| Plan Review Stops For Permit 05051845 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-24 |
Time |
06:42 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2005-08-24 |
Time |
06:42 |
Sent To |
PC |
|
| Notes |
| 2005-08-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05051845 | | | ADD: 7322 HORIZON DR | | | CONT: WEATHERGUARD BUILDING PRO | | | TEL: (561)790-5799 | | | FL BLDG CODE= 2001 FLORIDA BUILDING | | | CODE*= WEST PALM BEACH AMENDMENTS | | | | | | FENCE & GATES REVIEW | | | BUILDING : PROVISO | | | | | | SWIMMING POOL ACCESS GATES: | | | 424.2.17.1.8 ACCESS GATES, WHEN | | | PROVIDED, SHALL BE SELF-CLOSING AND | | | SHALL COMPLY WITH THE REQUIREMENTS OF | | | ?424.2.17.1.1 THROUGH 424.2.17.1.7 AND | | | SHALL BE EQUIPPED WITH A SELF-LATCHING | | | LOCKING DEVICE LOCATED ON THE POOL SIDE | | | OF THE GATE.WHERE THE DEVICE RELEASE | | | IS LOCATED NO LESS THAN 54 INCHES FROM | | | THE BOTTOM OF THE GATE, THE DEVICE | | | RELEASE MECHANISM MAY BE LOCATED ON | | | EITHER SIDE OF THE GATE AND SO PLACED | | | THAT IT CANNOT BE REACHED BY A YOUNG | | | CHILD OVER THE TOP OR THROUGH ANY | | | OPENING OR GAPS FROM THE OUTSIDE.GATES | | | THAT PROVIDE ACCESS TO THE SWIMMING POOL | | | MUST OPEN OUTWARD AWAY FROM THE POOL. | | | THE GATES AND BARRIER SHALL HAVE NO | | | OPENING GREATER THAN1/2 INCH WITHIN 18 | | | INCHES OF THE RELEASE MECHANISM. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-06 |
Time |
07:52 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2005-08-06 |
Time |
07:52 |
Sent To |
PC |
|
| Notes |
| 2005-08-06 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05051845 | | | ADD: 7322 HORIZONS | | | CONT: WEATHER GUARD BUILDING PRO. | | | | | | TEL: (561)790-5799 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1 )SHEET BY WEATHERGUARDBUILDING | | | PRODUCTS,FBC 104.2.1ALL INFORMATION, | | | DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME | | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN.PLEASE COMPLY. | | | | | | 2) ENGINEERING SHEET:FRANK BENNARDO | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
11:35 |
Sent To |
B |
|
| Notes |
| 2005-08-18 00:00:00 | TO "JWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-26 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-26 |
Time |
13:23 |
Sent To |
B |
|
| Notes |
| 2005-07-26 00:00:00 | TO "MISC" BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-14 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-14 |
Time |
14:50 |
Sent To |
Z |
|
| Notes |
| 2005-07-14 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-31 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-31 |
Time |
11:02 |
Sent To |
Z |
|
| Notes |
| 2005-05-31 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-25 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-25 |
Time |
10:56 |
Sent To |
I |
|
| Notes |
| 2005-07-25 00:00:00 | NOTE: COLUNMS/GATE/FENCE CAN ONLY BE MAX | | | OF 4FT HIGH WITHIN THE FIRST 25FT FRONT | | | SETBACK. BEYOND THE 25FT FRONT SETBACK | | | COLUMNS/GATE/FENCE CAN BE A MAX. OF 6FT | | | HIGH. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-08 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-08 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2005-06-08 00:00:00 | DENIED, | | | 1. NEED TO PROVIDE A COLUMN DETAIL | | | SHOWING THE HEIGHT OF THE COLUMNS TO | | | SCALE. | | | 2. MAX. HEIGHT ALLOWED WITHIN THE FIRST | | | 25FT FRONT SETBACK IS 4FT AND BEYOND THE | | | 25FT FRONT SETBACK 6FT. | | | 3. NEED TO HIGHTLIGHT THE FRONT SETBACK | | | ON THE 2 COPY OF SURVEY. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|