| Plan Review Stops For Permit 05051680 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-12-13 |
Time |
08:47 |
Rev Time |
0.25 |
| Received By |
mjacobs |
Date |
2005-12-13 |
Time |
08:47 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-08-18 |
Time |
14:43 |
Rev Time |
1.50 |
| Received By |
mjacobs |
Date |
2005-08-18 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-24 |
Time |
15:07 |
Rev Time |
2.50 |
| Received By |
mjacobs |
Date |
2005-06-24 |
Time |
11:40 |
Sent To |
PC |
|
| Notes |
| 2005-06-24 00:00:00 | 1) 713.13 F.S.A NOTICE OF | | | COMMENCEMENT SHALL BE RECORDED AT PALM | | | BEACH COUNTY COURTHOUSE AND A COPY | | | SUBMITTED TO THIS OFFICE BEFORE A PERMIT | | | CAN BE ISSUED. BLANK FORMS ARE AVAILABLE | | | FROM THIS OFFICE. NOTE: THE NOTICE OF | | | COMMENCEMENT MUST BE RE-RECORDED IF THE | | | DESCRIBED IMPROVEMENT OR CONSTRUCTION IS | | | NOT COMMENCED WITHIN 90 DAYS OF | | | RECORDING. | | | | | | 2) THE TYPE OF INSULATION MENTIONED FOR | | | THE CEILING IS R-30 ON THE FLOOR PLAN | | | AND ON THE INTERIOR WALL DETAIL IT SHOWS | | | R-19. CLARIFY. | | | | | | 3) PROVIDE A DETAIL DRAWING FOR THE | | | FRAMING AROUND THE DOORS AND | | | WINDOWS.ALSO WILL THE NEW WALLS BE OF | | | WOOD OR CONCRETE BLOCK ? | | | | | | 4) FBC 2309.6ACCESS TO ATTIC SPACE | | | EACH ATTIC SPACE WITH A CLEAR HEIGHT OF | | | 24" OR GREATER SHALL BE PROVIDED WITH AN | | | INTERIOR ATTIC ACCESS OPENING NOT LESS | | | THAN 20"X 36". SHOW YOUR ATTIC ACCESS. | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-20 |
Time |
16:23 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-20 |
Time |
16:37 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-17 |
Time |
07:53 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-17 |
Time |
07:35 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-10 |
Time |
14:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-09 |
Time |
14:04 |
Sent To |
P |
|
| Notes |
| 2005-06-10 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT A RISER DIAGRAM | | | INDICATING CONDUIT, CONDUCTOR SIZES AND | | | CONFIGURATION. ALSO GROUNDING AND | | | BONDING PER 250.50. | | | | | | 2} THE KITCHEN RECEPTACLES MUST COMPLY | | | WITH 210.52(C) SPACING AND | | | 210.8(A)(6),GFI. | | | | | | 3} A RECEPTACLE MUST BE ADDED FOR THE | | | A/C EQUIPMENT PER 210.63, ALSO | | | 210.52(E). | | | | | | 4} THE SPRINKLER PUMP IS NOT LISTED IN | | | THE LOAD CALCULATION. ADD SAME AND | | | RECALCULATE. THE 150 AMP SERVICE NEEDS | | | TO BE INCREASED. | | | | | | 5} A TANKLESS WATER HEATER IS SHOWN ON | | | THE PLAN, BUT THE CALCULATION IS SHOWN | | | AS 5KW. PLEASE CHECK THE NAMEPLATE | | | RATING AND SUBMIT SPECIFICATIONS FOR | | | SAME. | | | | | | 6} THE DISPOSAL IS NOT LISTED IN THE | | | CALCULATION. | | | | | | 7} 210.70(A)(2)(B), A LIGHT AND SWITCH | | | ARE REQUIRED AT THE EXTERIOR DOORS. | | | | | | 8} THE ENGINEERING TITLE BLOCK MUST | | | CONTAIN THE CETIFICATE OF AUTHORIZATION | | | (FIRM) LICENSE NUMBER PER 61G15-23.002. | | | FAC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-16 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-16 |
Time |
09:25 |
Sent To |
E |
|
| Notes |
| 2006-10-16 09:25:37 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
14:19 |
Sent To |
B |
|
| Notes |
| 2005-12-12 00:00:00 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-16 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-16 |
Time |
13:19 |
Sent To |
E |
|
| Notes |
| 2005-08-16 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-05 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-05 |
Time |
15:03 |
Sent To |
Z |
|
| Notes |
| 2005-08-05 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-09 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-09 |
Time |
06:59 |
Sent To |
E |
|
| Notes |
| 2005-06-09 00:00:00 | TO ELEC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-24 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-05-24 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2005-05-24 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-18 |
Time |
15:49 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2005-08-18 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-18 |
Time |
08:18 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-08-18 |
Time |
08:18 |
Sent To |
B |
|
| Notes |
| 2005-08-18 00:00:00 | MECH. PLAN REV. RRESUB 8/4/05: | | | | | | 1. HVAC PLAN NOT COMPLETE. | | | | | | NO EQUIPMENT INFORMATION. | | | | | | INCOMPLET A/C PLAN. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-16 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-16 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2005-06-16 00:00:00 | NO PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-17 |
Time |
09:36 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-08-17 |
Time |
09:36 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-14 |
Time |
12:41 |
Rev Time |
0.65 |
| Received By |
kstevens |
Date |
2005-06-14 |
Time |
12:41 |
Sent To |
M |
|
| Notes |
| 2005-06-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT A-1 PLUMBING RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. CORRECT THE | | | FOLLOWING: | | | A. KITCHEN SINK IS NOT VENTED. SECTION | | | 901.2.1. | | | B. NO DRY HORIZONTAL VENTS. SECTIONS | | | 905.3 & 905.4. | | | C. WASH MACHINE IS NOT VENTED, & SHALL | | | HAVE A TRAP,A STANDPIPE, AND A | | | CLEANOUT 4' ABOVE THE FLOOR. SECTIONS | | | 708.10, 901.2.1 & 1002.1. | | | D. THE SHOWER, WATER CLOSET, AND LAV | | | ARE NOT VENTED. SECTION 909.1 | | | 2. SEE RED LINE EXAMPLES TO BE CODE | | | COMPLIANT ON ONE SET OF DRAWINGS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-08-12 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-08-12 |
Time |
15:52 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-08 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-08 |
Time |
09:29 |
Sent To |
I |
|
| Notes |
| 2005-06-08 00:00:00 | DENIED, | | | 1. NEED TO PROVIDE TWO COPY OF SURVEY | | | SHOWING THE LOCATION OF THE WORK WITH | | | SETBACKS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|