Plan Review Details - Permit 05051633
Plan Review Stops For Permit 05051633
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-07-19 Cont ID  
Sent By alange Date 2005-07-19 Time 09:04 Rev Time 1.00
Received By alange Date 2005-07-19 Time 07:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-27 Cont ID  
Sent By alange Date 2005-06-27 Time 10:57 Rev Time 1.00
Received By alange Date 2005-06-03 Time 15:29 Sent To  
Notes
2005-06-27 00:00:00DENIED
  
 1.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SHOW METHOD OF TIE-IN FROM EXISTING
 SLAB TO NEW.
  
 4.SUBMIT TWO COPIES OF MANUAL "J"
 ENERGY CALCS.
  
 5.SHOW ROOF SHEATHING NAILING SCHEDULE
 COMPLYING WITH FBC 2306.9 WPB
 AMMENDMENTS.
  
 6.THERMA-TRU EXTERIOR DOOR IS NOT
 IMPACT RATED.SUBMIT PRODUCT APPROVALS
 FOR AN IMPACT RATED DOOR OR IMPACT
 PROTECTION WILL BE REQUIRED WITH PRODUCT
 APPROVALS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
2005-05-26 00:00:00TO "Z" BOX

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2005-06-10 Cont ID  
Sent By btrobaug Date 2005-06-10 Time 15:26 Rev Time 0.33
Received By btrobaug Date 2005-06-10 Time 15:17 Sent To P
Notes
2005-06-10 00:00:00 
 AN ELECTRICAL PERMIT IS REQUIRED FOR THE
  
 SCOPE OF WORK DESCRIBED.
  
 PLEASE SUBMIT PLANS PER FBC 104.2.1,
 WITH INFORMATION REQUIRED BY THE 2002
 NEC*.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-18 Cont ID  
Sent By adarroug Date 2005-07-18 Time 15:57 Rev Time 0.00
Received By adarroug Date 2005-07-18 Time 15:57 Sent To B
Notes
2005-07-18 00:00:00TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-27 Cont ID  
Sent By alange Date 2005-06-27 Time 10:58 Rev Time 0.00
Received By alange Date 2005-06-06 Time 13:44 Sent To  
Notes
2005-06-06 00:00:00TO 'E' BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-06 Cont ID  
Sent By mjacobs Date 2005-06-06 Time 13:43 Rev Time 0.00
Received By mjacobs Date 2005-05-26 Time 14:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-06-16 Cont ID  
Sent By hmoser Date 2005-06-16 Time 15:02 Rev Time 0.00
Received By hmoser Date 2005-06-16 Time 15:02 Sent To B
Notes
2005-06-16 00:00:00PLEASE HAVE AIRCONDITIONING CONTRACTOR
 SUBMIT PLANS,ENERGY CALCULATIONS AND
 MANUAL (J) AT TIME OF APPLICATION
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-06-14 Cont ID  
Sent By kstevens Date 2005-06-14 Time 09:50 Rev Time 0.30
Received By kstevens Date 2005-06-14 Time 09:50 Sent To M
Notes
2005-06-14 00:00:00NO SANT. RISER DIAGRAM SUBMITTED

Review Stop Z ZONING
Rev No 1 Status P Date 2005-06-03 Cont ID  
Sent By sgraham Date 2005-06-03 Time 15:30 Rev Time 0.00
Received By sgraham Date 2005-06-03 Time 15:30 Sent To  
Notes
***NONE***