Plan Review Details - Permit 05051568
| Plan Review Stops For Permit 05051568 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-07-07 |
Time |
14:42 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-07-07 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-11 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-06-11 |
Time |
11:59 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-28 |
Time |
07:48 |
Rev Time |
0.10 |
| Received By |
dpalmer |
Date |
2005-06-28 |
Time |
07:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-08 |
Time |
12:51 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-08 |
Time |
12:51 |
Sent To |
P |
|
| Notes |
| 2005-06-08 00:00:00 | *********UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE WIRING DIAGRAM | | | SUBMITTED SHOWS A RISER DIAGRAM FOR A | | | NEW SERVICE. IF A NEW SERVICEIS GOING TO | | | BE INSTALLED, THIS MUST BE UNDER A | | | SEPARATE PERMIT. | | | PLEASE ONLY SUBMIT THE ELECTRICAL WIRING | | | DIAGRAM RELATIVE TO POOL. | | | IF NEW POOL PANEL IS BEING INSTALLED, | | | THEN PLEASE INCLUDE OCP FROM EXISTING | | | PANEL(IF EXSITNG) SIZE OF SERVICE ETC. | | | PLEASE CLARIFY TYPE OF CONDUIT TO SUB | | | PANEL. | | | PLEASE SEE TYOE OF CONDUIT APPROVED FOR | | | USE AND INSTALLATIONS. ENMT? | | | | | | 2)NOTE: PLEASE SEE THE NUMBER OS | | | CONDUCTORS FROM MAIN PANEL TO SUB PANEL. | | | | | | THIS SEEMS TO BE MISSING EITHER THE | | | NUETRAL OER EQUIPMENT GROUNDING?? | | | 250.110,250.24, ETC. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-23 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-23 |
Time |
11:28 |
Sent To |
E |
|
| Notes |
| 2005-06-23 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-06 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-06 |
Time |
16:39 |
Sent To |
E |
|
| Notes |
| 2005-06-06 00:00:00 | TO 'E' BOX. POOL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
19:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
19:09 |
Sent To |
Z |
|
| Notes |
| 2005-05-24 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-11 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-06-11 |
Time |
11:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-06-03 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2005-06-03 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
|