| Plan Review Stops For Permit 05051299 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-07-28 |
Time |
09:09 |
Rev Time |
1.00 |
| Received By |
mjacobs |
Date |
2005-07-28 |
Time |
08:45 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-07-14 |
Time |
14:26 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2005-07-14 |
Time |
11:38 |
Sent To |
PC |
|
| Notes |
| 2005-07-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05051299 | | | ADD:8249 HERITAGE CLUB DR. | | | CONT:PELLICO ENG & CONST. | | | TEL: (561)422-1001 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW:2ND | | | ACTION:DENIED | | | | | | 1)ALL RECORDED DOCUMENTS MUST BE | | | LEGIBLE.HOWEVER,THE PRODUCT APPROVALS | | | SUBMITTED ARE ILLIGABLE AND OUTDATED. | | | PLEASE VISIT THE WEBSITE AND SEE THE | | | UPDATED PRODUCT APPROVALS. | | | (WWW.FLORIDABUILDING.ORG.) GO TO PRODUCT | | | SEARCH. | | | | | | 2) THE SEAL ON THE PLANS HAS TO BE CLEAR | | | WITH ALL THE INFORMATION OF THE PERSON | | | SEALING THE PLANS.FOR MORE INFORMATION | | | SEE F.A.C.CH. 61G1-16. INREFERENCE TO | | | PRINTED NAME/ADDRESS/PHONE NUMBER ETC. | | | DRAWINGS NEED TO BE SEALED CLEARLY. | | | | | | 3) THE SIGNATURE ON THE PLANS VARIES. | | | PLEASE SUBMIT A SIGNED,SEALED AND | | | NOTERIZE LETTER WITH THE SIGNATURE OF | | | THE PERSON WHO IS SEALING THESE | | | DRAWINGS. | | | | | | 4) ON SHEET A-1 THERE IS A GLUED ON | | | DETAIL.THIS IS NOT ACCEPTABLE. ONLY THE | | | PERSON WHO DESIGNAND DRAW THESE PLANS | | | IS ALLOWED TO MAKE CHANGES TO THE PLANS. | | | PLEASE DELETE THIS FROM THE PLANS. | | | | | | 5)IS THE NEW DOOR THE SAME WIDTH AS THE | | | WINDOW IT WILL REPLACE? ALSO, DOES THE | | | HEADDER HEIGHT HAS TO BE ALTERDE TO | | | ACCOMIDATE THE NEW DOOR? IF SO PLEASE | | | SHOW IN DETAIL HOW THIS WORK WILL BE | | | DONE. | | | | | | 6) WHAT TYPE OF BEAM IS TIED INTO THE | | | EXISTING COLUM AT THE WEST ELEVATION? IS | | | IT WOOD BEAM/CONCRETE TIE BEAM OR A | | | U-LENTIL? PLEASE CLARIFY. ON SHEET A-5 | | | DETAILS 1 AND 2 SHOWS DIFFERENT TYPES OF | | | BEAMS. ALSO SHOW THE SIZE OF THE | | | EXISTING BEAM. | | | | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-21 |
Time |
14:46 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2005-06-21 |
Time |
10:39 |
Sent To |
PC |
|
| Notes |
| 2005-06-21 00:00:00 | 1) BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE ACTUAL PERMIT PLANS | | | MUST BE STAMPED BY THAT OFFICE, AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION.PLEASE CALL (561) | | | 233-5025 FOR MORE INFORMATION. | | | | | | 2) SUBMIT PRODUCT APPROVALS FOR THE | | | FRENCH DOORS AND SHUTTERS IF THE WINDOWS | | | ARE NOT INPACT WINDOWS. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | (IF YOU FIND THAT THE QUOTED WEB PAGE IS | | | NO LONGER AVAILABLE, PLEASE INFORM THE | | | PLAN REVIEWER) | | | | | | 3) SEPERATE PERMIT IS REQUIRED FOR | | | SCREEN ENCLOSURE. | | | | | | 4) SHOW FRAMING DETAIL FOR NEW FRENCH | | | DOOR WHICH WILL REPLACE THE EXISTING | | | WINDOW. | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-31 |
Time |
17:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-31 |
Time |
16:57 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-27 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-27 |
Time |
14:59 |
Sent To |
B |
|
| Notes |
| 2005-07-27 00:00:00 | TO "MJACOBS" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-12 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-12 |
Time |
14:31 |
Sent To |
B |
|
| Notes |
| 2005-07-12 00:00:00 | TO "MJACOBS" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-28 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-28 |
Time |
16:06 |
Sent To |
Z |
|
| Notes |
| 2005-06-28 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-27 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-27 |
Time |
16:10 |
Sent To |
E |
|
| Notes |
| 2005-05-27 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-21 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-05-20 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2005-05-20 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-06-02 |
Time |
15:21 |
Rev Time |
0.50 |
| Received By |
rregueir |
Date |
2005-06-02 |
Time |
15:18 |
Sent To |
P |
|
| Notes |
| 2005-06-02 00:00:00 | PROVISO: BALANCED R/A REQUIRED IN NEW | | | OFFICE PER FBC,M 601.4 | | | | | | SEPARATE PERMIT APPLICATION REQUIRED FOR | | | MECHANICAL. | | | | | | RONALD J REGUEIRO | | | 561-805-6734 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-28 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-06-07 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2005-06-07 00:00:00 | NO PLUMBING SHOWN ON ADDITION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-11 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-11 |
Time |
14:16 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-27 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-27 |
Time |
11:06 |
Sent To |
I |
|
| Notes |
| 2005-05-27 00:00:00 | DENIED, | | | 1. MUST PROVIDE SETBACKS OF THE EXISTING | | | & NEW ADDITION ON 2 COPY OF SITEPLANS. | | | 2. MUST PRORIVDE REAR/FRONT/SIDE | | | SETBACKS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|