| Plan Review Stops For Permit 05051005 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-09-23 |
Time |
17:02 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2005-09-23 |
Time |
17:02 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-08-02 |
Time |
09:04 |
Rev Time |
2.75 |
| Received By |
mjacobs |
Date |
2005-08-02 |
Time |
06:50 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-07-22 |
Time |
16:26 |
Rev Time |
2.50 |
| Received By |
mjacobs |
Date |
2005-07-22 |
Time |
08:38 |
Sent To |
PC |
|
| Notes |
| 2005-07-22 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05051005 | | | ADD:743 BISCAYNE DR. | | | CONT:STEPHEN ROY | | | TEL: (561)248-9516 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 2ND | | | ACTION:DENIED | | | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) FBC 13-103.1.2 BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHETECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | 3) WHICH ONE OF THE DECK WILL BE | | | CONCRETE? ONE OF THE PRODUCT APPROVAL | | | SUBMITTED REFERS TO A CONCRETE DECK. | | | ALSO NONE OF THE PRODUCT APPROVALS HAVE | | | THE STATE COVER SHEETS. ALL PRODUCTS | | | SUBMITTED NEEDS THE MATCHING CURRENT | | | STATE COVER SHEET. I AM SUPPLYING YOU | | | WITH AN EXAMPLE OF THE STATE COVER SHEET | | | WITH ONE OF THE PRODUCT YOU SUBMITTED, | | | SO YOU CAN SEE WHAT I AM SPEAKING OF. | | | | | | 4) THE PRODUCT APPROVALS SUBMITTED FOR | | | THE METAL ROOF NEEDS A STATE APROVAL | | | REPORT ALONG WITH THE STATE COVER | | | SHEETS. THE MANUFACTURE INFORMATION | | | ALONE IS NOT ACCEPTABLE. ALSO PLEASE SEE | | | FBC.1507.6.2 DECK SLOPE. METAL ROOF | | | SHINGLES SHALL NOT BE INSTALLED ON ROOF | | | SLOPES BELOW 3:12. | | | 1507.6.3 UNDERLAYMENT. UNDERLAYMENT | | | SHALL CONFORM WITH ASTM D 226, TYPE | | | I. | | | 5) IS THE CARRAGE HOUSE GETTING A NEW | | | FLAT ROOF? OR IS THE ROOF EXISTING? | | | PLEASE CLARIFY. IF IT IS A NEW ROOF, | | | SUPPLY PRODUCT APPROVAL FOR THE FLAT | | | ROOF.WHEN SUBMITTING PRODUCT APPROVALS | | | FOR THE FLAT ROOF, PLEASE KNOW THAT | | | SYSTEMS THAT STATES GENERAL LIMITATIONS | | | #9 WITH -PSF LESS THAT -89PSF IS NOT | | | ACCEPTABLE. | | | | | | 6) FBC 1606.2.5.GENERAL LIMITATION | | | #9 PROHIBITS RATIONAL ANALYSIS OR | | | EXTRAPOLATION TO ENHANCE THE UPLIFT | | | PRESSURE AT PERIMETER AND CORNER AREAS | | | BY REDUCING THE FASTENER SPACING IN | | | THESE AREAS.EITHER SELECT AN | | | ALTERNATIVE SYSTEM (OR PRODUCT APPROVAL) | | | THAT DOES NOT CITE GENERAL LIMITATION | | | #9.ALTERNATIVELY IF THE SELECTED | | | SYSTEM DOES CITE GENERAL LIMITATION #9, | | | IT MUST HAVE A MAXIMUM DESIGN PRESSURE | | | THAT EXCEEDS THE PRESSURE IN ROOF ZONE 3 | | | (TYPICALLY -89 PSF FOR MEAN ROOF HEIGHT | | | OF 30 FEET OR LESS). | | | | | | 7) ON SHEET A.5, IF DOOR 'E' WILL BE | | | USED PLEASE SUPLY PRODUCT APPROVAL FOR | | | THAT DOOR OR YOU MAY APPLY FOR LOCAL | | | PRODUCT APPROVAL. SEE APPLICATION IN | | | PACKAGE. | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-27 |
Time |
10:30 |
Rev Time |
4.50 |
| Received By |
mjacobs |
Date |
2005-06-27 |
Time |
06:51 |
Sent To |
PC |
|
| Notes |
| 2005-06-27 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05051005 | | | ADD:743 BISCAYNE DR. | | | CONT:ROY STEPHEN | | | TEL: (561)659-5683 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION:DENIED | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 3) PROVIDE ENERGY CALCULATIONS AND | | | EQUIPMENT SIZING CALCULATIONS (MANUAL J) | | | AS REQUIRED BY THE 2001 FLORIDA ENERGY | | | EFFICIENTCY CODE FOR BUILDING CONSTRUC- | | | TION. | | | | | | 4) PLEASE PROVIDE PRODUCT APPROVALS FOR | | | THE FOLLOWING.NEW DOORS/WINDOWS,ROOFING | | | MATERIALS, LENTIL PRODUCT APPROVALS | | | SUBMITTED WITH PERMIT APPLICATION AFTER | | | OCTOBER 1, 2003 ARE REQUIRED TO COMPLY | | | WITH THE FLORIDA PRODUCT APPROVAL | | | SYSTEM. FOR INFORMATION PLEASE SEE THE | | | STATE WEBSITE ATWWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE | | | REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5) PLEASE SHOW A DETAIL DRAWING FOR THE | | | NEW PARAPET CONSTRUCTION. | | | | | | 6) FBC 2309.6ACCESS TO ATTIC SPACE | | | EACH ATTIC SPACE WITH A CLEAR HEIGHT OF | | | 24" OR GREATER SHALL BE PROVIDED WITH AN | | | INTERIOR ATTIC ACCESS OPENING NOT LESS | | | THAN 20"X 36". | | | | | | 7)THE SURVEY SUBMITTED STATES THAT THIS | | | LOCATION IN A 'C' ZONE HOWEVER ON THE | | | PLANS SHEET A.O. STATES FLOOD ZONE AS | | | 'A5'. ACCORDING TO OUR FLOOD MAP, THE | | | LOCATION IS IN A 'C' ZONE.PLEASE CHANGE | | | PLANS TO MATCH. | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-31 |
Time |
12:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-31 |
Time |
12:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-03-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-15 |
Time |
11:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-15 |
Time |
11:38 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-10 |
Time |
13:57 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-09-10 |
