Plan Review Details - Permit 05051833
Plan Review Stops For Permit 05051833
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-14 Cont ID  
Sent By jwitmer Date 2005-07-14 Time 15:15 Rev Time 3.33
Received By jwitmer Date 2005-07-14 Time 15:15 Sent To PC
Notes
2005-07-14 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05051833
 ADD: 2211 N FLAGLER DR
 CONT: PLAN REVIEW/ LIFE SAFETY
 MERCO GROUP
 TEL: (561)289-0276
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) NOE SEET OF PLANS IS MISSING THE
 LS0.01 UNDER GROUND TUNNEL/ EXIT
 PASSAGE.
  
 2) THE SHEET LS0.01 SECTION OF THE EXIT
 PASSAGE INDICATES A HEIGHT OF 7'-0".SEE
 1003.2.5 HEADROOM. MEANS OF EGRESS SHALL
 BE DESIGNED AND MAINTAINED TO
 PROVIDE A MINIMUM HEADROOM OF 7 FT 6
 IN. (2.3 M) WITH PROJECTIONS FROM
 THE CEILING AT LEAST 6 FT 8 IN. (2 M)
 NOMINAL HEIGHT ABOVE THE FINISHED
 FLOOR.DOORWAYS IN A MEANS OF EGRESS
 SHALL PROVIDE A MINIMUM HEADROOM OF
 6 FT 8 IN. (2 M).STAIRS IN A MEANS
 OF EGRESS SHALL COMPLY WITH 1007.7.
  
 3) PLANS TO INDICATE COMPLIANCE WITH THE
 HEADROOM REQUIREMENTS ( PROJECTIONS) FOR
 LIGHTING, EMERGENCY LIGHTING, FIRE
 SPRINKLERS, EXIT SIGNAGE, ETC.
  
 4) SHEET LS0.01INDICATES A TUNNEL
 EFFECT, PROVIDE HOW STAIRWELL
 PRESSURIZATION WILL TAKE PLACE IN EACH
 SEGMENT?1005.6.9.1 STAIR
 PRESSURIZATION SYSTEMS SHALL BE
 INDEPENDENT OF OTHER BUILDING
 VENTILATION SYSTEMS.
  
 5) WILL THERE BE CO2 DETECTORS?
  
 6) PROVIDE INFORMATION ON HOW THE FIRE
 DEPARTMENT WILL GAIN ACCESS TO THE
 UNDERGROUND EXIT PASSAGEWAYS FROM THE
 STREET?
  
 7) PLANS DO NOT INDICATE THE RATING OF
 THE WALLS OR DOORS IN THE STAIRS AND
 EXIT PASSAGE WAY?
  
 8) SHEET LS0.05 IS MISSING DOORS FROM
 CONDO TO EXIT STAIRWAY:
 412.6.2 OPENINGS IN THE ELEVATOR LOBBY
 SHALL BE LIMITED TO THOSE
 REQUIRED FOR ACCESS TO THE ELEVATORS
 AND FOR EGRESS FROM THE BUILDING.
 ALL ROOMS AND ENCLOSURES SHALL HAVE AT
 LEAST ONE REQUIRED EXIT ACCESSIBLE
 WITHOUT TRAVEL THROUGH THE ELEVATOR
 LOBBY.OPENINGS MAY BE PROVIDED WITH
 HORIZONTAL SLIDING DOORS CONFORMING TO
 ?1012.4.EXIT STAIRWAYS, CHUTES,
 JANITOR CLOSETS, GUEST ROOMS, SERVICE
 ROOMS, ETC., SHALL NOT OPEN INTO THE
 ELEVATOR LOBBY.
  
 9) PLEASE PROVIDE WHAT LEVELS RE-ENTRY
 WILL BE ALLOWED? WILL RE-ENTRY BE
 ALLOWED FOR THE POOL LEVEL DECK?
 1012.1.11 EVERY DOOR IN A STAIR
 ENCLOSURE SERVING MORE THAN FOUR
 STORIES SHALL PERMIT RE-ENTRY FROM THE
 STAIR ENCLOSURE TO THE INTERIOR OF
 THE BUILDING, OR AN AUTOMATIC RELEASE
 SHALL BE PROVIDED TO UNLOCK ALL
 STAIR ENCLOSURE DOORS TO PERMIT
 RE-ENTRY.SUCH AUTOMATIC RELEASE SHALL
 BE
 ACTUATED WITH THE INITIATION OF THE
 BUILDING FIRE ALARM, FIRE DETECTION OR
 FIRE SPRINKLER SYSTEM.
  
 EXCEPTION: DOORS ON STAIR ENCLOSURES
 SHALL BE PERMITTED TO BE
 EQUIPPED WITH HARDWARE THAT PREVENTS
 RE-ENTRY INTO THE INTERIOR OF THE
 BUILDING, PROVIDED THAT THE
 FOLLOWING CONDITIONS ARE MET:
  
 1. THERE ARE AT LEAST TWO LEVELS
 WHERE IT IS POSSIBLE TO LEAVE THE
 STAIR ENCLOSURE; AND
  
 2. THERE ARE NOT MORE THAN FOUR
 STORIES INTERVENING BETWEEN STORIES
 WHERE IT IS POSSIBLE TO LEAVE THE
 STAIR ENCLOSURE; AND
  
 3. RE-ENTRY IS POSSIBLE ON THE TOP
 OR NEXT TO TOP STORY PERMITTING
 ACCESS TO ANOTHER EXIT; AND
  
 4. DOORS PERMITTING RE-ENTRY ARE
 IDENTIFIED AS SUCH ON THE STAIR SIDE
 OF THE DOOR; AND
  
 5. DOORS NOT PERMITTING RE-ENTRY
 SHALL BE PROVIDED WITH A SIGN ON THE
 STAIR SIDE INDICATING THE
 LOCATION OF THE NEAREST DOOR, IN EACH
 DIRECTION OF TRAVEL, PERMITTING
 RE-ENTRY OR EXIT.
  
