| Plan Review Stops For Permit 05050996 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-07-13 |
Time |
13:36 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-07-12 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-06-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-06-03 |
Time |
13:41 |
Rev Time |
3.25 |
| Received By |
alange |
Date |
2005-06-03 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2005-06-03 00:00:00 | DENIED | | | | | | 1.SUBMIT MANUFACTURERS SPECIFICATIONS | | | FOR BUILT IN BBQ.CHECK TO SEE IF BBQ | | | CAN OPERATE UNDER COMBUSTABLE | | | CONSTRUCTION. | | | | | | 2.SHOW BUCK DETAIL OFFERING FULL | | | SUPPORT OF THE FRAME.FBC 1707.4.4.2 | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-04-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-20 |
Time |
12:18 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-04-20 |
Time |
12:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-23 |
Time |
17:43 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-02-23 |
Time |
17:41 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-08 |
Time |
07:43 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-02-08 |
Time |
07:15 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-27 |
Time |
07:22 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-06-27 |
Time |
07:13 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-26 |
Time |
16:12 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-26 |
Time |
15:41 |
Sent To |
M |
|
| Notes |
| 2005-05-26 00:00:00 | | | | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | | | | 1} INDICATE THE LOCATION OF PANEL | | | "B"&"C". | | | | | | 2} INDICATE LOCATION OF OVERCURRENT | | | PROTECTION FOR PANELS "A" & "B". | | | | | | 3} THE OCP FOR CIRCUITS 16,17 PANEL "A", | | | 12,13,14,15 PANEL "B" IS TOO LARGE FOR | | | THE CONDUCTORS PER 210.16. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-15 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-15 |
Time |
15:10 |
Sent To |
E |
|
| Notes |
| 2006-04-15 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-21 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-21 |
Time |
08:29 |
Sent To |
E |
|
| Notes |
| 2006-02-21 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-07 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-07 |
Time |
15:19 |
Sent To |
E |
|
| Notes |
| 2006-02-07 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-24 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-24 |
Time |
16:33 |
Sent To |
E |
|
| Notes |
| 2005-06-24 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
18:07 |
Sent To |
Z |
|
| Notes |
| 2005-05-24 00:00:00 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
08:13 |
Sent To |
E |
|
| Notes |
| 2005-05-24 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-03 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-16 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2005-05-16 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-06 |
Time |
13:38 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2005-07-06 |
Time |
13:38 |
Sent To |
B |
|
| Notes |
| 2005-07-06 00:00:00 | NO MECHANICAL PLAN SUBMITTED FOR REVIEW. | | | ENERGY AND MANUAL J CALCS SUBMITTED. | | | COUSINS AIR IS INDICATED AS THE A/C | | | CONTRACTOR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-05-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-05-29 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-05-31 |
Time |
13:18 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-05-31 |
Time |
13:18 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-06-01 |
Time |
19:17 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-27 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-27 |
Time |
10:19 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-20 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-20 |
Time |
16:36 |
Sent To |
I |
|
| Notes |
| 2005-05-29 00:00:00 | NO PLANS | | 2005-05-20 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO COPY OF SURVEY | | | SHOWING THE NSF WITH SETBACKS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|