Time |
13:35 |
Sent To |
M |
|
| Notes |
| 2005-09-10 00:00:00 | REDLINED PLANS, | | | PANEL "C" SHALL NOT BE LOCATES IN A | | | "STORAGE RM". | | | 240.24D,110.26,408.7 | | | THIS RM AS SHOWN IS ONLY TO BE A | | | ELECTRICAL / EMCH RM OR PANEL IS TO BE | | | MOVED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-26 |
Time |
12:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-26 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-12 |
Time |
12:30 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-12 |
Time |
12:15 |
Sent To |
P |
|
| Notes |
| 2005-07-12 00:00:00 | | | | THE ARCHITECT MUST SIGN AND SEAL BOTH | | | SETS OF PLANS. 61G1-16.003 FAC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-31 |
Time |
14:11 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-27 |
Time |
17:48 |
Sent To |
M |
|
| Notes |
| 2005-05-31 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE THE LOCATION OF THE SERVICE | | | SO THAT DISCONNECT REQUIREMENTS CON BE | | | REVIEWED. | | | | | | 2} SHOW LOCATION OF THE PANEL SERVING | | | THE REC ROOM, DISCONNECTING MEANS AND | | | GROUNDING. | | | | | | 3} PLEASE PUT ROOM DESIGNATIONS ON THE | | | ELECTRICAL FLOOR PLANS. | | | | | | 4} THE PANEL DESIGNATION ON THE RISER | | | AND PANEL SCHEDULE DO NOT CCORRELATE. | | | "C" & "G". | | | | | | 5} SEE 210.52(C)(2) FOR ISLAND | | | RECEPTACLE REQUIREMENTS.INDICATE | | | COMPLIANCE ON PLANS. | | | | | | 6} REC ROOM KITCHEN COUNTERTOP | | | RECEPTACLE SPACING MUST COMPLY WITH | | | 210.52(C)(1). | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-25 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-25 |
Time |
11:01 |
Sent To |
E |
|
| Notes |
| 2006-10-25 11:01:53 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-15 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-15 |
Time |
10:24 |
Sent To |
E |
|
| Notes |
| 2006-03-15 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-12 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-12 |
Time |
16:33 |
Sent To |
B |
|
| Notes |
| 2005-09-12 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-08 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-08 |
Time |
09:01 |
Sent To |
E |
|
| Notes |
| 2005-09-08 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-26 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-26 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2005-08-01 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-07 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-07 |
Time |
12:42 |
Sent To |
E |
|
| Notes |
| 2005-07-07 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
09:15 |
Sent To |
E |
|
| Notes |
| 2005-05-24 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-27 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-05-16 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2005-05-16 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-12 |
Time |
11:12 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-09-12 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2005-09-12 00:00:00 | *** PROVISO *** | | | | | | 1) A GAS PERMIT IS REQUIRED FOR GAS | | | LINES. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL, | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-07-20 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-07-20 |
Time |
17:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-15 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-15 |
Time |
13:19 |
Sent To |
P |
|
| Notes |
| 2005-06-15 00:00:00 | PLAN DENIED | | | 1) PLEASE SUPLY TWO SETS OF ENERGY | | | CALCULATIONS,AND MANUAL (J) WITH PLANS | | | 2) REFER TO SECTION 601.4 2001 | | | FBC(M)BALANCED RETURN AIR. | | | 3) REFER TO SECTION 307.2.3 AUXILIAEY | | | DRAIN PANS. | | | 4) PLEASE SHOW TYPE OF DOORS ON PLAN FOR | | | WASHER & DRYER | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-07-20 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-07-20 |
Time |
10:22 |
Sent To |
M |
|
| Notes |
| 2005-07-20 00:00:00 | PROVISO: | | | SEE NOTES ON SHT P-1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-06-18 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-18 |
Time |
05:12 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-06-18 |
Time |
05:12 |
Sent To |
B |
|
| Notes |
| 2005-06-18 00:00:00 | PLUMBING PLAN REVIEW DENIED FBC 2001 | | | (1) SEC 909 WET VENTING: | | | MASTER BATH, TUB, SHOWER NOT VENTED. | | | CONNECT THE LAV WET VENT TO TUB, SHOWER | | | FIXTURE DRAINS. | | | (2)MINIMUM FACILITES REQUIRED: TAB 403.1 | | | SHOW LOCATION OF THE WASHING MACHINE | | | DRAIN, AND H/C WATER CONNECTIONS, | | | (3)SEPERATE PERMIT FOR PLUNGE POOL. | | | (4) LOCAL ORD #2853-95 | | | BACK FLOW PREVENTER REQUIRED ON WATER | | | SERVICE FOR PLUNGE POOL. | | | END OF COMMENTS. | | | QUESTIONS: PAUL SCHMITZ 561-805-6692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-23 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-23 |
Time |
11:16 |
Sent To |
I |
|
| Notes |
| 2005-05-23 00:00:00 | APPROVING FOR ADDITION ONLY. |
|
|