Plan Review Details - Permit 05051371
Plan Review Stops For Permit 05051371
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-06-15 Cont ID  
Sent By lsmith Date 2005-06-15 Time 15:49 Rev Time 0.75
Received By lsmith Date 2005-06-15 Time 15:49 Sent To  
Notes
2005-06-15 00:00:00BUILDING PLAN REVIEW: PROVISO
  
 VALUE OF PERMIT HAS BEEN ADJUSTED PER
 MARSHALL/SWIFT. ADDITIONAL FEES ARE DUE
 BEFORE A PERMIT CAN BE ISSUED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-07 Cont ID  
Sent By btrobaug Date 2005-07-07 Time 11:49 Rev Time 0.50
Received By btrobaug Date 2005-07-07 Time 11:45 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-05-31 Cont ID  
Sent By btrobaug Date 2005-05-31 Time 10:47 Rev Time 0.33
Received By btrobaug Date 2005-05-31 Time 10:46 Sent To P
Notes
2005-05-31 00:00:00PLEASE SUBMIT DETAILS FOR THE PANEL
 SHOWN ON THE SCHEMATIC, FEEDER AND CONDU
 IT SIZE AND TYPE, PANEL RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC.
 IF AN ELECTRIC HEATER IS TO BE INSTALLED
 PLEASE SUBMIT CALCULATIONS FOR THE MAIN
 SERVICE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-05-19 Cont ID  
Sent By spalmer Date 2005-05-19 Time 11:59 Rev Time 0.15
Received By spalmer Date 2005-05-19 Time 11:59 Sent To  
Notes
2005-05-19 00:00:00OKAY PER NEELAM FATIMA

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-07 Cont ID  
Sent By adarroug Date 2005-07-07 Time 10:51 Rev Time 0.00
Received By adarroug Date 2005-07-07 Time 10:51 Sent To E
Notes
2005-07-07 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-27 Cont ID  
Sent By adarroug Date 2005-05-27 Time 16:15 Rev Time 0.00
Received By adarroug Date 2005-05-27 Time 16:15 Sent To E
Notes
2005-05-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-20 Cont ID  
Sent By adarroug Date 2005-05-20 Time 16:06 Rev Time 0.00
Received By adarroug Date 2005-05-20 Time 16:06 Sent To Z
Notes
2005-05-20 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-06-08 Cont ID  
Sent By pschmitz Date 2005-06-08 Time 14:07 Rev Time 0.00
Received By pschmitz Date 2005-06-08 Time 14:07 Sent To B
Notes
2005-06-08 00:00:00BSCK FLOW PREVENTER INSTALLED PRIOR TO
 WORK ON POOL.

Review Stop Z ZONING
Rev No 1 Status P Date 2005-05-27 Cont ID  
Sent By mmclean Date 2005-05-27 Time 11:29 Rev Time 0.00
Received By mmclean Date 2005-05-27 Time 11:29 Sent To I
Notes
2005-05-27 00:00:00NO ROOF FOR DECK. MUST HAVE A MIN OF 5FT
 ON THE SIDES AND REAR.