 10) PLAZA DECK THERE WAS DISCUSSION AS
 TO HOW EXIT SIGNS WERE GOING TO BE
 PLACED AROUND THE PLAZA POOL DECK WITH
 THE CABANAS OBSSTRUCTING THE VIEW OF
 EXIT SIGNS, ONE ITEM THAT WAS NOT
 DISCUSSED WAS COMPLIANCE FOR THE BLIND,
 SEE 11-4.30.1-7.
  
 11) WITHOUT HAVING A COMPLETE SET OF
 PLANS INDICATING VARIOUS SITUATIONS
 OTHER AREAS OF CONCERN WILL BE :
 11-4.29.2 DETECTABLE WARNING ON WALKING
 SURFACES.
 11-4.29.5 DETECTABLE WARNINGS AT
 HAZARDOUS VEHICULAR AREAS.
 11-4.29.6 DETECTABLE WARNINGS AT
 REFLECTING POOLS.
 11-4.28.1-4 AUDIBLE AND VISUAL ALARMS.
  
 THIS IS A REVIEW OF ONLY LIFE SAFETY,
 OTHER ISSUES MAY ARISE WHEN A COMPLETE
 SET OF PLANS ARE PROVIDED, AND IN NO WAY
  
 CONSTITUTES A PERMIT WOULD BE ISSUED
 WHEN THESE COMMENTS ARE MET.
  
 THE OTHER ISSUE WILL BE WHEN THE
 BUILDING WILL BE BROUGHT IN UNDER A
 PERMIT APPLICATION. BETWEEN JULY 1/05 &
 SEPT.30/05 THE DESIGNER MAY DESIGN TO
 EITHER THE 2001 OR 2004 FLORIDA CODE,
 THE PLANS MUST INDICATE AS TO WHICH CODE
 THE BUILDING WAS DESIGNED. AFTER
 SEPT.30/05 THE 2004 FLORIDA CODE MUST BE
 THE DESIGN CRITERIA.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2005-07-14 Cont ID  
Sent By jwitmer Date 2005-07-14 Time 15:14 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2005-07-14 Cont ID  
Sent By jwitmer Date 2005-07-14 Time 15:14 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-07-14 Cont ID  
Sent By mwennerg Date 2005-07-14 Time 13:56 Rev Time 0.00
Received By mwennerg Date 2005-07-14 Time 13:56 Sent To  
Notes
2005-07-14 00:00:00******DENIED******
  
 PLAN REVIEW ONLY
  
 1) THE EXIT PASSAGEWAY ILLUSTRATES AN
 OVERALL HEIGHT OF 7'-0". PLEASE NOTE
 THAT NFPA 101, SECTION 7.1.5 REQUIRES A
 MINIMUM OF 90" WITH PROJECTIONS FROM THE
 CEILING NOT LESS THAN 80".
  
 2) SOME OF THE MIDDLE UNITS ONLY SHOW
 EXITING THROUGH THE ELEVATOR LOBBIES. NO
 EXIT CAN BE FOUND THAT LEADS DIRECTLY
 THE THE STAIRWELLS.
  
 3) PLEASE SHOW THE LOCATIONS OF ALL
 ILLUMINATED EXIT SIGNS AND EMERGENCY
 LIGHTING FACILITIES.
  
 4) PLEASE INDICATE IF ACCESS INTO THE
 EXIT PASSAGEWAY IS PROVIDED, AND HOW
 WILL THAT BE ACCOMPLISHED?
  
 5) PLEASE INDICATE IF THE TRAFFIC AREA
 ABOVE THE EXIT PASSAGEWAY WILL SUPPORT
 THE LARGEST FIRE DEPARTMENT VEHICLES.
  
 6) KNOX BOXES WILL BE REQUIRED.
  
 7) 2A-10B,C RATED FIRE EXTINGUISHERS ARE
 REQUIRED TO BE MOUNTED NOT TO EXCEED 75'
 TRAVEL DISTANCE.
  
 8) REENTRY INTO THE STAIRWELLS WILL BE
 REQUIRED AT THE LEVEL OF THE POOL DECK
 AREA.
  
 9) MORE DETAILS ARE NEEDED FOR THE DOORS
 IN REGARDS TO THE EXIT PASSAGEWAY.
  
 10) WHAT SAFEGUARDS WILL BE UTILIZED TO
 PREVENT THE ACCUMULATION OF CO?
  
  
 MIKE WENNERGREN, CAPTAIN
 WPBFR(561) 805-6722 OR 835-2951

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2005-06-01 Time 13:13 Sent To  
Notes
2005-07-12 00:00:00TO "F" DESK
2005-06-01 00:00:00IN INCOMING AWAITING SPACE ON "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-07-14 Cont ID  
Sent By jwitmer Date 2005-07-14 Time 15:14 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-07-14 Cont ID  
Sent By jwitmer Date 2005-07-14 Time 15:14 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2005-07-14 Cont ID  
Sent By jwitmer Date 2005-07-14 Time 15:14 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***