| Plan Review Stops For Permit 05051512 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-25 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-07-25 |
Time |
09:21 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-07-25 |
Time |
09:21 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-07-19 |
Time |
07:52 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-07-19 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2005-07-19 00:00:00 | | | | BUILDING PLAN REVIEW: FAILED | | | | | | 1. SEE OTHER PLAN REVIEWERS' NOTES | | | REGARDING THE REQUIRED PRINTED NAME & | | | ORIGINAL SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DRAWING OF THE PLAN | | | THAT WAS SUBMITTED FOR PERMIT. IT | | | SHOWS THE FOLLOWING: | | | | | | 1. BUILDING IS APPROX. 19' X 35'. | | | 2. THERE IS A WALL A/C UNIT MOUNTED AT | | | THE REAR OF THE BUILDING BESIDE THE REAR | | | OUTSWING ENTRY DOOR. | | | 3. THERE IS A WALL UNIT A/C UNIT MOUNTED | | | AT THE FRONT WALL NEXT TO THE PROPOSED | | | STOREFRONT WINDOWS TO BE INSTALLED. | | | 4. THERE IS AN EXTERIOR OUTSWING DOOR IN | | | THE FRONT OF THE BUILIDNG. | | | 5. THE DRAWING ALSO SHOWS 7 CEILING | | | LIGHTS ( I SUPPOSE THEY ARE FLORESCENT) | | | MOUNTHED EVENLY SPACED ON THE CEILING OF | | | THE BUILDING. | | | 6. THERE IS A BATHROOM AT THE REAR OF | | | THE BUILDING TO THE RIGHT OF THE REAR | | | EXIT DOOR WITH AN OUTSWING DOOR.THE | | | FIXTURES INCLUDE A SINK & WATER CLOSET. | | | 7. THE OUTSIDE OF THE WALL OF THE BATH | | | HAS AN ELECTRICAL PANEL MOUNTED. | | | 8. THERE ARE 2 EMERGENCY LIGHTS | | | INSTALLED (ONE AT FRONT & ONE AT REAR OF | | | THE INTERIOR OF THE BUILDING.) | | | | | | REQUIREMENTS OF CONTRACTOR TO HAVE A | | | PASSED BUILDING PLAN REVIEW: | | | | | | I DREW A BOX ON THE PLAN.IT IS CALLED | | | A TITLE BOX. IN THE BOX PRINT THE NAME | | | OF THE PERSON WHO DREW THE PLAN.ON A | | | LINE ABOVE THE PRINTED NAME HAVE THE | | | PERSON SIGN THE FORM.AND DATE IT ON | | | THE DATE LINE. | | | | | | THIS A VERY SIMPLE PROCEDURE AND I KNOW | | | YOU PROBABLY FEEL WE ARE BEING REALLY | | | "NIT PICKEY" BUT IT IS THE "CODE"WPB | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | 2001: ADMINISTRATION CHAPTER 1: SEC. | | | 104.2.1 REQUIREMENTS. THE LAST LINE IN | | | THE CODE SECTION LISTED ABOVE READS "ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | PH: 805-6713 | | | EMAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-06-08 |
Time |
14:58 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-06-08 |
Time |
14:58 |
Sent To |
E |
|
| Notes |
| 2005-06-08 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | | | | 1. SUBMIT DRAWINGS OF THE STOREFRONT | | | WINDOWS. MUST COMPLY WITH THE WIND | | | DESIGN FOR PBC.IS THERE A DOOR BEING | | | INSTALLED? ONLY STOREFRONT WINDOW | | | PRODUCT APPROVALS SUBMITTED. SHOW SIZES. | | | | | | 2. SUBMIT AN INSTALLATION SCHEDULE FOR | | | THE STORM PANELS. HIGHLIGHT THE SECTIONS | | | OF THE DRAWINGS THAT PERTAIN TO THE | | | ASSEMBLY. MUST SHOW TYPE OF ANCHORS, | | | SPACING. | | | | | | 3. INTERIOR RENOVATIONS? REMOVING DROP | | | CEILING.DOES THIS INCLUDE ANY LIGHTING | | | AND A/C DUCT WORK? | | | | | | 4.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | I HAVE PRINTED OUT THE FLORIDA PRODUCT | | | APPROVALS FOR YOU FOR THE STORM PANELS & | | | STOREFRONTS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-29 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-29 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2005-09-29 00:00:00 | REV'S. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-03 |
Time |
15:07 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-08-03 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-27 |
Time |
08:16 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-06-27 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | ****** UNSAT ****** | | | | | | 1)NOTE: PLEASE SEE PLANS/DRAWINGS MUST | | | CONTAIN THE PRINTED NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR PLANS AND | | | DESIGN. FBC 104.2.1 | | | | | | 2)NOTE: PLEASE SEE 700.12E FOR | | | CIRCUITING OF EM/EXT LTS. | | | THESE MUST BE CIRCUITED TO LOCAL | | | LIGHTING BRANCH CIRCUITS. | | | | | | 3)NOTE: PLEASE SEE SHOW WINDOW RECEPT(S) | | | REQUIRED PER 210.62,220.12 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-09 |
Time |
14:42 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-06-09 |
Time |
14:42 |
Sent To |
FIRE |
|
| Notes |
| 2005-06-09 00:00:00 | ******* UNSAT ****** | | | | | | 1)NOTE: PLEASE SEE AN ELECTRICAL PERMIT | | | IS BEING APPLIED FOR , YET NO ELECTRICAL | | | PLANS/DRAWINGS WERE SUBMIT FOR SCOPE OF | | | WORK. | | | | | | 2)NOTE: PLEASE PROVIDE INFORMATION ON | | | LIGHTING ETC WHICH MAY BE REQUIRED FOR | | | MEANS OF EGRESS, EM LT, EXT LTS ETC. | | | LS 101 5-8, 700.12E ETC. | | | SHOW ALL NEW TO BE INSTALLED ETC. | | | | | | PLEASE SEE DUE TO NO INFORMATION BEING | | | SUBMITTED, A COMPLETE REVIEW CAN NOT BE | | | DONE AT THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-03 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-03 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-06-27 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-06-27 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2005-06-27 00:00:00 | **********DENIED************ | | | | | | PLANS/DRAWINGS MUST CONTAIN THE PRINTED | | | NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR PLANS AND DESIGN. FBC | | | 104.2.1 OTHERWISE CODE COMPLIANCE FOR | | | LIFE SAFETY. | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-06-10 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-06-10 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2005-06-10 00:00:00 | ****DENIED**** | | | | | | 1) PLEASE SUBMIT DRAWINGS ILLUSTRATING | | | SCOPE OF WORK. A FIRE REVIEW FOR LIFE | | | SAFETY CAN'T BE DONE AT THIS TIME. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 805-6722 OR 835-2951 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-26 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-26 |
Time |
18:35 |
Sent To |
E |
|
| Notes |
| 2005-09-26 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-21 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-21 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2005-07-22 00:00:00 | TO "COMM" BD#32 | | 2005-07-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2005-06-23 00:00:00 | TO "COMM" BD#5 | | 2005-06-20 00:00:00 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-06 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-06 |
Time |
14:23 |
Sent To |
B |
|
| Notes |
| 2005-06-06 00:00:00 | TO 'MISC' BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-06-08 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2005-05-24 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2005-05-24 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|