| Plan Review Stops For Permit 05051272 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-28 |
Time |
07:07 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2005-08-28 |
Time |
06:58 |
Sent To |
PC |
|
| Notes |
| 2005-08-28 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05051272 | | | ADD: 735 PALM ST | | | CONT: POOLS, SPAS & BEYOND | | | TEL: (561)722-9386 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | POOL RESTAMP | | | BUILDING PROVISO: | | | | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE | | | PROVIDED WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH | | | 424.2.17.1.14. | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | | | | 2)13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-07-07 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2005-07-07 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-06-08 |
Time |
16:29 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-06-08 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2005-06-08 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | | | | 1.104.6.5 BUILDING PERMIT VALUATION. | | | IF IN THE OPINION OF THE BUILDING | | | OFFICIAL THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL OR PLUMBING | | | SYSTEMS APPEARS TO BE UNDERESTIMATED ON | | | THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW | | | DETAILED ESTIMATES AND/OR BONA FIDED | | | SIGNED CONTRACTS (EXCLUDING LAND VALUE) | | | TO MEET THE APPROVAL OF THE BUILDING | | | OFFICIAL. FOR PERMITTING PURPOSES, | | | VALUATION FOR BUILDINGS AND SYSTEMS | | | SHALL BE FOUND IN MARSHALL AND SWIFT OR | | | THE SOUTHERN BUILDING CODE CONGRESS | | | INTERNATIONAL VALUATION TABLES, LATEST | | | EDITION, AND SHALL BE BASED ON TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISH, NORMAL SITE WORK (EXCAVATION AND | | | BACKFILL FOR BUILDINGS), ARCHITECTURAL | | | AND DESIGN FEES, OVERHEAD AND PROFIT, | | | EXCLUDING ONLY LAND VALUE. | | | | | | SUBMIT A SIGNED CONTRACT TO VERIFY VALUE | | | OF POOL. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-08-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-25 |
Time |
09:29 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-08-25 |
Time |
09:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-07-08 |
Time |
09:40 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-07-08 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-06-22 |
Time |
21:57 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-06-22 |
Time |
21:57 |
Sent To |
P |
|
| Notes |
| 2005-06-22 00:00:00 | WHAT SIZE IS THE BRANCH CIRCUIT THAT | | | FEEDS THE POOL PANEL? | | | | | | WHAT SIZE WIRE WILL BE USED TO FEED POOL | | | PANEL? | | | | | | WHAT SIZE BREAKER WILL BE USED TO FEED | | | POOL PANEL? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-05-31 |
Time |
13:16 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-05-31 |
Time |
13:16 |
Sent To |
P |
|
| Notes |
| 2005-05-31 00:00:00 | NEED TO SHOW SIZE OF SERVICE | | | | | | NEED TO SHOW BRANCH CIRCUIT SIZE FEEDING | | | POOL PANEL | | | | | | SHOW PANEL SCHEDULE FOR HOUSE PANEL | | | | | | | | | JAKE LEAHY | | | | | | 644-7291 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
12:23 |
Sent To |
E |
|
| Notes |
| 2005-06-20 00:00:00 | TO JL DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-26 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-26 |
Time |
11:38 |
Sent To |
E |
|
| Notes |
| 2005-05-26 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-19 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-19 |
Time |
10:54 |
Sent To |
Z |
|
| Notes |
| 2005-05-19 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-08-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-25 |
Time |
07:46 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-25 |
Time |
07:46 |
Sent To |
E |
|
| Notes |
| 2005-08-25 00:00:00 | RE-STAMP ON COPY OF PLANS FOR JOB. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-30 |
Time |
10:10 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-06-30 |
Time |
10:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-07 |
Time |
17:45 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-06-07 |
Time |
17:45 |
Sent To |
B |
|
| Notes |
| 2005-06-07 00:00:00 | DENIED; | | | POOL SCHMATIC SHOWS MORE EQUIPMENT AND | | | PIPING THAN THE POOL DATA & EQUIPMENT & | | | CRITERIA SHOWS. NO VAC LINE NO HEATER | | | INFORMATION, AND ROSETTIES. MAIN DRAIN | | | RELIEF VENTS ARE 1 1/2 OR 1'. PLEASE | | | PROVIDE HEATER INFORMATION AND SHOW VAC | | | LOCK TO BE USED. | | | PLUMBING PLAN REVIEW BY | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-25 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-25 |
Time |
15:41 |
Sent To |
I |
|
| Notes |
|
|