 AUTHORIZATION NUMBER FOR THE ENGINEERING
 FIRM AS LISTED ON TITLE BLOCK.THE FAC
 REQUIRES THAT TO BE PRINTED ON THE TITLE
 BLOCK ALONG WITH OTHER INFORMATION AS
 MENTIONED.
 PLEASE SEE A COPY OF A PRINT OUT FROM
 THE STATE DBPR WEBSITE INDICATES THE
 ENGINEERINGFIRM HAS A CA #, HOWEVER
 THIS IS STILL NOT PRINTED ON THE TITLE
 BLOCKS OF SAID PLANS WHICH ARE SIGNED,
 DATED AND SEALED BY SAID ENGINEER AND
 FIRM.
  
 ** CONTRACTOR**
  
 3)NOTE: PLEASE SEE THE VALUATION
 ADJUSTMENT WAS MADE BY THE BUILDING
 REVIEWER AND FEES ARE OWED.
  
 4)NOTE: PLEASE SEE A NOTICE OF
 COMMENCMENT WAS SUBMITTED, HOWEVER THIS
 WAS NOT RECORDED AS REQUIRED UNDER
 FS713.13
  
 *** PLEASE SEE COMMENTS #1 AND #2, THIS
 HAS BEEN REQUESTED ON OTHER REVIEWS AND
 STILL ALL COMMENTS HAVE NOT BEEN
 ADDRESSED.
 PLEASE SEE FS 553.80(2)(B), IF PLANS
 COME BACK WITH OUT ANY OF THOSE TWO
 COMMENTS BEING ADDRESSED, A 4X FEE MAY
 BE ACESSED AND ALL PLANS MAY BE TURNED
 INTO THE STATE ENGINEERING BOARD AND
 CONTRACTORS LICENSING BOARD FOR REVIEW.
  
 PLEASE ADDRESS COMMENTS COMPLETELY AND
 ONCE AGAIN, IF THERE ARE ANY QUESTIONS,
 PLEASE CALL THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-09-20 Cont ID  
Sent By dpalmer Date 2005-09-20 Time 09:22 Rev Time 0.25
Received By dpalmer Date 2005-09-20 Time 09:22 Sent To B
Notes
2005-09-20 00:00:00******* UNSAT 3RD REVIEW ************
  
 PLEASE SEE SAME NOTES FROM PREVIOUS
 REVIEW.
  
 PLEASE SEE NO CHANGES WERE MADE TO
 VALUATION, PLANS, TITLE BLOCKS ETC.
 PLEASE SEE COPY OF PREVIOUS NOTES
 ATTACHED.
  
 PLEASE ALSO SEE COPY OF FS 553.80(2)(B)
 WITH RESPECT TO DESIGN PROFESSIONAL AND
 REPEAT COMMENTS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-06-28 Cont ID  
Sent By dpalmer Date 2005-06-28 Time 07:25 Rev Time 0.25
Received By dpalmer Date 2005-06-28 Time 07:25 Sent To B
Notes
2005-06-28 00:00:00******** UNSAT 2ND REVIEW *********
  
 PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW STILL NEED TO BE ADDRESSED.
  
 1)NOTE: PLEASE SEE ALL PLANS MUST
 CONTAIN THE PRINTED NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR PLANS AND
 /OR DESIGN. FBC 104.2.1
  
 2)NOTE: PLEASE NOW SEE PLANS WHICH ARE
 NOW SIGNED AND SEALED BY AN ENGINEER,
 MUST CONTAIN TITLE BLOCKS WITH ALL
 INFORMATION ON SAID TITLE BLOCK AS
 SET-FORTH UNDE FAC 61G15-23.002 FOR
 ENG'S. FS 471.023
 THIS COMMENT IS FOR ALL SHEETS SIGNED
 AND SEALED WHEATHER OR NOT COMMENT IS
 MADE BY OTHER REVIEWER(S).
  
 3)NOTE: PLEASE SEE VALUATION HAS NOT
 BEEN INCREASED AS OF RESUBMITTAL. IF THE
 APPROPRIATE VALUEADJUSTED, AND
 ADJUSTMENT WILL BE MADE BY THIS OFFICE
 BASED ON CODE/MARSHALL'S SWIFT TABLES.
 PLEASE ALSO SEE BLDG REVIEW COMMENTS FOR
 THIS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-06-08 Cont ID  
Sent By dpalmer Date 2005-06-08 Time 11:36 Rev Time 0.15
Received By dpalmer Date 2005-06-08 Time 11:36 Sent To B
Notes
2005-06-08 00:00:00**********UNSAT **********
  
 1)NOTE: PLEASE SUBMIT MORE ELECTRICAL
 INFORMATION ON HOW SIGN IS BEING LIT.
 PLEASE INCLUDE TRANSFORMER/BALLAST ETC.
  
 2)NOTE: PLANS MUST CONTAIN THE PRINTED
 NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR PLANS/DESIGN.
  
 3)NOTE: PLEASE SEE VALUATION IS REFLECT
 ALL LABOR AND MATERIALS EVEN IF ANY PART
 IS OWNER SUPPLIED.
 FBC 104.6.5
 SEE BLDG REVIEW COMMENTS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-23 Cont ID  
Sent By adarroug Date 2006-01-23 Time 09:57 Rev Time 0.00
Received By adarroug Date 2006-01-23 Time 09:57 Sent To E
Notes
2006-01-23 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-11-30 Cont ID  
Sent By adarroug Date 2005-11-30 Time 18:52 Rev Time 0.00
Received By adarroug Date 2005-11-30 Time 18:52 Sent To  
Notes
2005-11-30 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-27 Cont ID  
Sent By adarroug Date 2005-06-27 Time 10:48 Rev Time 0.00
Received By adarroug Date 2005-06-27 Time 10:48 Sent To E
Notes
2005-06-27 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-06 Cont ID  
Sent By mjacobs Date 2005-06-06 Time 16:32 Rev Time 0.00
Received By mjacobs Date 2005-06-06 Time 16:32 Sent To E
Notes
2005-06-06 00:00:00TO 'E' BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-31 Cont ID  
Sent By adarroug Date 2005-05-31 Time 10:21 Rev Time 0.00
Received By adarroug Date 2005-05-31 Time 10:21 Sent To Z
Notes
2005-05-31 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2005-06-03 Time   Rev Time  
Received By   Date 2005-06-03 Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved