Plan Review Details - Permit 05051060
Plan Review Stops For Permit 05051060
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-11-21 Cont ID  
Sent By jwitmer Date 2005-11-21 Time 16:31 Rev Time 0.77
Received By jwitmer Date 2005-11-21 Time 16:31 Sent To PC
Notes
2005-11-21 00:00:00REVISION DATED 11-07-05 OK JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-07-19 Cont ID  
Sent By jwitmer Date 2005-07-19 Time 18:50 Rev Time 0.00
Received By jwitmer Date 2005-07-19 Time 18:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-20 Cont ID  
Sent By jwitmer Date 2005-06-20 Time 07:40 Rev Time 0.55
Received By jwitmer Date 2005-06-20 Time 07:31 Sent To  
Notes
2005-07-19 00:00:001) 704.2.1.4 CORRIDOR PARTITIONS,
 SMOKE STOP PARTITIONS, HORIZONTAL EXIT
 PART- ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 TABLE 803.3
 MINIMUM INTERIOR FINISH CLASSIFICATION
  
 R- CLASS C INTERIOR FINISH MATERIALS MAY
 BE USED WITHIN A DWELLING UNIT.
 CLASS C INTERIOR FINISH.FLAMESPREAD
 76-200, SMOKE DEVELOPED 0-450.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-11-17 Cont ID  
Sent By dpalmer Date 2005-11-17 Time 14:55 Rev Time 0.00
Received By dpalmer Date 2005-11-17 Time 14:15 Sent To  
Notes
2005-11-17 00:00:00REDLINED PLANS 2ND TIME, ALL REDLINEDS
 SHALL BE CORRECTED IF PLANS COME BACK
 WITH ANY OTHER CHANGES.
  
 ALL KITCHEN COUNTERSPACE RECEPTS ARE TO
 GFI / GFI PROTECTED. 210.8A6
 ALL MUST BE 20A, #12, 210.11C1,220.16,
 210.52.
  
 ALL BATH GFI'S ARE TO BE 20A, #12
 210.11C3,210.52D

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-07-20 Cont ID  
Sent By dpalmer Date 2005-07-20 Time 10:45 Rev Time 0.30
Received By dpalmer Date 2005-07-20 Time 10:45 Sent To  
Notes
2005-07-20 00:00:00REDLINED PLANS.
  
 ALL KITCHEN COUNTERSPACE RECEPTS ARE TO
 GFI / GFI PROTECTED. 210.8A6
 ALL MUST BE 20A, #12, 210.11C1,220.16,
 210.52.
  
 ALL BATH GFI'S ARE TO BE 20A, #12
 210.11C3,210.52D

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-06-09 Cont ID  
Sent By dpalmer Date 2005-06-09 Time 11:50 Rev Time 0.25
Received By dpalmer Date 2005-06-09 Time 11:50 Sent To  
Notes
2005-06-09 00:00:00********* UNSAT *******
  
 1)NOTE: PLEASE SHOW RECEPTS WHICHWILL
 BE REQUIRED TO MEET 210.52C1-5 FOR
 KITCHEN COUNTERSPACE ARE.
 PLEASE ALSO INDICATE AS GFI/GFI
 PROTECTED PER 210.8A6
  
 2)NOTE: PLEASE SEE NOTE ON PLANS
 MENTIONS TO REPLACE RECEPTS TO GFI'S
 KIT/BATHS.
 PLEASE SHOW THESE LOCATIONS.
 210.52D
  
 3)NOTE: PLEASE SEERAISED SEAL BY ARCH
 MUST BE CLEAR AND VISABLE WITH ALL
 INFORMATION REQUIRED ONSAID SEAL PER
 FAC 61G1-16.003 FS 481.025
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-06-23 Cont ID  
Sent By nmccray Date 2005-06-23 Time 10:54 Rev Time 0.00
Received By nmccray Date 2005-06-23 Time 10:54 Sent To  
Notes
2005-06-23 00:00:00PROVISO
 INTERIOR FINISH FOR WALLS AND CEILINGS
 SHALL BE CLASS A, CLASS B, OR CLASS C.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-14 Cont ID  
Sent By adarroug Date 2005-11-14 Time 17:55 Rev Time 0.00
Received By adarroug Date 2005-11-14 Time 17:53 Sent To  
Notes
2005-11-14 00:00:00TO "BOB"#5

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-13 Cont ID  
Sent By adarroug Date 2005-07-13 Time 10:44 Rev Time 0.00
Received By adarroug Date 2005-07-13 Time 10:44 Sent To  
Notes
2005-07-19 00:00:00TO "COMM" BD#20
2005-07-13 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-24 Cont ID  
Sent By pkrauss Date 2005-06-24 Time 16:25 Rev Time 0.00
Received By pkrauss Date 2005-05-17 Time 16:04 Sent To  
Notes
2005-06-02 00:00:00TO "COMM" BD#1
2005-05-17 00:00:00IN INCOMING AWAITING SPACE ON "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-06-24 Cont ID  
Sent By pkrauss Date 2005-06-24 Time 16:24 Rev Time 0.20
Received By pkrauss Date 2005-06-24 Time 16:24 Sent To  
Notes
2005-06-24 00:00:00NO MECHANICAL CONTRACTOR OR WORK
 INDICATED WITH PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-07-27 Cont ID  
Sent By pschmitz Date 2005-07-27 Time 08:36 Rev Time 0.00
Received By pschmitz Date 2005-07-27 Time 08:36 Sent To B
Notes
2005-07-27 00:00:00REPLACE FIXTURES ONLY.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-06-18 Cont ID  
Sent By pschmitz Date 2005-06-18 Time 10:15 Rev Time 0.00
Received By pschmitz Date 2005-06-18 Time 10:15 Sent To M
Notes
***NONE***