Plan Review Details - Permit 05051680
Plan Review Stops For Permit 05051680
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-12-13 Cont ID  
Sent By mjacobs Date 2005-12-13 Time 08:47 Rev Time 0.25
Received By mjacobs Date 2005-12-13 Time 08:47 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-08-18 Cont ID  
Sent By mjacobs Date 2005-08-18 Time 14:43 Rev Time 1.50
Received By mjacobs Date 2005-08-18 Time 13:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-24 Cont ID  
Sent By mjacobs Date 2005-06-24 Time 15:07 Rev Time 2.50
Received By mjacobs Date 2005-06-24 Time 11:40 Sent To PC
Notes
2005-06-24 00:00:001) 713.13 F.S.A NOTICE OF
 COMMENCEMENT SHALL BE RECORDED AT PALM
 BEACH COUNTY COURTHOUSE AND A COPY
 SUBMITTED TO THIS OFFICE BEFORE A PERMIT
 CAN BE ISSUED. BLANK FORMS ARE AVAILABLE
 FROM THIS OFFICE. NOTE: THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED IF THE
 DESCRIBED IMPROVEMENT OR CONSTRUCTION IS
 NOT COMMENCED WITHIN 90 DAYS OF
 RECORDING.
  
 2) THE TYPE OF INSULATION MENTIONED FOR
 THE CEILING IS R-30 ON THE FLOOR PLAN
 AND ON THE INTERIOR WALL DETAIL IT SHOWS
 R-19. CLARIFY.
  
 3) PROVIDE A DETAIL DRAWING FOR THE
 FRAMING AROUND THE DOORS AND
 WINDOWS.ALSO WILL THE NEW WALLS BE OF
 WOOD OR CONCRETE BLOCK ?
  
 4) FBC 2309.6ACCESS TO ATTIC SPACE
 EACH ATTIC SPACE WITH A CLEAR HEIGHT OF
 24" OR GREATER SHALL BE PROVIDED WITH AN
 INTERIOR ATTIC ACCESS OPENING NOT LESS
 THAN 20"X 36". SHOW YOUR ATTIC ACCESS.
  
 BUILDING PLAN REVIEW
 MYRON JACOBS
 TEL: (561)805-6726
 FAX: (561)659-8026
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-10-31 Cont ID  
Sent By btrobaug Date 2006-10-20 Time 16:23 Rev Time 0.50
Received By btrobaug Date 2006-10-20 Time 16:37 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-08-17 Cont ID  
Sent By btrobaug Date 2005-08-17 Time 07:53 Rev Time 0.50
Received By btrobaug Date 2005-08-17 Time 07:35 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-06-10 Cont ID  
Sent By btrobaug Date 2005-06-10 Time 14:32 Rev Time 0.50
Received By btrobaug Date 2005-06-09 Time 14:04 Sent To P
Notes
2005-06-10 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE SUBMIT A RISER DIAGRAM
 INDICATING CONDUIT, CONDUCTOR SIZES AND
 CONFIGURATION. ALSO GROUNDING AND
 BONDING PER 250.50.
  
 2} THE KITCHEN RECEPTACLES MUST COMPLY
 WITH 210.52(C) SPACING AND
 210.8(A)(6),GFI.
  
 3} A RECEPTACLE MUST BE ADDED FOR THE
 A/C EQUIPMENT PER 210.63, ALSO
 210.52(E).
  
 4} THE SPRINKLER PUMP IS NOT LISTED IN
 THE LOAD CALCULATION. ADD SAME AND
 RECALCULATE. THE 150 AMP SERVICE NEEDS
 TO BE INCREASED.
  
 5} A TANKLESS WATER HEATER IS SHOWN ON
 THE PLAN, BUT THE CALCULATION IS SHOWN
 AS 5KW. PLEASE CHECK THE NAMEPLATE
 RATING AND SUBMIT SPECIFICATIONS FOR
 SAME.
  
 6} THE DISPOSAL IS NOT LISTED IN THE
 CALCULATION.
  
 7} 210.70(A)(2)(B), A LIGHT AND SWITCH
 ARE REQUIRED AT THE EXTERIOR DOORS.
  
 8} THE ENGINEERING TITLE BLOCK MUST
 CONTAIN THE CETIFICATE OF AUTHORIZATION
 (FIRM) LICENSE NUMBER PER 61G15-23.002.
 FAC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-10-16 Cont ID  
Sent By adarroug Date 2006-10-16 Time 09:25 Rev Time 0.00
Received By adarroug Date 2006-10-16 Time 09:25 Sent To E
Notes
2006-10-16 09:25:37TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-12-12 Cont ID  
Sent By adarroug Date 2005-12-12 Time 14:19 Rev Time 0.00
Received By adarroug Date 2005-12-12 Time 14:19 Sent To B
Notes
2005-12-12 00:00:00TO "MJACOBS" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-16 Cont ID  
Sent By adarroug Date 2005-08-16 Time 13:19 Rev Time 0.00
Received By adarroug Date 2005-08-16 Time 13:19 Sent To E
Notes
2005-08-16 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-05 Cont ID  
Sent By adarroug Date 2005-08-05 Time 15:03 Rev Time 0.00
Received By adarroug Date 2005-08-05 Time 15:03 Sent To Z
Notes
2005-08-05 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-09 Cont ID  
Sent By shill Date 2005-06-09 Time 06:59 Rev Time 0.00
Received By shill Date 2005-06-09 Time 06:59 Sent To E
Notes
2005-06-09 00:00:00TO ELEC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-24 Cont ID  
Sent By mjacobs Date 2005-06-24 Time 15:55 Rev Time 0.00
Received By mjacobs Date 2005-05-24 Time 17:52 Sent To  
Notes
2005-05-24 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-08-18 Cont ID  
Sent By pkrauss Date 2005-08-18 Time 15:49 Rev Time 0.20
Received By pkrauss Date 2005-08-18 Time 15:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-08-18 Cont ID  
Sent By prafter Date 2005-08-18 Time 08:18 Rev Time 0.50
Received By prafter Date 2005-08-18 Time 08:18 Sent To B
Notes
2005-08-18 00:00:00MECH. PLAN REV. RRESUB 8/4/05:
  
 1. HVAC PLAN NOT COMPLETE.
  
 NO EQUIPMENT INFORMATION.
  
 INCOMPLET A/C PLAN.
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-06-16 Cont ID  
Sent By hmoser Date 2005-06-16 Time 14:58 Rev Time 0.00
Received By hmoser Date 2005-06-16 Time 14:50 Sent To  
Notes
2005-06-16 00:00:00NO PLANS

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-17 Cont ID  
Sent By jleech Date 2005-08-17 Time 09:36 Rev Time 0.33
Received By jleech Date 2005-08-17 Time 09:36 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-06-14 Cont ID  
Sent By kstevens Date 2005-06-14 Time 12:41 Rev Time 0.65
Received By kstevens Date 2005-06-14 Time 12:41 Sent To M
Notes
2005-06-14 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1. SHT A-1 PLUMBING RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS. CORRECT THE
 FOLLOWING:
 A. KITCHEN SINK IS NOT VENTED. SECTION
 901.2.1.
 B. NO DRY HORIZONTAL VENTS. SECTIONS
 905.3 & 905.4.
 C. WASH MACHINE IS NOT VENTED, & SHALL
 HAVE A TRAP,A STANDPIPE, AND A
 CLEANOUT 4' ABOVE THE FLOOR. SECTIONS
 708.10, 901.2.1 & 1002.1.
 D. THE SHOWER, WATER CLOSET, AND LAV
 ARE NOT VENTED. SECTION 909.1
 2. SEE RED LINE EXAMPLES TO BE CODE
 COMPLIANT ON ONE SET OF DRAWINGS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2005-08-18 Cont ID  
Sent By mmclean Date 2005-08-12 Time 15:52 Rev Time 0.00
Received By mmclean Date 2005-08-12 Time 15:52 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-06-08 Cont ID  
Sent By mmclean Date 2005-06-08 Time 09:29 Rev Time 0.00
Received By mmclean Date 2005-06-08 Time 09:29 Sent To I
Notes
2005-06-08 00:00:00DENIED,
 1. NEED TO PROVIDE TWO COPY OF SURVEY
 SHOWING THE LOCATION OF THE WORK WITH
 SETBACKS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved